Agilent Technologies Trace sulfur analysis
Agilent Technologies Trace sulfur analysis — Gas chromatography with Motor power 2.35 kW.
The Agilent Trace Sulfur Analysis is a configured 8890-series GC analyzer dedicated to trace sulfur measurement, built on the 8890A/B platform with a 54 × 54 × 50 cm, 50 kg bench footprint. It is distinguished within the Environmental GC Analyzer series by its sulfur-specific configuration rather than by hardware ratings. It serves as the analytical stage in process and environmental gas streams where sulfur species must be quantified at trace levels.
Agilent Technologies Environmental GC Analyzers Series — Model Comparison & Selection
| Model | Motor power, kW | Depth, mm | Frequency, Hz | Height, cm | Maximum altitude, m | Power outlet current, Amp |
|---|---|---|---|---|---|---|
| Trace sulfur analysis Current | 2.35 | 540 | 0.5 | 50 | 4615 | 20 |
| Analyzers to measure and monitor GHG emissions | 2.35 | 540 | 0.5 | 50 | 4615 | 20 |
Full specifications
| Motor power | 2350 W |
| Depth | 54 cm |
| Height | 50 cm |
| Weight | 50 kg |
| Width | 54 cm |
| Frequency | 50 % Hz |
| Power Outlet Current | 20 Amp |
| Line voltage mfr | 120 VAC |
| Current rating mfr | 19.6 amps |
| Maximum Altitude | 4615 m |
| Operating humidity range mfr | 5...95 |
| Storage humidity range mfr | 5...95 |
Description
Construction and positioning
- The analyzer is a configured Agilent 8890A/B gas chromatograph (site preparation document D0007040, Rev. 3.0) dedicated to trace sulfur analysis; the sibling model in the series addresses GHG emission measurement and monitoring, so the two are application-specific configurations of the same GC platform rather than different hardware classes.
- Bench footprint is 54 cm wide × 54 cm deep × 50 cm high at 50 kg; the 2350 W motor power figure is the only power-related value carried in the matched specs and is not a sulfur-specific rating.
Electrical and environmental envelope
- Line voltage is stated as 220 VAC with a 13.4 A current rating; the site preparation document covers 120 VAC Americas and 220/230/240 VAC configurations, so the supply must be confirmed against the delivered configuration before installation.
- Operating environment: 15–35 °C and 5–95 % humidity; storage: 40–70 °C and 5–95 % humidity. Maximum operating altitude is 4615 m.
- A 20 A power outlet current is specified, consistent with the 13.4 A draw at 220 VAC.
Operation and control
- No curve points, certificates, applications or detailed manual sections were supplied for this configuration; behavior under load and mode-specific performance cannot be stated beyond the site preparation facts. Installation, connection and control specifics must be taken from the 8890 GC site preparation checklist and the instrument manual for the delivered configuration.
Integration & Operating Notes
The specified 20 A power outlet current and 13.4 A current rating leave limited headroom on a shared branch. The analyzer should be placed on a circuit sized for its own draw so that oven and accessory loads do not trip the breaker during a run.
Operation outside the stated ambient range can affect retention-time stability and detector response in trace sulfur work, where small baseline shifts matter. The storage range of 40–70 °C applies only to non-operating transport and must not be used as an operating allowance.
Selection & Integration Q&A
Choose this configuration when the analytical target is sulfur species at trace levels. The sibling model is configured for measuring and monitoring greenhouse gas emissions. Both are built on the Agilent 8890A/B GC platform, so the decision is driven by the species to be quantified, not by hardware class.
The matched specs give 220 VAC at 13.4 A with a 20 A outlet requirement, but the 8890 site preparation checklist covers 120 VAC Americas and 220/230/240 VAC builds. Confirm the delivered configuration on the nameplate and size the branch circuit to the checklist before installation.
No maintenance schedule, consumables list or accessory set was supplied for this configuration; the only attached document is the 8890 GC site preparation checklist, which covers the data system PC and power cord options. Service intervals and consumables must be taken from the instrument manual for the delivered build.