Agilent Technologies GC/MS Instruments, GC/MS Systems, GC/MS Analysis
Agilent Technologies GC/MS Instruments, GC/MS Systems, GC/MS Analysis — Gas chromatography mass spectrometry gc ms.
The Agilent 7010D is a triple quadrupole GC/MS system with heated gold quadrupoles and a JetClean ion source, covering a mass range to 1050 m/z at attogram-level detection limits. It is the highest-sensitivity modification in the GC/TQ line, positioned above the single-quadrupole 5977C MSD family. It serves targeted trace analysis in complex matrices where peak-area RSD of 5% and S/N 100 are required.
Agilent Technologies GC/MS Series — Model Comparison & Selection
| Model | Mass range | Detection limit | Sensitivity | Carrier gas | Ion source | Peak area rsd, % |
|---|---|---|---|---|---|---|
| GC/MS Instruments, GC/MS Systems, GC/MS Analysis Current | 1050 | attogram-level | — | — | 2.0 | 5 |
| GC/MS Ion Sources, GC Inlets | 1050 | — | 100 | 2 | — | — |
Full specifications
| Detection limit | attogram-level |
| Ion source | 2.0 |
| Peak Area Rsd | 5 % |
| Sensitivity (S/N) mfr | 100 |
| Quadrupole mfr | heated gold quadrupoles quadrupoles |
| Ion source cleaning mfr | JetClean JetClean |
| Acquisition software mfr | 13.0 |
| Instrument uptime mfr | 100 injections |
| Average instrument repair experience mfr | 10 years |
| Parts available right away mfr | 96 |
| Parts accessible at worldwide logistics centers mfr | Millions Millions |
| Repairs fixed during first visit mfr | 85 |
| Service engineers worldwide mfr | 1850 |
| Priority service call response time mfr | 1...2 days |
| Mass range | 1050 m/z |
| Mass spectrometer type mfr | triple quadrupole quadrupole |
Description
Construction and series positioning
- Triple quadrupole mass spectrometer with heated gold quadrupoles; the 7010D is the current GC/TQ generation, following the 7010A/7010B/7010C.
- Distinct from the 5977C GC/MSD family (single quadrupole, including EI, Inert Plus, EI/CI and HES variants) and from GC/MS ion sources and inlets, which are separate sibling entries.
- Mass range extends to 1050 m/z; detection limit is stated at attogram level.
Analytical behavior
- Peak-area RSD is 5%, with sensitivity specified as S/N 100.
- The JetClean ion source cleaning function is integrated; the ion source specification carries a value of 2.0 in the matched spec table without a stated unit, so it is not interpreted here.
- No digitized response curves were supplied; behavior under load is characterized only by the stated RSD and S/N figures.
Control and software
- Acquisition software is listed as version 13.0.
- The MassHunter software suite covers instrument control (LC/MS and GC/MS), targeted screening workflows (ChemVista, PCDL, MRM databases), nontargeted analysis, BioConfirm and Networked Workstation configurations.
- Companion GC systems referenced in the 7010D document are the 8890B and 8850; no ordering codes or size variants are printed in the supplied digests.
Integration & Operating Notes
Instrument control is provided through MassHunter Acquisition Software, listed at version 13.0. Workflows for targeted screening (ChemVista, PCDL, MRM databases) and nontargeted analysis run on the same suite, so the data-system specification should be fixed before the instrument is ordered.
Peak-area RSD is specified at 5%. Methods transferred from other GC/MS platforms should be re-validated against this figure, since precision depends on the ion source condition and the JetClean cleaning state at the time of acquisition.
The ion source is equipped with JetClean cleaning. Sensitivity is stated as S/N 100 and detection limit at attogram level; these figures depend on source cleanliness, so the JetClean routine should be scheduled as part of the preventive maintenance plan rather than run only after signal loss.
Selection & Integration Q&A
Choose the 7010D when targeted trace analysis needs MS/MS selectivity and the stated 5% peak-area RSD at attogram-level detection limits. The 5977C family (EI, Inert Plus with HydroInert source, EI/CI, HES) is a single-quadrupole MSD line and is the appropriate neighbor when full-scan spectra and ion-source variants matter more than triple-quadrupole MRM sensitivity.
The 7010D document references the 8890B and 8850 GC systems as companions, and instrument control runs through MassHunter Acquisition Software version 13.0. Targeted screening uses ChemVista, PCDL and MRM databases within the MassHunter suite, so the GC model and data-system configuration should be fixed together with the mass spectrometer.
The supplied digests contain no environmental or duty-cycle tables for the 7010D. The only operational figures given are the 5% peak-area RSD, S/N 100 and attogram-level detection limit; installation environment and duty cycle must be taken from the full 7010D manual, which is not included in the supplied extracts.
The ion source uses JetClean cleaning, which should be scheduled to maintain the stated S/N 100 and attogram-level detection limit. The service program quotes 1–2 day priority response, 96% immediate parts availability and 85% first-visit repair; cables, consumables and service contracts are not listed in the supplied facts and must be confirmed at order.