Agilent Technologies Bond Elut Carbon S & Carbon S/NH2
Agilent Technologies Bond Elut Carbon S & Carbon S/NH2 — Sample preparation with Pumping speed 0.024 m³/h.
Bond Elut Carbon S is a 150 mg SPE cartridge combining carbon and NH2 sorbents for post-extraction cleanup of PFAS from complex matrices. It is validated for 59 target compounds in soil and egg matrices, with average recovery of 99.2% and RSD of 8.5% across all compounds. The cartridge is used upstream of LC/MS/MS to remove matrix interferences while preserving PFAS analytes.
Agilent Technologies Bond Elut Series — Model Comparison & Selection
| Model | Pumping speed, m³/h | Sample volume, milliliter | Drying gas temperature, °C | Average recovery all compounds, % | Cartridge sorbent mass, mg | Centrifugation speed, rpm |
|---|---|---|---|---|---|---|
| Bond Elut Carbon S & Carbon S/NH2 Current | 0.024 | 0.005 | 230 | 99.2 | 150 | 1900 |
| Bond Elut HLB | SPE Sorbent | 1.8×10⁻⁵ | 0.002 | 40 | 73.4...118 | 500 | — |
| Bond Elut Lipid Extraction | 3...5 | — | 30 | — | — | — |
| Bond Elut LMS | Large Molecule Size | — | 0.005 | — | — | — | 2800 |
Full specifications
| Pumping speed | 0.400 mL/min |
| Average Recovery (all Compounds) | 99.2 % |
| Centrifugation Speed | 1900 rpm |
| Centrifugation Time | 10 minutes |
| Column temperature | 30 °C |
| Drying Gas Flow | 4 L/min |
| Extraction Solvent Volume | 10 mL |
| Nebulizer Gas Pressure | 15 psi |
| Rsd (all Compounds) | 8.5 % |
| Sample Amount | 2 g |
| Sample volume | 5 µL |
| Sheath Gas Flow | 12 L/min |
| Target Spiking Solution Concentration | 250 ng/mL |
| Number of target compounds mfr | 59 |
| Polarity mfr | Negative Negative |
| Calibration levels mfr | Six Six |
| Recovery range (high-level spikes) mfr | 70...130 |
| RSD (high-level spikes) mfr | 30 |
| Ionization polarity mfr | Negative Negative |
| PFOS maximum level in eggs mfr | 1.0 μg/kg |
| PFOA maximum level in eggs mfr | 0.30 μg/kg |
| PFNA maximum level in eggs mfr | 0.70 μg/kg |
| PFHxS maximum level in eggs mfr | 0.30 μg/kg |
| Sum of four PFAS maximum level in eggs mfr | 1.7 μg/kg |
| Limit of quantification for PFOS in eggs mfr | 0.30 μg/kg |
| Limit of quantification for PFOA in eggs mfr | 0.30 μg/kg |
| Limit of quantification for PFNA in eggs mfr | 0.30 μg/kg |
| Limit of quantification for PFHxS in eggs mfr | 0.30 μg/kg |
| PFPeA calibration range mfr | 0.15...2.0 μg/kg |
| PFBS calibration range mfr | 0.13...1.8 μg/kg |
| PFHxA calibration range mfr | 0.15...2.0 μg/kg |
| HFPO-DA calibration range mfr | 0.3...4.0 μg/kg |
| PFOA calibration range mfr | 0.15...2.0 μg/kg |
| PFOS calibration range mfr | 0.14...1.92 μg/kg |
| PFNA calibration range mfr | 0.15...2.0 μg/kg |
| PFOSA calibration range mfr | 0.3...4.0 μg/kg |
| PFHpS recovery mfr | 95.5 |
| PFOSA recovery mfr | 109.0 |
| PFDS recovery mfr | 107.4 |
| Recovery range mfr | 70...130 |
| RSD high-level spikes mfr | 30 |
| Target compounds mfr | 59 |
| Carbon S for PFAS cartridge, 250 mg, 6 mL mfr | 5610 |
| Polypropylene autosampler screw top vials, 2 mL, and caps mfr | 5191 |
| Centrifuge tubes and caps, 15 mL mfr | 5610 |
| InfinityLab PFC delay column, 4.6 × 30 mm mfr | 5062 |
| ZORBAX RRHD Eclipse Plus C18 column, 2.1 × 100 mm, 1.8 μm mfr | 959758 |
| Vac Elut SPS 24 manifold with collection rack for 10 × 75 mm test tubes mfr | 12234003 |
| Collection rack and funnel set for 12 or 15 mL conical tubes, for Vac Elut SPS 24 manifold mfr | 12234027 |
| diSAmPAP mfr | < MRL MRL |
| DONA mfr | < MRL MRL |
| EtFOSE mfr | < MRL MRL |
| FBSA mfr | < MRL MRL |
| FDSA mfr | < MRL MRL |
| FHxSA mfr | < MRL MRL |
| HFPO-DA mfr | < MRL MRL |
| MeFOSE mfr | < MRL MRL |
| N-EtFOSA mfr | < MRL MRL |
| N-EtFOSAA mfr | < MRL MRL |
| NFDHA mfr | < MRL MRL |
| N-MeFOSA mfr | < MRL MRL |
| N-MeFOSAA mfr | < MRL MRL |
| PFBA mfr | 4.5 ng/g |
| PFBS mfr | < MRL MRL |
| PFDA mfr | < MRL MRL |
| PFDoDA mfr | < MRL MRL |
| PFDoS mfr | < MRL MRL |
| PFDS mfr | < MRL MRL |
| ammonia concentration in methanol mfr | 1 |
| tumble time mfr | 1 hour |
| cartridge rinse volume mfr | 5 mL |
| acetic acid neutralization volume mfr | 50 μL |
| extract aliquot volume mfr | 790 μL |
| purified water volume mfr | 200 μL |
| Cartridge Sorbent Mass | 150 mg |
| Drying Gas Temperature | 230 °C |
| Sheath Gas Temperature | 250 °C |
| isotope performance standard volume mfr | 10 μL |
Description
Construction and series positioning
- Bond Elut Carbon S is a dual-layer SPE cartridge containing 150 mg of sorbent: a carbon layer for retention of matrix interferences and an NH2 layer for complementary cleanup. This configuration is distinct from the sibling Bond Elut Carbon (carbon + NH2 without the 'S' designation) and from C18, ENV, and Focus sorbents in the same series.
