Agilent Technologies industrial gas analysis, composition and impurities

Agilent Technologies industrial gas analysis, composition and impurities — Gas chromatography.

The Agilent three-channel gas impurities GC analyzer is configured to UOP 1945 for trace H2, O2, N2 and extended hydrocarbons in industrial gas streams. Its 0.01 mol% typical quantitation limit distinguishes it from the CO-CO2 and polymer-characterization siblings in the same series. It serves as the composition and impurity measurement stage in gas quality monitoring systems.

Agilent Technologies Gas Impurities Measurements GC Analyzers Series — Model Comparison & Selection

Model Typical quantitation limit, mol%
industrial gas analysis, composition and impurities Current 0.01
CO-CO2 Analyzer, carbon monoxide analyzer 0.01

Full specifications

Core Performance & Functional Specifications
Typical Quantitation Limit 0.01 mol%
Analyzer channels mfr Three-channel channel
Configured per published method mfr 1945 UOP
Analysis capacity for H2 mfr Yes Yes
Analysis capacity for O2 and N2 mfr Yes Yes
Extended hydrocarbon analysis mfr Yes Yes

Description

Construction and series positioning

Analytical behavior

Installation and operation

Integration & Operating Notes

Process Limits
Quantitation limit sets the minimum measurable impurity level

Species below the 0.01 mol% typical quantitation limit cannot be reliably reported; sample conditioning and calibration must keep target impurities above this threshold or results fall outside the validated range.

Factory Specification Sheet
Process Limits
Method configuration fixed to UOP 1945 governs sample handling

Because the analyzer is configured per UOP 1945, sample pressure, purge and valve timing must follow that method; deviating from its sampling conditions invalidates the channel assignments for H2, O2/N2 and hydrocarbons.

Factory Specification Sheet
Control & I/O
Three channels require coordinated data acquisition

The H2, O2/N2 and hydrocarbon channels produce separate signals that the data system must acquire and align in time; integration planning should confirm the controller can handle three simultaneous detector outputs.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose this gas impurities analyzer instead of the CO-CO2 or polymer-characterization siblings?

Pick this model when the stream needs simultaneous trace H2, O2, N2 and extended hydrocarbon measurement per UOP 1945 at a 0.01 mol% quantitation limit. Choose the CO-CO2 sibling for carbon monoxide-focused analysis and the polymer sibling for polymer characterization; the channel count and target species differ.

What must the sample-handling and data system upstream and downstream of this analyzer provide?

Sampling must deliver gas at conditions consistent with the UOP 1945 configuration, and the data system must acquire three parallel channel signals (H2, O2/N2, hydrocarbons) with time alignment. No drive, controller or fitting part numbers are given in the supplied facts, so confirm them against the instrument manual.

What mounting and duty-cycle limits apply to this analyzer?

The supplied facts contain no mounting, environmental or duty-cycle data for this model; the attached brochure digest covers the wider 8890 portfolio without model-specific limits. Obtain installation environment and duty-cycle requirements from the instrument manual before siting.

What maintenance schedule and accessories come with the base delivery?

No maintenance intervals, consumables or accessory list are stated in the supplied facts. Columns, calibration gases and spare parts should be planned separately; consult the instrument manual for service intervals and the order documentation for what the base delivery includes.