Agilent Technologies Large Dry Scroll Pumps, TriScroll Vacuum Pumps
Agilent Technologies Large Dry Scroll Pumps, TriScroll Vacuum Pumps — Vacuum technologies with Motor power 0.119 kW, Pumping speed 3.6 m³/h.
The Agilent TriScroll is a large dry scroll vacuum pump with a 60 L/min pumping speed and 0.16 HP motor, operating on 100 VAC to reach a base pressure of 3.3 mbar. It is positioned within the Dry Scroll Pumps series as the larger-capacity modification relative to the small IDP series, intended for oil-free roughing and backing duties in analytical and laboratory vacuum systems.
Agilent Technologies Dry Scroll Pumps Series — Model Comparison & Selection
| Model | Motor power, kW | Pumping speed, m³/h | Base pressure, mbar |
|---|---|---|---|
| Large Dry Scroll Pumps, TriScroll Vacuum Pumps Current | 0.119 | 3.6 | 3.3 |
| Scroll Pumps IDP Series, Small, Dry & Hermetic Vacuum | 0.119 | 3.6 | 3.3 |
Full specifications
| Motor power | 0.16 HP |
| Pumping speed | 60 L/min |
| Base Pressure | 3.3 mbar |
| IDP-10 mfr | 3810 |
| IDP-10 with inlet isolation valve mfr | 3810 |
| IDP-7/10 tip seal replacement kit mfr | 3807 |
| Exhaust silencer kit mfr | 110 |
| Purge kit mfr | 3807 |
| Gas ballast kit mfr | 3807 |
| Inlet trap mfr | 25 |
| Vibration isolation kit mfr | 110 VIBISOKIT |
| IDP-35 mfr | 3835 |
| IDP-35 with Gauge mfr | 3835 |
| IDP-35 with Inlet Valve mfr | 3835 |
| IDP-35 with Inlet Valve and Gauge mfr | 3835 |
| Inlet HEPA filter, NW40 mfr | 40 |
| HEPA filter, NW25 mfr | 25 |
| IDP-45 mfr | 3845 |
| IDP-45 with Gauge mfr | 3845 |
| IDP-45 with Inlet Valve mfr | 3845 |
| IDP-45 with Inlet Valve and Gauge mfr | 3845 |
| IDP-15 mfr | 3815 |
| IDP-15 with inlet isolation valve mfr | 3815 |
| IDP-15 tip seal replacement kit mfr | 3815 |
| IDP-3 mfr | Vibration isolation kit kit |
| IDP-4 mfr | Replacement filter element element |
| IDP-7 mfr | Vibration isolation kit kit |
| inlet valve closing time mfr | 20 milliseconds |
| inlet valve opening time after power restore mfr | 10 seconds |
| tip seal replacement duration mfr | half an hour hour |
| IDP-4 maintenance duration mfr | 15...30 minutes |
| integrated Pirani gauge pressure range mfr | -4...1000 mbar |
| VPI valve isolation time mfr | 20 ms |
| green energy consumption mfr | 4 GWh |
| CO2 avoided mfr | 1350 Tons |
| solar energy generation mfr | 634 MWh |
| CO2 saved mfr | 214 tons |
| airfreight CO2 emission mfr | 600 kilometer |
| water saving mfr | 250 year |
| wastewater reduction mfr | 41 |
| energy reduction mfr | 35 MWh |
| CO2 emission reduction mfr | 12 ton |
| Operating voltage mfr | 100 VAC |
| IDP-35/IDP-45 supply frequency mfr | 50 Hz |
| startup current mfr | 10 A |
| cooling liquid reduction mfr | 20...40 percent |
Description
Construction and series positioning
- The TriScroll is a dry scroll pump, meaning the pumping mechanism uses orbiting and fixed scrolls without oil sealing, eliminating backstreaming contamination in the vacuum path.
- Within the Dry Scroll Pumps series, this model is designated as a large dry scroll pump; the sibling IDP series is explicitly described as small, dry and hermetic. The TriScroll therefore serves applications needing higher displacement than the small IDP variants.
- The only matched performance figures are a pumping speed of 60 L/min and a motor power of 0.16 HP; no curve points or multi-point performance data were supplied, so behavior across the pressure range cannot be characterized from the available facts.
Operating envelope
- Base pressure is stated as 3.3 mbar, which defines the lowest achievable inlet pressure for this configuration.
- Operating voltage is listed as 100 VAC. The document digest for the IDP family notes 50 Hz and 60 Hz operating points and 100–120/200–240 VAC motor variants across that family, but no such variant table is provided for this TriScroll model; the 100 VAC figure should be treated as the single stated operating voltage for this unit.
- No process-media, temperature, or duty-cycle limits were supplied in the verified facts.
Installation and control
- No actionable engineering facts were extracted from the attached document digests: the IDP family brochure digest contains no sections or actionable facts, and the corporate sustainability brochure covers no product models, sizes or ordering codes. Installation, connection and control specifics for this model therefore cannot be stated from the verified material.
- The card deliberately omits parameters not present in the facts (noise, weight, dimensions, ultimate pressure beyond the stated base pressure, and electrical current) rather than inferring them.
Integration & Operating Notes
The only stated operating voltage for this model is 100 VAC. The IDP family digest mentions 100–120/200–240 VAC motor variants across that family, but no variant table exists for this TriScroll unit, so the supply must be verified against the nameplate rather than assumed to accept 200–240 VAC.
Selection & Integration Q&A
Choose the TriScroll when the duty calls for a large dry scroll pump in the Dry Scroll Pumps series; the sibling IDP series is described as small, dry and hermetic. Both share 60 L/min and 0.16 HP in the supplied data, so the deciding factor is the large-versus-small series positioning, not the listed performance figures.
The stated operating voltage is 100 VAC, so the supply must match the nameplate; do not assume 200–240 VAC compatibility even though the IDP family digest lists such variants for that family. No controller, cable or mating-flange data was supplied, so those interfaces must be confirmed from the model-specific manual.
The verified facts contain no mounting orientation, ambient temperature or duty-cycle limits, and the attached document digests yielded no actionable engineering facts. These limits must be taken from the model-specific instruction manual before installation; they cannot be inferred from the 3.3 mbar base pressure or 60 L/min speed.
No maintenance intervals, error codes, cables, consumables or accessory part numbers are documented in the supplied facts or document digests. The base delivery content and service schedule must be confirmed against the model-specific manual and ordering information, which were not part of the verified material.