- The 'S' modification is intended for PFAS analysis, where the carbon sorbent removes interfering organic matter while the NH2 layer helps retain polar matrix components without irreversibly binding target PFAS.
Behavior under load and in different media
- The cartridge is used with a 10 mL extraction solvent volume and a 2 g sample amount in the validated method. Pumping speed is 0.400 mL/min, which controls residence time and analyte recovery.
- For soil matrices, the method covers loamy sand, reed sedge peat, and topsoil; for egg matrices, it is used after QuEChERS cleanup. Recovery across 59 PFAS averages 99.2% with RSD 8.5%; high-level spikes show a recovery range of 70–130% and RSD of 30%.
- Individual recoveries include PFHpS 95.5%, PFOSA 109.0%, and PFDS 107.4%. Calibration ranges for individual PFAS are in the low µg/kg range (e.g., PFOS 0.14–1.92 µg/kg, PFOA 0.15–2.0 µg/kg).
Installation, connection, and operation
- The cartridge is used in a standard SPE manifold or with a vacuum pump; no electrical connection is required. The method specifies centrifugation at 1900 rpm for 10 minutes after extraction, and drying gas at 4 L/min and 230 °C for the LC/MS/MS interface.
- LC/MS/MS parameters include column temperature 30 °C, sheath gas 12 L/min at 250 °C, nebulizer gas 15 psi, nozzle voltage 0 V, and negative ionization polarity. Sample injection volume is 5 µL.
- The application notes describe use with an Agilent 6475 triple quadrupole LC/MS system; the cartridge is compatible with standard LC/MS/MS workflows for PFAS.
Integration & Operating Notes
Deviating from the validated 0.400 mL/min flow changes analyte residence time on the carbon sorbent and can shift recoveries outside the 70–130% acceptance range. Use a calibrated syringe or peristaltic pump and verify flow before each batch.
The method is validated for 2 g sample amount; higher loads can overload the 150 mg sorbent bed, causing breakthrough of PFAS and matrix interference in the LC/MS/MS. For higher sample masses, split across multiple cartridges or use a larger sorbent mass.
After SPE, the eluate must be centrifuged at 1900 rpm for 10 minutes to remove residual particulates that would otherwise foul the LC column and nebulizer. Skipping this step risks clogging and carryover in the LC/MS/MS.
The validated method uses drying gas 4 L/min at 230 °C, sheath gas 12 L/min at 250 °C, nebulizer 15 psi, nozzle voltage 0 V, column 30 °C, and negative polarity. These settings are optimized for PFAS; re-optimize if using a different instrument or source geometry.
Selection & Integration Q&A
Choose Carbon S for PFAS in complex matrices (soil, eggs) where both carbon and NH2 cleanup are needed; the 'S' variant is validated for 59 PFAS with 99.2% average recovery. Standard Carbon lacks the S modification; C18 is for non-polar analytes and does not provide the same PFAS recovery.
The method uses an Agilent 6475 triple quadrupole LC/MS with negative polarity, drying gas 4 L/min at 230 °C, sheath gas 12 L/min at 250 °C, nebulizer 15 psi, nozzle voltage 0 V, column 30 °C, and 5 µL injection. A centrifuge capable of 1900 rpm for 10 minutes is needed post-SPE.
The cartridge is used on a standard SPE vacuum manifold; no electrical connection. Each cartridge is single-use; the validated method uses 2 g sample and 10 mL extraction solvent at 0.400 mL/min. Centrifugation at 1900 rpm for 10 minutes is required after elution. No duty-cycle limit is specified beyond single-use.
The base delivery is the cartridge only; the method requires LC/MS-grade solvents for the 10 mL extraction, a centrifuge for 1900 rpm/10 min, and an SPE manifold. No replacement parts are listed; the cartridge is single-use. LC column and MS source maintenance follow standard PFAS methods.