Nabertherm HT 450/16
Nabertherm HT 450/16 — High-temperature furnaces.
The HT 450/16 is a 450-litre high-temperature chamber furnace with fiber insulation and molybdenum disilicide heating elements, rated to 1600 °C. Its 500 × 1150 × 780 mm chamber and 65 kW connected load on 3-phase supply distinguish it as the largest-volume model in the HT series. It is intended for high-temperature batch processing where uniform heating of bulky loads is required.
Nabertherm High-Temperature Furnaces with Molybdenum Disilicide Heating Elements with Fiber Insulation up to 1800 °C | Nabertherm Series — Model Comparison & Selection
Full specifications
| Chamber volume | 450 l |
| Chamber volume | 450 l |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Connected mfr | 65.0 |
| Inner dimensions (W × D × H) mfr | 500 × 1150 × 780 mm |
| Outer dimensions (W × D × H) mfr | 1380 × 1820 × 2570 mm |
| Weight | 1570 kg |
| Weight | 1570 kg |
| Max temperature | 1600 °C |
| Max temperature | 1600 °C |
Description
Construction and series positioning
- The HT 450/16 uses fiber insulation and molybdenum disilicide (MoSi2) heating elements, enabling a maximum working temperature of 1600 °C.
- With a 450-litre chamber (500 × 1150 × 780 mm), it is the largest-volume model among the listed siblings (HT 29/17, HT 160/17, HFL 16/17, HFL 160/17), which offer smaller chambers and/or higher 1700 °C limits.
- Outer dimensions of 1380 × 1820 × 2570 mm and a weight of 1570 kg require a reinforced floor and sufficient ceiling clearance for installation.
Behavior under load
- No digitized curve points are available for this model; heating and cooling behavior cannot be quantified from the supplied facts.
- The 65 kW connected load on a 3-phase supply indicates the electrical infrastructure required for full-power operation.
Control and operation
- The supplied document digests do not contain model-specific controller or installation details for the HT 450/16; controller options from the general Nabertherm 500 series and MyNabertherm app are not confirmed for this model in the provided facts.
Integration & Operating Notes
The furnace draws 65 kW on a 3-phase connection. The site electrical supply, cabling, and protection devices must be sized for this load; an undersized supply will prevent the furnace from reaching its rated 1600 °C or cause nuisance tripping.
The unit weighs 1570 kg and stands 2570 mm tall with outer dimensions of 1380 × 1820 × 2570 mm. The installation floor must support this load, and ceiling height plus clearance for lid or door operation must be verified before positioning.
The MoSi2 heating elements and fiber insulation are rated for a maximum of 1600 °C. Process recipes must not exceed this limit; doing so risks element degradation and insulation damage. Sibling models with /17 suffix reach 1700 °C but have smaller chambers.
The attached document digests describe general Nabertherm controller series 500 and MyNabertherm app functions but do not confirm which controller is fitted to the HT 450/16. The actual controller model, interface options, and data-logging capability must be confirmed with the order documentation.
Selection & Integration Q&A
Choose the HT 450/16 when the batch requires a 450-litre chamber (500 × 1150 × 780 mm) and temperatures up to 1600 °C. Select a smaller HT model for lower-volume loads, or an HFL/17 variant if 1700 °C is needed, accepting reduced chamber size.
The furnace requires a 3-phase supply sized for a 65 kW connected load. Cabling, switchgear, and overcurrent protection must be rated accordingly; the site supply capacity should be verified before installation to avoid voltage drop or tripping at full power.
The supplied documents do not specify maintenance intervals, consumables, or included accessories for the HT 450/16. Controller options, recorders, and interface cables described in general Nabertherm literature are not confirmed as part of the base delivery and must be verified with the order.