Agilent Technologies Multiplexing LC/MS, multichannel, multiple stream StreamSelect
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Multiplexing LC/MS, multichannel, multiple stream StreamSelect

Agilent Technologies Multiplexing LC/MS, multichannel, multiple stream StreamSelect — Liquid chromatography mass spectrometry lc ms.

The Agilent StreamSelect multiplexing LC/MS system is a multichannel, multiple-stream front end that time-slices a single triple quadrupole MS across four parallel UHPLC streams. It is defined by the StreamSelect Console software and the attached application methods, not by a single hardware rating. Its purpose is to raise sample throughput by overlapping chromatographic runs from several streams into one MS acquisition cycle.

Agilent Technologies High Throughput LC MS Series — Model Comparison & Selection

Model Sample volume, milliliterAutosampler temperature, °CCapillary voltage, VColumn temperature, °CDrying gas temperature, °CFragmentor voltage, V
Multiplexing LC/MS, multichannel, multiple stream StreamSelect Current 0.0034500Ambient250200
Rapid fire mass spectrometry, high throughput screening ——————

Full specifications

Core Performance & Functional Specifications
Column temperature Ambient
Gas Flow 14 L/min
Sample volume 3 μL
Sheath Gas Flow 12 liter/minute
Analytical column mfr 120 μm
Stop time mfr 5 minutes
Isocratic separation mfr 5 minutes
Instrument mfr 6490 LC/MS
Ion mode mfr Positive Positive
Nebulizer mfr 20 psi
Intra-assay imprecision ADMA mfr 1.7
Intra-assay imprecision SDMA mfr 2.4
Inter-assay imprecision ADMA mfr 3.0
Inter-assay imprecision SDMA mfr 2.8
Mean bias at 30 ng/mL ADMA mfr 0.7
Mean bias at 30 ng/mL SDMA mfr 2.5
Mean bias at 90 ng/mL ADMA mfr 1.2
Mean bias at 90 ng/mL SDMA mfr 3.9
Needle wash mfr 50 % Methanol
Nebulizer pressure mfr 45 psi
Q1/Q3 resolution mfr 0.7 unit
Dwell time mfr 18 ms
Calibrator range mfr 5...5,000 ng/mL
Chromatographic method duration mfr six-minute minute
Calibration linearity (R2) mfr 0.996
Retention time reproducibility (%RSD) mfr 0.43...1.54
Quantitation accuracy mfr 95.3...109.1
Electrical, Power & Drive Specifications
Capillary Voltage 500 V
Fragmentor Voltage 200 V
Mobile phase A mfr 5
Mobile phase B mfr 0.01 acid
EMV mfr 100 V
Operating Conditions, Environment & Protection
Autosampler Temperature 4 °C
Drying Gas Temperature 250 °C
Sheath Gas Temperature 300 °C

Description

Architecture and series positioning

Behavior under load and in different methods

Control, installation and operation

Integration & Operating Notes

Control & I/O
Stream scheduling is driven by the StreamSelect Console method

Acquisition across streams is coordinated by the MassHunter StreamSelect Console, so the batch and acquisition method must be built and submitted there; the LC and MS methods alone do not define the stream timing. Plan method development around the Console workflow described in the Quick Start Guide.

G4931 90001 StreamSelect QuickStart 8.0
Process Limits
Method timing must fit the multiplexed stream cycle

The ADMA/SDMA application uses a six-minute chromatographic method with a 5-minute stop time and 5-minute isocratic separation; stream overlap only works when each stream's run length is matched to the acquisition schedule. Methods that overrun the allotted window will collide with the next stream's injection.

Application note biomarker SDMA ADMA StreamSelect 5991-6764EN
Process Limits
Source settings are method-specific, not fixed hardware limits

Drying gas 250 °C, sheath gas 300 °C at 12 L/min, capillary 500 V, fragmentor 200 V and nebulizer 20–45 psi appear in the ADMA/SDMA method; the cannabinoid note uses a different MS platform (6470). Treat these as starting method values to be tuned per assay, not as instrument ratings.

Application note biomarker SDMA ADMA StreamSelect 5991-6764EN

Selection & Integration Q&A

When should I choose the StreamSelect multiplexing configuration instead of the Rapid Fire high-throughput screening sibling?

Choose StreamSelect when you need chromatographic separation on multiple parallel LC streams feeding one triple quadrupole, as in the four-stream ADMA/SDMA and cannabinoid methods. Rapid Fire is a different high-throughput screening approach without stream-multiplexed LC separation; pick it only when chromatographic resolution is not the bottleneck.

What adjacent system parts must be compatible with a StreamSelect setup?

The application notes pair StreamSelect with Agilent 1290 Infinity II UHPLC streams and either a 6490 or 6470 triple quadrupole MS, coordinated through the MassHunter StreamSelect Console. Confirm your LC pumps, autosampler and MS model are supported by the Console version in use before committing the configuration.

What maintenance and consumables are needed beyond the base delivery?

The method requires a 50% methanol needle wash and 4 °C autosampler operation, so wash solvent and autosampler cooling are routine consumables/checks. Analytical column is 120 µm with mobile phases 5 (A) and 0.01 acid (B). The Quick Start Guide covers Console software setup; hardware service intervals are not defined in the attached documents and must come from the LC/MS platform manuals.