Elmo Rietschle C-VLU 62
Elmo Rietschle C-VLU 62 — Claw Vacuum Pumps.
The C-VLU 62 is a dry-running claw vacuum pump with contact-free rotors synchronized by an oil-lubricated gear pair, available in standard CD and corrosion-protected XD versions. It delivers 65 m³/h suction capacity at 50 Hz and operates continuously between 700 mbar and 40 mbar (abs.), distinguishing it from larger siblings like the C-VLU 301 and 401. Its oil-free compression chamber and integral non-return valve make it suitable for dry processes requiring clean vacuum and backflow protection.
Elmo Rietschle C-VLU Series — Model Comparison & Selection
Full specifications
Description
Construction and Series Positioning
- Double-shaft rotary claw principle with contact-free, dry-running rotors; synchronization via oil-lubricated gear pair.
- Compression chamber separated from gearbox by special seals; integral non-return valve prevents back-ventilation after stop.
- Two versions: CD (standard, dry gases) and XD (corrosion-protective coating, suitable for water-damp gases/water vapour).
- Within the C-VLU series, the 62 is the smallest model (65 m³/h at 50 Hz); larger siblings include the C-VLU 301 (265 m³/h) and C-VLU 401.
Behavior Under Load and Media
- Continuous operation permitted between 40 mbar (abs.) and 700 mbar (abs.) inlet pressure; outside this range consult manufacturer.
- Suction capacity 65 m³/h at 50 Hz with unrestricted suction; refer to data sheet D 891 for capacity vs. pressure curves.
- Maximum permissible back pressure +30 mbar; exhaust line must be sized to avoid exceeding this.
- XD version handles water vapour; standard CD must not convey water vapour. For XD, condensate must be drained regularly from silencer.
- Frequent switching (≈10 times/hour) or high ambient/inlet temperatures may exceed motor winding and bearing temperature limits; consult manufacturer for such duty.
Installation, Connection, and Operation
- Install horizontally (max. 8° inclination), secure against tipping, with free access from all sides and at least 50 cm space for maintenance.
- Cooling air inlets/outlets at least 30 cm from walls; avoid intake of hot exhaust air from other machines.
- Electrical connection by qualified electrician per EN 60204; motor protection switch provided by user; motors IP55, insulation class F, comply with DIN EN 60034.
- Check rotation direction with phase sequence indicator: counter-clockwise viewed at motor blower; brief start max. 2 seconds to verify.
- Before shutdown >2 hours, run pump at 500 mbar (abs.) for 15–30 minutes with dry air to prevent condensate/impurity adhesion.
Integration & Operating Notes
Higher back pressure can cause overload, increased motor current, and potential mechanical damage. Exhaust lines should be sized with low resistance and routed to avoid restrictions; if process back pressure exceeds +30 mbar, contact the manufacturer for alternative solutions.
Wrong rotation direction can damage the pump and cause injury. Use a phase sequence indicator and briefly start the motor (max. 2 seconds) to confirm rotation is counter-clockwise when viewed at the motor blower. Correct wiring at the terminal box if needed.
Motors with AC apparent output >1.7 kVA, three-phase >5.2 kVA, or start currents >60 A are not designed for direct-on-line start. Use star-delta, soft starter, or frequency converter to limit starting torque and mechanical load. Verify motor data plate against supply.
Temperatures outside this range can affect lubrication, motor cooling, and material integrity. Ensure installation location has adequate ventilation and does not draw in hot exhaust air from other machines. For operation outside this range, consult manufacturer.
At elevations above 1000 m, reduced air density affects cooling and pumping performance. Contact manufacturer for installations above 1000 m to ensure proper sizing and cooling.
The vacuum pump does not have its own Emergency Stop or Emergency Off. The operator must integrate it into the plant's protection concept to provide emergency stop/off functionality, ensuring safe shutdown in case of process upset.
Selection & Integration Q&A
Choose C-VLU 62 for suction capacities around 65 m³/h at 50 Hz and continuous inlet pressures between 40 and 700 mbar (abs.). The C-VLU 301 offers 265 m³/h for higher flow; the C-VLU 401 is even larger. Select based on required pumping speed and operating pressure range.
Remove blind plugs/adhesive film from vacuum and exhaust connections. Connect pipes without excessive force or torque. The exhaust opening must not be closed or restricted; maximum permissible back pressure is +30 mbar. Ensure all connections are leak-tight and screw/flange connections are tight.
Install horizontally with max. 8° inclination, secure against tipping, and allow 50 cm maintenance space. Ambient/inlet temperature 5–40 °C. Avoid frequent switching (≈10 times/hour) as it may overheat motor; for such duty consult manufacturer. Above 1000 m altitude, output reduces.
The base delivery does not include intake filter (optional paper or polyester), motor protection switch (user-supplied), main switch (user-supplied), or condensate drain accessories for XD. Spare parts are listed in the separate Spare Parts List. Regular maintenance includes gearbox oil changes and oil level checks; if an optional intake filter is fitted, clean or replace its filter element as needed.