Nabertherm F 75
Nabertherm F 75 — Fusing furnaces.
The F 75 is a top-loading fusing furnace with a 750 × 520 × 230 mm chamber and 950 °C maximum temperature, positioned between the F 30 and F 110 in the series. Its 5.5 kW three-phase connection and 95 kg weight suit bench or floor installation where batch fusing of glass or similar materials is required.
Nabertherm Top Loader as Fusing Furnaces | Nabertherm Series — Model Comparison & Selection
Full specifications
| Electrical connection | 3-phase |
| Nominal power | 5.5 kW |
| Floor space mfr | 0.33 |
| Inner dimensions (W × D × H) mfr | 750 × 520 × 230 mm |
| Outer dimensions (W × D × H) mfr | 945 × 930 × 690 mm |
| Weight | 95 kg |
| Max temperature | 950 °C |
Description
Construction and series positioning
- The F 75 is a top-loader with a rectangular chamber of 750 × 520 × 230 mm (W × D × H), giving a relatively wide and shallow working volume compared with the smaller F 30 and larger F 110 siblings.
- Outer dimensions are 945 × 930 × 690 mm, and the unit weighs 95 kg; floor space is 0.33 m². The top-loading architecture exposes the full chamber opening for loading and unloading, which is typical for fusing operations where parts are laid flat.
- The 950 °C maximum temperature places this model in the fusing range, below high-temperature chamber furnaces but above standard drying ovens.
Behavior and process role
- With 5.5 kW nominal power on a three-phase supply, the F 75 is intended for batch processes that require uniform heating across a large flat area rather than rapid cycling.
- No digitized curve points were supplied for this model, so heating/cooling rates and uniformity data cannot be stated here; the controller documentation covers general process control but does not include model-specific thermal curves.
- The shallow 230 mm chamber height limits the height of fixtures and loads; the wide 750 mm width and 520 mm depth accommodate multiple smaller items side by side.
Control and documentation context
- The attached controller digest describes the Nabertherm 500 series and MyNabertherm app, covering process data storage and temperature uniformity instrumentation (AMS2750F types), but it does not list model-specific settings for the F 75.
- No installation or connection details specific to the F 75 appear in the supplied document digests; the foundry, dental, and fiber-optics brochures cover other product lines and should not be used to infer F 75 wiring or control configuration.
Integration & Operating Notes
The furnace is specified for a three-phase electrical connection with 5.5 kW nominal power. The upstream protection, cable cross-section, and disconnect must be selected for this load; no single-phase option is stated in the verified facts, so a three-phase feed is mandatory.
The 945 × 930 × 690 mm outer envelope and 0.33 m² floor space define the footprint. Because the unit is a top loader, clearance above the chamber must be reserved for loading and for the lid or lift mechanism; the verified facts do not state side or rear clearances, so these must be confirmed against the installation manual.
The maximum temperature is 950 °C. Operating above this limit risks damage to the heating elements and chamber insulation. The controller setpoint and over-temperature protection must be configured so that the 950 °C ceiling is never exceeded during fusing cycles.
Selection & Integration Q&A
Choose the F 75 when the batch footprint needs the 750 × 520 mm chamber but the load height stays under 230 mm. The F 30 is smaller; the F 110 is larger. The F 75 sits between them in chamber area and power, so select it when the F 30 is too small and the F 110 would be underloaded.
The F 75 is a three-phase unit rated 5.5 kW. The facility must provide a three-phase feed sized for this load, with upstream protection and cable cross-section selected accordingly. No single-phase variant is stated in the verified facts, so a three-phase supply is required.
The verified facts do not list maintenance intervals, consumables, or included accessories for the F 75. The controller documentation describes optional recorder and process-data functions but does not assign them to this model. Maintenance schedule and accessory scope must be confirmed from the furnace manual and order documentation.