Agilent Technologies CO-CO2 Analyzer, carbon monoxide analyzer
Agilent Technologies CO-CO2 Analyzer, carbon monoxide analyzer — Gas chromatography.
The Agilent CO/CO2 Analyzer is a three-channel gas chromatography configuration built on the 8890 GC platform and configured to UOP 1945 for carbon monoxide and carbon dioxide measurement in gas streams. It is one member of the energy and chemical analyzer portfolio, distinguished by its dedicated CO/CO2 channel set rather than the refinery, natural gas or fuel analyzer option groups. It serves as the impurity-measurement stage in industrial gas quality systems, with a typical quantitation limit of 0.01 mol%.
Agilent Technologies Gas Impurities Measurements GC Analyzers Series — Model Comparison & Selection
| Model | Typical quantitation limit, mol% |
|---|---|
| CO-CO2 Analyzer, carbon monoxide analyzer Current | 0.01 |
| industrial gas analysis, composition and impurities | 0.01 |
Full specifications
| Typical Quantitation Limit | 0.01 mol% |
| Analyzer channels mfr | Three-channel channel |
| Configured per published method mfr | 1945 UOP |
| Analysis capacity for H2 mfr | Yes Yes |
| Analysis capacity for O2 and N2 mfr | Yes Yes |
| Extended hydrocarbon analysis mfr | Yes Yes |
Description
Construction and positioning in the series
- Three-channel GC analyzer configuration; the CO/CO2 modification is configured per the published UOP 1945 method.
- Sits inside the Agilent 8890 energy and chemical analyzer portfolio alongside refinery gas (#600–#605), natural gas (#610–#615), fuel (#620–#632), process gas (#640/#641), transformer oil gas (#650) and greenhouse gas (#661) analyzer options. The CO/CO2 card is the dedicated carbon-oxide channel set, not a multi-application refinery or fuel analyzer.
- The same platform also carries analysis capacity for H2 and for O2/N2, and extended hydrocarbon analysis, so the CO/CO2 configuration is a channel selection within a shared GC architecture rather than a separate instrument family.
Analytical behavior
- Typical quantitation limit is 0.01 mol% for the CO/CO2 measurement; this is the only performance figure verified for this model.
- No digitized response curves, carrier-gas data or temperature-program data were supplied, so linearity, drift and run-time behavior cannot be stated here.
Installation, control and operation
- The attached brochure digest contains no actionable engineering facts (no sections, no connection or control details), so electrical ratings, interface protocols, utility requirements and mounting instructions for this model are not documented in the supplied material and must be taken from the instrument manual before integration.
Selection & Integration Q&A
Pick this configuration when the measurement task is carbon monoxide and carbon dioxide per UOP 1945 at a 0.01 mol% quantitation limit. Choose the refinery gas (#600–#605) or natural gas (#610–#615) options when the scope is full hydrocarbon speciation; those are separate channel sets, not upgrades of this one.
Sample conditioning must deliver gas at the pressure, temperature and cleanliness required by UOP 1945, since the analyzer is configured to that method. Electrical supply, communications and controller interfaces are not documented in the supplied brochure, so they must be confirmed from the instrument manual before wiring.
The supplied documents contain no mounting, ambient-temperature, vibration or duty-cycle data for this model. Because it is a three-channel 8890-platform GC, siting and duty limits must be taken from the platform site-planning guide; do not assume benchtop or shelter installation from this card.
No consumables, spare columns, carrier-gas hardware or cables are listed in the supplied facts, and the brochure digest has no sections. Columns, valves and gas consumables are platform items whose part numbers and replacement intervals must be obtained from the 8890 GC manual and the order configuration.