Agilent Technologies PCG 752

Agilent Technologies PCG 752 — Vacuum technologies.

The PCG 752 is a combination Pirani/capacitance diaphragm gauge with a nickel-plated filament, covering 5×10⁻⁵ to 1500 mbar via two constantly active sensors. It is the nickel-filament variant of the PCG-750 series, sharing the NW 16KF flange and logarithmic 0.61–10.23 V output. It serves as a single wide-range vacuum sensor for rough-to-fine processes, with relay setpoints and optional Profibus.

Agilent Technologies Active Gauges Series — Model Comparison & Selection

Model Measurement rangeOperating temperature, °CStorage temperature, °CInternal volume, microliterOperationResponse time, ms
PCG 752 Current 510204.71030
FRG-700/702 1.82...8.6540202910

Full specifications

Core Performance & Functional Specifications
Measurement range 5 mbar
Data Rate 12 Mbaud
Diffusion Pump Pumping Speed 50 L/s
Internal Volume 4.7 microliter
Operation 10 °C
Response Time 30 ms
Switching Time 30 ms
Vacuum connection 1.4435 millimeter
Vacuum gauge measurement range mfr 6 pressure
Dry scroll pump typical size mfr 3...30 h
Turbomolecular pump pumping speed mfr 70...3 L/s
Measurement principle mfr thermal conductance acc. to Pirani Pirani
Accuracy (N2) mfr 2.5 reading
Repeatability (N2) mfr 1 reading
Output impedance mfr 2 proof
Load impedance mfr 10
Gauge identification mfr 71.5
HV adjustment mfr 10 mbar
ATM adjustment mfr 100 mbar
Switching functions setting range mfr 5.0 mbar
Hysteresis mfr 10 threshold
Switching characteristics mfr Low Trip Point Point
Switching function type mfr 1 function
Contact rating closed mfr 30 resistive
Contact rating open mfr LED lit solid solid
Ripple mfr 1 Vpp
Sensor cable mfr 0.14 conductor
Grounding concept vacuum connection to signal common mfr 10 nF
RS232C data format mfr 8 handshake
Materials exposed to vacuum - feedthrough mfr glass glass
Materials exposed to vacuum - orifice mfr stainless steel steel
Materials exposed to vacuum - diaphragm mfr ceramic ceramic
Materials exposed to vacuum - further materials mfr 1.4301 SnAg
Permissible pressure (absolute) mfr 5 bar
Bursting pressure (absolute) mfr 10 bar
Use mfr 2000 NN
Grounding concept mfr 10 nF
Materials exposed to vacuum - Feedthrough mfr glass glass
Materials exposed to vacuum - Orifice mfr stainless steel steel
Materials exposed to vacuum - Diaphragm mfr ceramic ceramic
Materials exposed to vacuum - Further materials mfr 1.4301 SnAg
AGPS45INT mfr Power supply, PVG-PCG, international plug. plug.
PCG750KF16 mfr -750 KF.
PCG750KF16RS mfr -750 KF.
PCG750KF16SD1 mfr -750 mbar.
PCG750KF16SD2 mfr -750 Torr.
PCG750KF16SD3 mfr -750 Pascal.
PCG750KF16SP mfr -750 mbar.
PCG752KF16 mfr -752 KF.
PCG752KF16SD1 mfr -752 mbar.
PCG752KF16SD2 mfr -752 Torr.
PCG752KF16SD3 mfr -752 Pascal.
PCG752KF16SP mfr -752 mbar.
Default setting mfr 0.1 Chex
PCG-752 mfr Ni Ni
Feedthrough mfr glass glass
Orifice mfr stainless steel steel
Diaphragm mfr ceramic ceramic
Further materials mfr 1.4301 SnAg
Year's mean mfr 65
During 60 days mfr 85
Grounding concept Vacuum connection to signal common mfr 10 nF
Data format mfr 8 handshake
About this manual mfr 6
Validity mfr 6
Definitions and terminology mfr 7
Definition of Caution, Warning and Note mfr 7
Warning Symbols mfr 8
Safety mfr 9
Proper use mfr 9
Improper use mfr 10
Safety guideline for PCG-750, PCG-752 mfr 11
Disposal mfr 12
Service mfr 13
Dimensions, Weight & Mechanical Design
Cable length 100 m
RS232C operation cable length mfr 30 m
RS232C transmission rate mfr 57600 baud
Mounting orientation mfr any any
Cable length, system wiring mfr according to Profibus specifications specificati
Cable length FCC 68 mfr 30 m
Transmission rate mfr 57600 baud
RS232C cable length mfr 30 m
Electrical, Power & Drive Specifications
Voltage vs. pressure mfr 1.286 logarithmic
Supply voltage at the gauge mfr 15 VDC
Fuse to be connected mfr 1 AT
Fuse to be connected 3) mfr 1 AT
Interfaces, Connections & Control
Profibus Data Rate 12 Mbaud
Turbomolecular pump controller protection class mfr 54
Output signal measurement range mfr 0.61 V
Diagnostic port mfr 2.5 pin
Power consumption without fieldbus mfr 2.5 W
Power consumption with fieldbus mfr 3 W
Profibus interface physical mfr 485
Profibus node address default setting mfr 0.1 Chex
Profibus connection cable mfr 9 cable
Profibus cable length, system wiring mfr according to Profibus specifications specificati
Weight w/o fieldbus interface mfr 115 g
Weight with fieldbus interface mfr 230 g
Profibus connection mfr 9
w/o fieldbus interface mfr 115 g
with fieldbus interface mfr 230 g
Specification, data format, communication protocol mfr 485
Weight without fieldbus interface mfr 115 g
Materials, Media & Process Compatibility
Materials exposed to vacuum - filament PCG-752 mfr Ni Ni
Materials exposed to vacuum - Filament PCG-752 mfr Ni Ni
Filament mfr 160 °C
Operating Conditions, Environment & Protection
Operating temperature 10 °C
Protection rating 40
Storage temperature 20 °C
Relative humidity year's mean mfr 65
Relative humidity during 60 days mfr 85
Relative humidity - Year's mean mfr 65
Relative humidity - During 60 days mfr 85

