Peter Huber Kältemaschinenbau HB720 Umwälz-Heizgerät
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau HB720 Umwälz-Heizgerät

Peter Huber Kältemaschinenbau HB720 Umwälz-Heizgerät — Thermostatic baths.

The HB720 is a 72 kW three-phase immersion heating circulator for external open operation, delivering 60–250 °C with a magnetically coupled stainless-steel pressure pump (200 l/min, 5.5 bar). It has no expansion tank and no active refrigeration, so minimum temperature depends on ambient and application heat loss. It serves high-capacity external heating loops in industrial processes.

Direct drop-in replacements

Eppendorf
MixMate ®
82%
match
⚖️ Compare

Peter Huber Kältemaschinenbau Umwaelz Heizgeraete Series — Model Comparison & Selection

Model Dimensions w d hPower supplyPump connectionPump typeHeating capacity, WAmbient temperature limit, °C
HB720 Umwälz-Heizgerät Current 800 x 1007 x 1607400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st720005–40
HB120 Umwälz-Heizgerät 479 x 539 x 695380-460V 3~ 50/60HzM30x1, 5 AG malemagnetically coupled, st—5–40
HB240 Umwälz-Heizgerät 570 x 700 x 1171400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st240005–40
HB480 Umwälz-Heizgerät 570 x 700 x 1171400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st480005–40
HB60 Umwälz-Heizgerät 323 x 451 x 498400V 3~N 50HzM30x1, 5 AG malePressure pump, speed not60005–40

Full specifications

Core Performance & Functional Specifications
Dimensions (w × D × H) 800 x 1007 x 1607 mm
Heating capacity 72 kW
Pump connection M38x1, 5 AG male
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range 60...250 °C
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Standards, Safety & General Data
Safety class II / FL

Description

Construction and series positioning

Behavior under load and media

Installation, connection and operation

Integration & Operating Notes

Process Limits
Minimum 60 °C depends on application heat loss and ambient

The unit has no active refrigeration, so 60 °C is reachable only if ambient is below 60 °C and the application heat loss lies between 0.1 kW and 2.8 kW depending on model. Size the external circuit and insulation so the heat loss stays in this band, otherwise the minimum temperature cannot be attained.

Datasheet HB720 Immersion Circulator, page 2
Electrical
Plug and cable scope depends on current draw above or below 63 A

Three-phase devices drawing less than 63 A are supplied with cable but without a plug, so the customer must provide and fit a suitable plug. Devices drawing more than 63 A are supplied without cable and without plug, requiring full customer-side power cabling and planning.

Datasheet HB720 Immersion Circulator, page 2
Control & I/O
Set adjustable overtemperature protection to suit the application

The unit provides adjustable overtemperature protection according to DIN 12876. The trip limit must be configured for the specific external application so that the connected circuit is protected against overheating; this is a safety setting, not a fixed factory value.

Datasheet HB720 Immersion Circulator, page 1
Cooling & Media
Pump head and flow must cover the external circuit pressure drop

The circulation pump delivers up to 200 l/min at up to 5.5 bar. Verify that this head and flow are sufficient for the pressure drop of the external circuit, and match hoses or adapters to the M38x1.5 male pump connection.

Datasheet HB720 Immersion Circulator, page 1

Selection & Integration Q&A

When should I choose the HB720 rather than a smaller sibling such as the HB480 or HB240?

Pick the HB720 when the process needs up to 72 kW heating and the 60–250 °C range with a 200 l/min, 5.5 bar pump. Smaller siblings suit lower heat loads; the HB720 is the largest heating-capacity modification in the series.

What must the external circuit and its connections provide for this unit?

The application must be an external open circuit that accommodates fluid volume changes, since there is no expansion tank. Hoses or adapters must match the M38x1.5 male pump connection and handle up to 200 l/min at 5.5 bar.

What site and duty conditions does the installation manual impose?

Ambient must stay 5–40 °C, the location must be dry indoor due to IP20, and the 400 V 3~ 50 Hz supply must not combine voltage and frequency deviations in opposite directions beyond ±10%.

What is not included in the base delivery that I must plan for?

Depending on current draw, the unit ships with cable but no plug (below 63 A) or without cable and plug (above 63 A), so the customer must provide the plug and, above 63 A, the full power cabling.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
HB720 Immersion Circulator
Datasheet ·17,6 КБ ·2 pp.
View PDF