Agilent Technologies Cary 60 Fiber Optic UV Dissolution System
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Cary 60 Fiber Optic UV Dissolution System

Agilent Technologies Cary 60 Fiber Optic UV Dissolution System — Dissolution testing.

The Cary 60 Fiber Optic UV Dissolution System is an online dissolution testing configuration that uses in situ fiber optic probes and a multiplexer with the Cary 60 UV-Vis spectrophotometer. It supports 1 to 2 dissolution apparatus and covers a 190 nm wavelength range with 1.5 nm slit width. It is distinguished from the Multicell sibling by probe-based, pump-free sampling for real-time in situ measurement.

Agilent Technologies Cary Series — Model Comparison & Selection

Model Wavelength rangeBaseline flatnessPhotometric accuracySlit width, nm
Cary 60 Fiber Optic UV Dissolution System Current 19010.0051.5
Cary 60 Multicell UV Dissolution System 19010.0051.5

Full specifications

Core Performance & Functional Specifications
Wavelength range 190 nm
Baseline Flatness 0.001 Abs
Photometric accuracy 0.005 Abs
Software package mfr Cary WinUV WinUV
Number of apparatus mfr 1...2
Lamp type mfr Xenon flash flash
Instrument design mfr Scanning Scanning
Wavelength accuracy mfr 0.5 nm
Wavelength reproducibility mfr 0.1 nm
Stray light mfr 1.0
Path lengths mfr 0.2 mm
Closed loop sampling mfr Yes Yes
Path lengths (mm) mfr 0.2
Automated dosage delivery mfr Yes Yes
Sampling mfr Simultaneous Simultaneous
Sample filtration (min. pore size μm) mfr 0.2 μm
Sample archival mfr Yes Yes
minimum reading interval mfr 45 seconds
lamp lifetime mfr 10 years
photometric linear range mfr 3.5 Abs
Dimensions, Weight & Mechanical Design
Slit Width 1.5 nm
path length (multicell) mfr 0.2...10 mm
path length (fiber optic tips) mfr 1...20 mm
Operating Conditions, Environment & Protection
Photometric noise mfr 0.0001 Abs

Description

Construction and series positioning

Optical performance

Operation and integration

Integration & Operating Notes

Control & I/O
Cary WinUV software is the control platform

The system is operated through the Cary WinUV software package. No additional controller, cable, or interface specifications are provided in the available document digest; verify PC and interface requirements against the full manual.

Brochure Online UV-Vis Dissolution Systems Cary 60 5991-4048EN Agilent

Selection & Integration Q&A

When should I choose the Cary 60 Fiber Optic system instead of the Multicell sibling?

Choose Fiber Optic when you need in situ measurement with fiber optic probes and a multiplexer, avoiding pump-based sampling. Choose Multicell when your workflow requires a multicell changer with peristaltic pump or 850-DS Sampling Station. Both support 1 to 2 apparatus and share Cary WinUV software.

What adjacent components are required to operate this configuration?

The Fiber Optic configuration requires the Cary 60 UV-Vis spectrophotometer, a fiber optic multiplexer, and in situ fiber optic probes, all controlled by Cary WinUV software. No pump is used in this configuration. Confirm probe compatibility and multiplexer channel count against your apparatus count (1 to 2).

What are the mounting and environment limits for the Fiber Optic system?

The available document digest does not specify mounting, environmental, or duty-cycle limits for this configuration. Consult the full Cary 60 UV-Vis and dissolution system manuals for installation clearances, temperature/humidity ranges, and duty-cycle guidance before site planning.

What maintenance and accessories are needed beyond the base delivery?

The digest does not list maintenance intervals or included accessories. Fiber optic probes and multiplexer are configuration-defining and should be confirmed in the order. Replacement probes, cables, and the Cary WinUV software license should be verified against the quotation; no service schedule is provided in the available facts.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Agilent Online UV-Vis Dissolution
Brochure ·5,3 МБ ·12 pp.
View PDF