Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Sialic Acid Profiling and Quantitation Kits | Analysis

Agilent Technologies Sialic Acid Profiling and Quantitation Kits | Analysis — Biopharma hplc analysis with Pumping speed 2.4×10⁻⁵ m³/h.

The AdvanceBio Sialic Acid Profiling and Quantitation workflow (kit GKK-407) is a 96-well-plate sample-prep and 10-minute RP-UHPLC/FLD method for sialic acid release, DMB labeling and quantitation in biotherapeutic glycoproteins. It runs on a 1290 Infinity II LC with Infinity multisampler and a 120 column, detected by FLD or optional 6545 LC/Q-TOF MS. It is the sialic-acid-specific member of the AdvanceBio glycan workflow family, distinct from amino-acid, Gly-X, HIC and EC-C18 siblings.

Pumping speed
2.4×10⁻⁵ m³/h

Agilent Technologies Glycan Preparation Series — Model Comparison & Selection

Model Mass rangeNozzle voltage, VSheath gas flow, liter/minuteFluorescence detector maximum data rate, HzGlycan sample preparation time, hPumping speed, m³/h
Sialic Acid Profiling and Quantitation Kits | Analysis Current —1800127412.4×10⁻⁵
AdvanceBio Gly-X Technology | N-glycan Analysis 600...3,00050010741—

Full specifications

Core Performance & Functional Specifications
Pumping speed 0.4 mL/min
Fluorescence Detector Maximum Data Rate 74 Hz
Glycan Sample Preparation Time 1 hour
Ion source Dual AJS ESI
Run Time 10 min
Sample volume 20 µL
Sheath Gas Flow 12 L/min
Software 2.3
LC system mfr 1290 System
Autosampler mfr Agilent Infinity multisampler multisampler
Column mfr 120
Detection mfr FLD or MS MS
Kit order number mfr -407
Dimensions, Weight & Mechanical Design
Mass spectrometer mfr 6545 TOF
Electrical, Power & Drive Specifications
Fragmentor Voltage 120 V
Nozzle Voltage 1800 V
Mobile phase A mfr 100
Mobile phase B mfr acetonitrile acetonitrile
Operating Conditions, Environment & Protection
Gas Temperature 350 °C
Sheath Gas Temperature 400 °C
Sialic acid release mfr 2 °C
DMB labeling mfr 3 °C

Description

Construction and positioning in the series

Behavior in the analytical run

Control, software and operation

Integration & Operating Notes

Process Limits
Sialic acid release and DMB labeling are fixed 1-hour prep steps

The 96-well sample preparation is a 1-hour procedure split into a sialic acid release stage and a DMB labeling stage; the 10-minute LC run time is only the analytical part, so plate throughput planning must budget the full prep hour before the first injection and for each subsequent plate.

Application Note 5994-2352EN, AdvanceBio Sialic Acid Profiling and Quantitation

Selection & Integration Q&A

When should I choose this sialic acid workflow instead of the AdvanceBio amino-acid analysis or Gly-X siblings?

Pick this kit (GKK-407) when the analyte is sialic acid released from a glycoprotein and quantitated by DMB labeling with a 10-minute RP-UHPLC/FLD run. The AAA sibling targets amino acids, Gly-X targets N-glycan labeling (InstantPC/2-AB), and HIC/EC-C18 are separation chemistries, so none substitutes for sialic acid release and labeling.

What sample-prep and throughput limits does the 96-well workflow impose on my lab?

Preparation is a 1-hour, 96-well-plate procedure covering sialic acid release and DMB labeling, separate from the 10-minute analytical run. Plate throughput is therefore set by the prep hour plus the multisampler's plate capacity, and the workflow has been demonstrated on rituximab, etanercept, NISTmAb and cetuximab.

What is included in the base kit and what must be ordered or maintained separately?

The base item is the AdvanceBio Sialic Acid profiling and quantitation kit, order number GKK-407. The 120 column, mobile phase A and acetonitrile B, the 1290 LC with Infinity multisampler, the FLD or 6545 LC/Q-TOF, and software 2.3 are separate; no certificates or accessory cables are listed for this workflow, so consumable and column replacement must be planned independently.

Dimensional Drawings & Technical Documentation

Technical documentation