BINDER MKFT 240
BINDER MKFT 240 — Climate chambers with Temperature -70…180 °C.
The BINDER MKFT 240 is a 228 L alternating climate chamber with deep-temperature capability to -70 °C and humidity control from 10 to 98 % RH. It is the mid-size 400 V model in the MKFT series, positioned between the MKFT 115 and MKFT 720, and is distinguished by a 400 W maximum heat compensation load. It is used for cyclic temperature/humidity testing of components and materials under programmable profiles.
BINDER MKFT Series — Model Comparison & Selection
Full specifications
| Temperature | -70...180 °C |
| Interior volume | 228 L (MKFT240-400V) |
| Load per rack | 30 kg (MKFT240-400V) |
| Maximum heat compensation | 400 W |
| Nominal power | 6 kW (MKFT240-400V) |
| Article Number mfr | 9020 |
| Power frequency | 50 Hz (MKFT240-400V) |
| Rated voltage | 400 V |
| Unit fuse | 16.0 A (MKFT240-400V) |
| Humidity range | 10...98 % RH |
| Cooling down time from 180°C to -70°C mfr | 110 min |
| Humidity fluctuation with humidity dependent on set value mfr | 2.5 % r.F. |
| Average heating-up rate according to IEC 60068-3-5 between -40°C and 180°C mfr | 5.0 K/min |
Description
Construction and series positioning
- The MKFT 240 uses a 400 V, 3-phase supply (3 N/PE, 50 Hz) with a 6 kW nominal power and 16 A unit fuse, and is available as standard (MKFT240-400V, Art. No. 9020-0383) or with an integrated voltage and frequency changer (-C variant).
- Within the MKFT series, the 240 offers 228 L interior volume, between the 115 and 720 sizes; all share the -70…180 °C temperature range, but the 240 is specified for 30 kg load per rack and 400 W maximum heat compensation.
- The chamber is designed for alternating climate testing with program control and HIT Insulation®; it includes a rear power switch (from size 115 on) in addition to the main power switch.
Behavior under load and in different media
- Temperature uniformity is 0.2…1.8 K and fluctuation 0.1…0.5 K, depending on set value; with humidity active, the temperature range is restricted to 10…95 °C and fluctuation increases to 0.1…1.5 K.
- Humidity control covers 10…98 % RH with a fluctuation of 2.5 % RH; the humidity sensor has defined resistance limits for ammonia (max. 20 ppm workplace, 5500 ppm permanent) and ozone (0.1 ppm workplace, 0.5 ppm permanent), so process atmospheres must be checked.
- Average heating rate is 5.0 K/min between -40 °C and 180 °C, and cooling from 180 °C to -70 °C takes 110 min; average cooling rate between 180 °C and -40 °C is 4.2 K/min (per IEC 60068-3-5).
Installation, connection and control
- Water connections are required for humidification: freshwater supply (automatic via pipe or manual via internal can from size 115 on) and wastewater drain; a water circle lever for condensate recycling is optional.
- The MB2 chamber controller supports fixed-value, timer, time-program and week-program modes, with setpoint ramps/steps, tolerance ranges and section repetition; it also provides alarm and notification functions, user management with password protection, and a chart recorder display.
- Temperature safety devices include an over-temperature protective device (class 1) and a safety controller (class 2) with adjustable modes; an optional over/under temperature safety device class 2 is available.
- Electrical connection must account for the 400 V 3-phase supply and 16 A fusing; for the -C variant, the voltage and frequency changer installation is described separately.
Integration & Operating Notes
The chamber draws 6 kW nominal at 3 N/PE 400 V 50 Hz and must be protected by a 16 A fuse or circuit breaker. Verify that the site supply can deliver this without voltage drop, especially if other high-load equipment shares the circuit.
Although the chamber operates from -70 to 180 °C, humidity control is only permitted between 10 and 95 °C. Outside this range, humidity must be switched off to avoid condensation and sensor damage.
The chamber can compensate a maximum heat load of 400 W from the test specimen. Exceeding this may prevent the chamber from reaching or holding setpoints, especially at low temperatures, and can lead to extended recovery times.
Schedule maintenance at least once a year, including a leak test per Regulation (EU) 517/2014. Document the leak test in the service log book. Also plan steam humidifier maintenance annually, depending on water quality and usage.
After 8760 operating hours or two years, a service message is displayed. It reappears every two weeks after confirmation until reset by BINDER Service. Plan a service intervention to reset the message and perform required checks.
The steam humidifier requires maintenance at least annually, but the interval depends on water quality and the amount of steam produced. High mineral content or impurities may necessitate more frequent servicing.
From size 115 on, the chamber has a rear power switch in addition to the main power switch. For commissioning and troubleshooting, ensure both switches are in the ON position; otherwise the chamber will not power up.
Selection & Integration Q&A
Choose the MKFT 240 for a 228 L interior volume, balancing the smaller MKFT 115 and larger MKFT 720. All share the -70…180 °C range, but the 240 offers 30 kg per rack and 400 W heat compensation, suitable for mid-sized test loads.
The manual specifies annual maintenance and a leak test; the chamber is not intended for continuous operation at maximum load. Ensure the ambient temperature is within the specified range and keep the condenser fan grid clean, especially in dusty environments.
The base delivery excludes the recommended disinfectant spray (Art. No. 1002-0022), water connection kit, hose burst protection kit, and optional RS485 or analog outputs. Annual maintenance and leak test are required and not included.