Description

Construction and series positioning

Behavior across the measuring range

Installation, control and operation

Integration & Operating Notes

Electrical
Supply must be SELV and fused at 1 AT

The gauge is designed for a grounded protective extra-low voltage supply; connecting to a non-SELV or unfused source risks damage and violates the manual's electrical safety requirements. Agilent controllers meet this, but third-party supplies must be checked for 15–30 VDC output, ≤1 Vpp ripple, and a 1 AT fuse in the feed line.

User Manual, Electrical Connection / Technical Specifications p.18
Process Limits
Do not exceed 5 bar absolute process pressure

Permissible absolute pressure is ≤5 bar and bursting pressure is 10 bar. Exceeding 5 bar risks sensor damage and unsafe operation; use overpressure-rated clamps and O-rings with outer centering ring for the KF connection, and never use the gauge with flammable or combustible gas mixtures in the explosion range.

User Manual, Technical Specifications p.19 / Product Description
Control & I/O
Configure setpoints before relying on relay outputs

SP1 and SP2 are factory set to the lower measurement range limit and therefore do not switch by default. Any interlock or valve control wired to the relay contacts will remain inactive until the thresholds are set via the diagnostic port or display. Also avoid pressing the <SP> button during process control, as it suppresses the measurement signal and outputs the threshold value instead.

User Manual, Switching Functions p.33 / Adjusting the Setpoints p.36
Mounting
Mount vibration-free; vacuum connection ≤80 °C

Any orientation is permitted, but the gauge must not be subjected to vibration, so avoid direct mounting on roughing pumps or vibrating lines. The vacuum connection temperature must stay ≤80 °C; if bakeout or hot process lines are involved, provide thermal isolation or remote mounting to keep the flange within this limit.

User Manual, Vacuum Connection p.24 / Technical Specifications p.19
Control & I/O
Profibus and RS232C must not be used simultaneously

On Profibus variants, the RS232C diagnostic port must not be operated while the Profibus interface is active. The GSD file must be installed on the bus master before commissioning, and the node address (0–125 dec, default 5Chex) is set via hexadecimal switches and polled only at power-on, so address changes require a power cycle.

User Manual, Profibus Operation p.40
Maintenance
Perform ATM and HV adjustments after contamination or drift

The gauge is factory calibrated, but zero drift can occur with long operation or contamination. ATM adjustment should be done at atmospheric pressure after at least 10 minutes; HV adjustment after evacuating to p << 10⁻⁵ mbar and waiting at least 2 minutes. For severe contamination or malfunction, the sensor is replaceable (PCG752KF16RS); always quote the nameplate data when ordering spares.

User Manual, Maintenance and Adjusting the Gauge p.43–44 / Spare Parts
Cooling & Media
Gas correction factors apply only below 1 mbar

In the Pirani range below 1 mbar, readings for gases other than air must be multiplied by calibration factors (e.g., Ar 1.7, CO₂ 0.9, H₂ 0.5). Above ~10 mbar the capacitive sensor is gas-independent, so no correction is needed there. This matters when the gauge is used for process gases rather than air/N₂.

User Manual, Gas Type Dependence p.22

Selection & Integration Q&A

When should I choose the PCG 752 rather than the PCG-750 or a full-range FRG gauge?

Choose the PCG 752 when a nickel-plated filament is preferred over the PCG-750's tungsten filament; performance and range are identical. For UHV below 5×10⁻⁵ mbar, use an FRG-700/702 or FRG-705/707 Bayard-Alpert Pirani gauge instead, as the PCG series stops at 5×10⁻⁵ mbar.

What supply and cabling does the PCG 752 require for reliable operation?

A SELV supply of +15…+30 VDC with ≤1 Vpp ripple, fused at 1 AT. Use shielded sensor cable with 0.14 mm² conductors, max 100 m; the RS232C cable is limited to 30 m. Connect the shield to chassis ground on one side to avoid ground loops, and keep potential difference between supply common and housing ≤18 V.

Can the PCG 752 be mounted on a vibrating roughing line or used outdoors?

No. The gauge must be mounted so that no vibrations occur, so avoid direct mounting on pumps or vibrating lines; use vibration isolation. It is rated IP 40 for indoor use only, altitude ≤2000 m, humidity ≤65% annual mean (≤85% for 60 days) without condensation, and ambient +10…+50 °C.

What maintenance and accessories are needed beyond the base gauge?

The base delivery does not include a power supply (AGPS45INT is an accessory), nor cables or a display. Plan for periodic ATM/HV adjustment via the <ADJ> button and replacement of the sensor (PCG752KF16RS) if contaminated. The RS232C diagnostic port requires a 2.5 mm 3-pin cable; Profibus variants need the GSD file and a 9-pin D-Sub cable.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
PCG-750 / PCG-752 Vacuum Gauge Controller User Manual
Manual ·51 pp.
View PDF