Agilent Technologies AdvanceBio Gly-X Technology | N-glycan Analysis
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies AdvanceBio Gly-X Technology | N-glycan Analysis

Agilent Technologies AdvanceBio Gly-X Technology | N-glycan Analysis — Biopharma hplc analysis.

The AdvanceBio Gly-X Technology is a kit-based N-glycan sample preparation and analysis workflow, not a standalone instrument. It combines rapid enzymatic deglycosylation and fluorescent labeling with HILIC-UHPLC separation and fluorescence or MS detection. This modification is distinguished by its 2-AB Express and InstantPC labeling options, enabling a total workflow time of approximately 2 hours.

Agilent Technologies Glycan Preparation Series — Model Comparison & Selection

Model Mass rangeNozzle voltage, VSheath gas flow, liter/minuteFluorescence detector maximum data rate, HzGlycan sample preparation time, hPumping speed, m³/h
AdvanceBio Gly-X Technology | N-glycan Analysis Current 600...3,00050010741—
Sialic Acid Profiling and Quantitation Kits | Analysis —1800127412.4×10⁻⁵

Full specifications

Core Performance & Functional Specifications
Column temperature 40 °C
Fluorescence Detector Maximum Data Rate 74 Hz
Glycan Sample Preparation Time 1 hour
Sheath Gas Flow 10 L/min
Denature time (GlykoPrep with 2-AB) mfr 5 min
Deglycosylation time (GlykoPrep with 2-AB) mfr 15...60 min
Dry down time (GlykoPrep with 2-AB) mfr 30...60 min
Labeling time (GlykoPrep with 2-AB) mfr 60 min
Cleanup time (GlykoPrep with 2-AB) mfr 15...30 min
Total workflow time (GlykoPrep with 2-AB) mfr 3.5 hours
Denature time (Gly-X with 2-AB Express) mfr 3 min
Deglycosylation time (Gly-X with 2-AB Express) mfr 5 min
Labeling time (Gly-X with 2-AB Express) mfr 60 min
Cleanup time (Gly-X with 2-AB Express) mfr 10...15 min
Total workflow time (Gly-X with 2-AB Express) mfr 2 hours
Fluorescence detection excitation/emission mfr 360 nm
Cleanup time mfr 10...15 minutes
Protein amount per preparation mfr 40 μg
Dimensions, Weight & Mechanical Design
Mass range 600...3,000
Electrical, Power & Drive Specifications
Nozzle Voltage 500 V
Vcap mfr 3000 V
Fragmentor mfr 120 V
Skimmer mfr 65 V

Description

Construction and Positioning

Workflow Behavior and Media

Installation and Operation

Integration & Operating Notes

Process Limits
Do not exceed 40 µg protein per preparation

The protocol is validated for 40 µg protein per preparation; exceeding this load may overload the cleanup resin and reduce labeling efficiency, leading to incomplete glycan profiles or inconsistent fluorescence response.

Application Note 5994-1348EN
Control & I/O
Maintain precise temperatures for each enzymatic step

Denaturation requires 90 °C, deglycosylation 50 °C, and labeling 65 °C for 2-AB Express or 50 °C for InstantPC. Temperature deviations can cause incomplete deglycosylation or label degradation, affecting glycan quantitation.

Application Note 5994-1348EN
Maintenance
Use only Gly-X kits within their shelf life

The Gly-X kits (p/n GX96-IPC and GX96-2AB) are consumables with defined expiry; using expired kits may result in reduced enzyme activity or label degradation, compromising glycan profiles. Store according to the kit instructions.

Application Note 5994-1348EN

Selection & Integration Q&A

When should I choose the Gly-X Technology over the GlykoPrep-plus with AssayMAP Bravo?

Choose Gly-X for a rapid, manual or semi-automated workflow with 2-hour total time and 40 µg protein per prep. Choose GlykoPrep-plus with AssayMAP Bravo when full automation and higher throughput are required, accepting a longer 3.5-hour workflow.

What maintenance and consumables are required beyond the base Gly-X kit?

The base kit includes enzymes, labels, and cleanup plates, but requires additional consumables such as pipette tips, microcentrifuge tubes, and LC mobile phases (e.g., AdvanceBio Ammonium Formate). Regular maintenance of the LC/FLD/MS system per manufacturer schedules is necessary.

Dimensional Drawings & Technical Documentation

Technical documentation