Nabertherm LH 60/12
Nabertherm ·Made in Germany · In Active Production

Nabertherm LH 60/12

Nabertherm LH 60/12 — Furnaces Protective Gas Boxes.

The LH 60/12 is a 60-litre chamber furnace with brick insulation, rated to 1200 °C and powered from a 3-phase supply. Its 400 × 400 × 400 mm chamber distinguishes it from the 30-litre LH 30/12 and the larger 120- and 216-litre siblings in the LH/12 series. It serves as a general-purpose batch furnace for heat treatment under protective gas.

Nabertherm LH Series — Model Comparison & Selection

Model Chamber volume, LElectrical connectionMax temperature, °CWeight, kg
LH 60/12 Current 603-phase1200300
LH 120/12 1203-phase1200410
LH 30/14 303-phase21400200

Full specifications

Core Performance & Functional Specifications
Chamber volume 60 l
Chamber volume 60 l
Chamber volume 60 l
Chamber volume 60 l
Chamber volume 60 l
Electrical connection 3-phase
Electrical connection 3-phase
Electrical connection 3-phase
Electrical connection 3-phase
Electrical connection 3-phase
Connected mfr 8
Inner dimensions (W × D × H) mfr 400 × 400 × 400 mm
Outer dimensions (W × D × H) mfr 790 × 1180 × 1370 mm
Dimensions, Weight & Mechanical Design
Weight 300 kg
Weight 300 kg
Weight 300 kg
Weight 300 kg
Weight 300 kg
Operating Conditions, Environment & Protection
Max temperature 1200 °C
Max temperature 1200 °C
Max temperature 1200 °C
Max temperature 1200 °C
Max temperature 1200 °C

Description

Construction and series positioning

Thermal behaviour

Control and documentation

Integration & Operating Notes

Process Limits
Do not exceed the 1200 °C chamber rating

The LH 60/12 is rated to a maximum chamber temperature of 1200 °C. Setpoint and over-temperature limits in the controller must be configured so that the brick insulation and heating elements are never driven above this value, which would shorten element and lining life.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the LH 60/12 rather than the LH 30/12, LH 120/12 or LF 60/14?

Pick the LH 60/12 when a 400 × 400 × 400 mm, 60-litre chamber at up to 1200 °C is enough. Step down to the LH 30/12 for smaller batches, up to the LH 120/12 or LH 216/12 for larger loads, or to the LF 60/14 if 1400 °C is required.

What supply and upstream protection does the 3-phase connection require?

The unit is 3-phase, but the factory sheet lists a connected value of 8 without a unit. Read the nameplate for the actual kW and full-load current, then size the feeder, fuses and isolator to that figure; do not size from the catalog number alone.

What is supplied with the base unit and what must be ordered separately?

The verified facts list no included accessories, controller model or recorder. Controller options, process-data storage and AMS2750F instrumentation are covered in the separate controller digest, so the controller, recorder and any gas fittings should be confirmed against the order.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF