Agilent Technologies Rapid fire mass spectrometry, high throughput screening
Agilent Technologies Rapid fire mass spectrometry, high throughput screening — Liquid chromatography mass spectrometry lc ms.
The RapidFire 400 is a high-throughput screening front end that couples solid-phase extraction to mass spectrometry, using a 4 µL C18 SPE cartridge (100 Å pore size) reusable for thousands of injections. It stores up to 138,240 samples and compresses data acquisition from minutes to seconds, positioning it as the high-capacity alternative to the multiplexing StreamSelect sibling.
Agilent Technologies High Throughput LC MS Series — Model Comparison & Selection
| Model | Sample volume, milliliter | Autosampler temperature, °C | Capillary voltage, V | Column temperature, °C | Drying gas temperature, °C | Fragmentor voltage, V |
|---|---|---|---|---|---|---|
| Rapid fire mass spectrometry, high throughput screening Current | — | — | — | — | — | — |
| Multiplexing LC/MS, multichannel, multiple stream StreamSelect | 0.003 | 4 | 500 | Ambient | 250 | 200 |
Full specifications
| Spe Cartridge C18 Volume | 4 µL |
| Sample storage capacity mfr | 138240 samples |
| Data acquisition time mfr | utes to seconds seconds |
| SPE cartridge reusability mfr | thousands of injections injections |
| C18 pore size mfr | 100 |
Description
Construction and series positioning
- The RapidFire 400 is a standalone high-throughput SPE-MS system built around a 4 µL C18 cartridge with 100 Å pores; the cartridge is a consumable rated for thousands of injections before replacement.
- Within the series it is the high-capacity, single-stream configuration: the sibling StreamSelect model is a multiplexing LC/MS front end with multiple streams and a 0.4-minute pumping speed, whereas the RapidFire 400 emphasizes sample storage (138,240 samples) and rapid batch processing.
- The brochure describes an integrated plate handler robot, barcode reader, and temperature-controlled sample storage as part of the system architecture.
Behavior and throughput
- Data acquisition time is stated as "minutes to seconds," indicating that per-sample SPE-MS readout is compressed relative to conventional LC/MS workflows.
- The 4 µL C18 cartridge volume and 100 Å pore size define the extraction bed; cartridge reusability of thousands of injections sets the practical maintenance interval.
- No digitized curve points or performance curves are supplied, so no gradient, pressure, or flow behavior can be asserted.
Installation, control and operation
- The attached brochure digest contains no sections or actionable engineering facts on utilities, connections, or control interfaces; installation specifics must come from the full manual.
- The integrated plate handler and barcode reader imply robotic plate loading and sample tracking as part of normal operation, but no further control details are verified.
Selection & Integration Q&A
Choose the RapidFire 400 for high-capacity single-stream screening with up to 138,240 stored samples and SPE-MS readout in seconds. Choose the StreamSelect sibling when multiple parallel streams and 0.4-minute pumping cycles are required for multiplexed LC/MS.
Plan for the SPE cartridge type matched to the application (4 µL C18 with 100 Å pores is one option; types A–H6, C12 µL, O, and custom also exist) and for barcode-labeled plates compatible with the integrated plate handler. The brochure digest does not list included accessories, so confirm the base delivery scope.
The system includes temperature-controlled sample storage and an integrated plate handler; the brochure digest provides no ambient temperature, humidity, or duty-cycle ratings. Verify these limits in the full manual before committing to round-the-clock screening campaigns.
The SPE cartridge is reusable for thousands of injections and then must be replaced; stock spare cartridges of the selected type. The brochure digest gives no other service intervals, so maintenance scheduling beyond cartridge replacement must be taken from the full manual.