Nabertherm F 110
Nabertherm F 110 — Fusing furnaces.
The F 110 is a top-loading fusing furnace with a 930 × 590 × 230 mm chamber and 950 °C maximum temperature, positioned above the F 30 and F 75 siblings in the series. Its 7.5 kW three-phase connection and 110 kg construction suit glass fusing and similar processes requiring a wide, shallow heated volume.
Nabertherm Top Loader as Fusing Furnaces | Nabertherm Series — Model Comparison & Selection
Full specifications
| Electrical connection | 3-phase |
| Nominal power | 7.5 kW |
| Floor space mfr | 0.47 |
| Inner dimensions (W × D × H) mfr | 930 × 590 × 230 mm |
| Outer dimensions (W × D × H) mfr | 1130 × 1000 × 690 mm |
| Weight | 110 kg |
| Max temperature | 950 °C |
Description
Construction and series positioning
- Top-loader architecture with a rectangular chamber of 930 × 590 × 230 mm (W × D × H), giving a wide, shallow working volume suited to flat workpieces.
- Outer dimensions of 1130 × 1000 × 690 mm and a floor space of 0.47 m²; unit weight is 110 kg.
- Within the series, the F 110 sits above the F 30 and F 75 in chamber size; it is the larger modification for wider loads rather than higher temperature.
Thermal behavior and limits
- Maximum operating temperature is 950 °C, with a nominal connected power of 7.5 kW.
- No digitized heating or cooling curves are available for this model; thermal performance must be taken from the controller documentation and application trials rather than from published curve data.
Electrical and control integration
- The furnace is wired for a 3-phase supply at 7.5 kW; the exact voltage and current per phase are not stated in the verified facts and must be confirmed against the nameplate before installation.
- Controller functions, process-data storage and recorder options are described in the separate process-control document (series 500 and MyNabertherm app); the furnace model itself does not appear in that document, so controller configuration is project-specific.
Integration & Operating Notes
The verified data state only '3-phase' and 7.5 kW; phase voltage, full-load current and recommended breaker size are not given. The installing engineer must read the nameplate and the wiring diagram supplied with the unit, because a 7.5 kW load at 400 V and at 230 V three-phase draws very different currents and cable sizes.
The footprint is 0.47 m² with outer dimensions of 1130 × 1000 × 690 mm. Because the unit is a top loader, the lid opens upward; overhead clearance and free access to all four sides must be reserved for loading and for service, in addition to the stated floor space.
The maximum temperature is 950 °C. Exceeding it risks damage to the heating elements and insulation; process recipes and controller setpoints must be limited to this value, and any over-temperature protection should be set below it.
The process-control document covers the series 500 controllers and the MyNabertherm app, including process-data storage and temperature-uniformity instrumentation. The F 110 itself is not listed in that document, so the controller variant, interface and recorder options must be specified per order and checked against the delivered wiring.
Selection & Integration Q&A
Choose the F 110 when the workload needs the larger 930 × 590 × 230 mm chamber; the F 30 and F 75 offer smaller chambers. All three share the 950 °C class, so the decision is driven by part size and batch volume, not by temperature.
The unit is a 3-phase, 7.5 kW load, but the verified data do not state phase voltage or full-load current. Size the cable, breaker and isolator from the nameplate and wiring diagram supplied with the furnace, not from the power rating alone.
The verified facts list only the furnace itself: no controller, recorder, thermocouple, cable or process-data software is confirmed as included. The series 500 controller and MyNabertherm app are described in a separate document and must be specified as options with the order.