Nabertherm GF 75
Nabertherm GF 75 — Fusing.
The GF 75 is a fixed-table fusing furnace with a 620 × 620 × 310 mm chamber and 900 °C maximum temperature, powered by a 3.6 kW single-phase connection. It sits at the smaller end of the GF series, below the GF 240, and is intended for fusing processes that require a flat, stationary hearth rather than a tilting or rotating table.
Nabertherm GF Series — Model Comparison & Selection
| Model | Electrical connection | Max temperature, °C | Weight, kg |
|---|---|---|---|
| GF 75 Current | 1-phase | 900 | 180 |
| GF 240 | 3-phase | 950 | 275 |
Full specifications
| Electrical connection | 1-phase |
| Electrical connection | 1-phase |
| Nominal power | 3.6 kW |
| Floor space mfr | 0.38 |
| Inner dimensions (W × D × H) mfr | 620 × 620 × 310 mm |
| Outer dimensions (W × D × H) mfr | 1070 × 950 mm |
| Weight | 180 kg |
| Weight | 180 kg |
| Max temperature | 900 °C |
| Max temperature | 900 °C |
Description
Construction and series positioning
- The GF 75 uses a fixed table design; the chamber measures 620 × 620 × 310 mm (W × D × H) and the outer envelope is 1070 × 950 mm, with a floor space of 0.38 m².
- Within the GF series, the GF 75 is the smaller modification; the GF 240 is the larger sibling. The fixed table distinguishes this model from any tilting or movable-table variants in the broader fusing furnace range.
- The unit weighs 180 kg and is designed for stationary installation.
Thermal and electrical behavior
- Maximum operating temperature is 900 °C, achieved with a nominal power of 3.6 kW from a single-phase electrical connection.
- No digitized curve points or additional thermal performance data are available for this model; behavior under load should be derived from the controller settings and process requirements rather than from published curves.
Control and operation
- The attached controller documentation covers the Nabertherm series 500 controllers and the MyNabertherm app, including process data storage and temperature uniformity instrumentation per AMS2750F. These controller functions are available for integration but are not specified as included in the base GF 75 delivery.
- No furnace-specific manual digest is available for the GF 75; installation, connection, and operating specifics must be taken from the general controller documentation and standard Nabertherm practice for this furnace class.
Integration & Operating Notes
The GF 75 draws 3.6 kW on a single-phase connection. The supply circuit, protective device, and wiring must be sized for the full nominal current with appropriate derating; sharing the circuit with other high-load equipment may cause voltage drop and control instability.
The maximum temperature is 900 °C. Operating above this limit risks damage to the heating elements and insulation. The controller should be configured with an appropriate setpoint limit to prevent accidental overshoot.
Selection & Integration Q&A
Choose the GF 75 when the workload fits within its 620 × 620 × 310 mm chamber and the 900 °C maximum is sufficient. The GF 240 offers a larger chamber for bigger batches; select it when the GF 75 chamber size or 3.6 kW power is limiting.
The GF 75 requires a single-phase supply capable of delivering 3.6 kW. A dedicated circuit with a protective device rated for the nominal current and wiring sized for the load is necessary; consult local electrical codes for disconnection and grounding requirements.
No furnace-specific maintenance schedule is provided in the available documents. Controller options, the MyNabertherm app, and AMS2750F instrumentation are documented separately and are not part of the base delivery. Regular inspection of heating elements and thermocouples is recommended per standard practice.