Nabertherm LHT 02/17 LB Speed
Nabertherm LHT 02/17 LB Speed — Dental sintering furnaces.
The LHT 02/17 LB Speed is a single-phase dental sintering furnace with a Ø 115 mm lifting-table work space and 1650 °C maximum temperature, rated 3.6 kW. Its 75 kg table load and 20 K/min heating rate to 1000 °C distinguish it from the smaller LHT 01/17 LB Speed sibling. It is intended for sintering zirconia and other dental ceramics under programmable time-temperature profiles.
Nabertherm LHT Series — Model Comparison & Selection
| Model | Maximum load, kg | Weight, kg | Electrical connection | Max temperature, °C |
|---|---|---|---|---|
| LHT 02/17 LB Speed Current | 75 | 55 | 1-phase | 1650 |
| LHT 01/17 LB Speed | 30 | 45 | 1-phase | 1650 |
Full specifications
| Chamber volume | 2 l |
| Electrical connection | 1-phase |
| Electrical connection | 1-phase |
| Maximum load | 75 kg |
| Nominal power | 3.6 kW |
| Work space dimensions2 in mm mfr | 140 |
| Max. heating rate up to 1000 °C mfr | 20 |
| Outer dimensions (W × D × H) mfr | 390 × 590 × 785 mm |
| Connected mfr | 3.6 |
| Weight | 55 kg |
| Weight | 55 kg |
| Charging area in mm mfr | 135 |
| Max temperature | 1650 °C |
| Max temperature | 1650 °C |
Description
Construction and series positioning
- Lifting-table architecture: the charge sits on a Ø 135 mm charging area that is raised into the heated chamber; work space is Ø 115 mm with 140 mm usable height.
- Outer dimensions 390 × 590 × 785 mm (W × D × H), unit weight 55 kg.
- Within the LHT../17 LB Speed series, this is the larger of the two listed models: the LHT 01/17 LB Speed is the smaller sibling; the 02 code denotes the larger work space and 75 kg table load.
- Electrical connection is 1-phase; nominal power 3.6 kW. No voltage or frequency is stated in the verified facts, so the supply configuration must be confirmed against the nameplate before installation.
Thermal behavior
- Maximum temperature 1650 °C; the only published rate is 20 K/min maximum heating rate up to 1000 °C. No curve points are available, so no cooling or controlled-rate behavior beyond this figure should be assumed.
- The 75 kg maximum load applies to the lifting table; the charge plus any sintering support/settling media must stay within it.
Control and operation
- The attached controller digest covers the Nabertherm 500-series controllers and the MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but it prints no model-specific parameters for this furnace. Programmer/recorder capability therefore depends on the controller option ordered and must be specified at order.
- The dental brochure in the document set covers the LHT../17 D and LHT 01/16 Turbo Fire sintering furnaces, not this LB Speed model; its content should not be transferred to this unit.
Integration & Operating Notes
The 75 kg maximum load is the limit for the lifting table. Sintering supports, settling media and the workpiece all count toward it; exceeding it loads the lift mechanism and can distort the table travel into the heated chamber.
The only published rate is a maximum of 20 K/min up to 1000 °C. Programs written for faster ramps or for rates above 1000 °C have no verified basis for this model and should be validated on the unit before production use.
Selection & Integration Q&A
Choose the 02 when the charge and its sintering supports approach or exceed the smaller sibling's capacity: this model offers a Ø 115 mm work space, 140 mm usable height and a 75 kg table load at 3.6 kW. The 01 is the smaller unit of the series; no further data on it is verified here.
A 1-phase supply sized for 3.6 kW nominal power, with voltage and frequency taken from the unit nameplate because the verified facts give none. Controller functions such as programming, process-data storage and recorder outputs come from the ordered 500-series controller option, not from the furnace model itself.
The verified facts and attached document digests contain no maintenance schedule, service intervals, error codes or accessory list for the LHT 02/17 LB Speed. Consumables, cables and controller options should be confirmed with the supplier at order; nothing beyond the furnace itself can be assumed as included.