Elmo Rietschle VCD 400
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle VCD 400

Elmo Rietschle VCD 400 — Central Industrial & Medical Vacuum Systems with Motor power 9 kW, Noise level 75 dB, Pumping speed 480 m³/h.

The VCD 400 is an oil-flooded rotary vane vacuum pump in the V-VC series, configured with an 11 kW IE3 motor for 50 Hz operation and delivering 400 m³/h nominal suction capacity. It achieves an ultimate partial pressure of 0.1 mbar (0.5 mbar with gas ballast) and is positioned as the mid-size unit between the VCD 202 and larger V-VC 500/700/900 siblings. Its primary role is continuous duty in central industrial vacuum systems where high pumping speed at fine vacuum is required.

Motor power
9 kW
Noise level
75 dB
Pumping speed
480 m³/h
Ultimate pressure
0.1 mbar
Weight
357 kg

Elmo Rietschle VCD Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBPumping speed, m³/hUltimate pressure, mbarWeight, kgCurrent, A
VCD 400 Current 975120.135710.5–18.1
VCD 202 46924031958.2–14.3
VCD 40 1.162400.5552.34–4.07

Full specifications

Core Performance & Functional Specifications
Motor power 9.0 kW (50 Hz)
Noise level 73 dB (50 Hz)
60 Hz: 75 dB
Pumping speed 12 l
50 Hz: 400 m³/hour · 60 Hz: 480 m³/hour
Ultimate pressure 0.1 mbar
with gas ballast: 0.5 mbar
Rotational speed 975 rpm (50 Hz)
Series mfr V-VC 400 | 500 | 700 | 900
Nominal suction capacity mfr 400 m3/h (50 Hz)
Nominal suction capacity mfr 480 m3/h (60 Hz)
Ultimate vacuum (with gas ballast) mfr 0.5 (10) mbar
Motor version mfr UN IE3 (50 Hz)
Motor diameter (Øw*) mfr 347 mm (50 Hz)
Motor speed mfr 1170 min-1 (60 Hz)
Motor notes mfr UR, CSA, EAC
Motor diameter (Øw*) mfr 366 mm (60 Hz)
Vacuum connection R mfr G 3
Exhaust R1 mfr Rp 3
Nennsaugvermögen / Nominal suction capacity mfr 400 m3/h (50 Hz)
Nennsaugvermögen / Nominal suction capacity mfr 480 m3/h (60 Hz)
Enddruck (mit Gasballast) / Ultimate vacuum (with gas ballast) mfr 0.5 (10) mbar
Motor version mfr HM IE3
Diameter Øw* mfr 347 mm
a1 mfr 864 mm
a2 mfr 787 mm
b mfr 931 mm
c mfr 606 mm
d mfr 340 mm
e mfr 415 mm
f mfr 380 mm
g mfr 540 mm
h mfr 330 mm
l mfr 310 mm
o mfr 410 mm
p mfr 515 mm
q mfr 372 mm
r mfr 405 mm
øs mfr M12
t mfr M 40 x 1,5
u mfr 40 mm
R (Vakuum-connection / Vacuum connection) mfr G 3
R1 mfr Rp 3
Dimensions, Weight & Mechanical Design
Weight 357 kg
Height 606 mm
Length 1390 mm
Width 347 mm
max. Weight without motor mfr 357 kg
Motor weight mfr 114 kg (50 Hz)
Motor total length (a*) mfr 1390 mm (50 Hz)
Motor weight mfr 170 kg (60 Hz)
Motor total length (a*) mfr 1450 mm (60 Hz)
Dimension a1 mfr 864 mm
Dimension a2 mfr 787 mm
Dimension b mfr 931 mm
Dimension c mfr 606 mm
Dimension d mfr 340 mm
Dimension e mfr 415 mm
Dimension f mfr 380 mm
Dimension g mfr 540 mm
Dimension h mfr 330 mm
Dimension l mfr 310 mm
Dimension o mfr 410 mm
Dimension p mfr 515 mm
Dimension q mfr 372 mm
Dimension r mfr 405 mm
Dimension øs mfr M12
Dimension t mfr M 50 x 1,5
Dimension u mfr 40 mm
max. weight ohne Motor / max. Weight without motor mfr 357 kg
Motor weight mfr 114 kg
Dimension a1 (alt var) mfr 864 mm
Dimension a2 (alt var) mfr 787 mm
Dimension b (alt var) mfr 931 mm
Dimension R mfr G 3
Dimension R1 mfr Rp 3
Electrical, Power & Drive Specifications
Current 18.1 / 10.5 A (50 Hz)
Voltage 400 / 690 V (50 Hz)
Motor voltage mfr 220 / 380 | 440 V ± 10 % (60 Hz)
Motor current mfr 42.8 / 24.8 | 21.4 A (60 Hz)
Motors HM IE3 weight (alt var) mfr 114 kg
Interfaces, Connections & Control
Inlet connection M 40 x 1.5
Materials, Media & Process Compatibility
Oil capacity mfr 12 l
Öleinfüllmenge / Oil capacity mfr 12 l
Operating Conditions, Environment & Protection
Average noise level mfr 75 dB(A) (60 Hz)
Mittlerer Schalldruckpegel / Average noise level mfr 73 dB(A) (50 Hz)
Mittlerer Schalldruckpegel / Average noise level mfr 75 dB(A) (60 Hz)

Description

Construction and series positioning

Performance and operating behavior

Installation, connection and control

Integration & Operating Notes

Electrical
Motor terminal voltage must match the selected winding connection

The 50 Hz motor is rated 400/690 V ±10 % and the 60 Hz motor 220/380–440 V ±10 %. Connecting the motor to a supply outside these windows, or to the wrong winding configuration, will cause overheating or loss of torque. Verify the actual plant voltage and the motor nameplate link arrangement before first start.

Technical Data Sheet — vacuum pump DE/EN, Motor Data
Process Limits
Gas ballast raises ultimate pressure from 0.1 to 0.5 mbar

When the gas ballast is opened to handle condensable vapors, the achievable ultimate vacuum degrades to 0.5 mbar. Do not specify the pump for 0.1 mbar end-vacuum processes while relying on continuous gas ballast operation; either accept the higher pressure or use a cold trap/condenser upstream.

Technical Data Sheet — vacuum pump DE/EN, Performance Data
Maintenance
Oil charge is 12 l; oil condition governs service interval

The pump holds 12 l of oil. In industrial vacuum service, oil is degraded by condensable vapors and particulate ingress; the gas ballast helps but does not eliminate oil change needs. Establish an oil sampling routine and replace oil when it darkens or emulsifies. Oil and oil filters are consumables not included in base delivery.

Technical Data Sheet — vacuum pump DE/EN, Oil Capacity

Selection & Integration Q&A

When should I choose the VCD 400 over the VCD 202 or the larger V-VC 500/700/900 models?

Pick the VCD 400 when your required suction capacity is around 400 m³/h at 50 Hz and ultimate pressure near 0.1 mbar. The VCD 202 is smaller and suits lower flow; the V-VC 500/700/900 are larger frames for higher flows. The VCD 400 is the mid-size compromise with a 9.0 kW IE3 motor.

What motor supply and protection must be provided for the VCD 400?

The 50 Hz UN IE3 motor requires a 3-phase supply matching 400/690 V ±10 % and draws 18.1/10.5 A depending on connection. Provide a motor protection switch or VFD rated for at least 9.0 kW and set overload to the nameplate current for the chosen winding. The 60 Hz variant needs 220/380–440 V and draws up to 42.8 A.

What consumables and accessories are not included in the base delivery?

The base pump delivery excludes oil (12 l charge required), inlet filters, exhaust filters, gas ballast valve (if not factory-fitted), and electrical cables. The technical data sheet lists motor variants and a water-cooled option separately; confirm whether the gas ballast and IE3 motor are included in your specific order code.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — vacuum pump DE/EN)
Datasheet ·306,7 КБ ·4 pp.
View PDF