Nabertherm LHT 04/17 — High-temperature furnaces.
The LHT 04/17 is a 4-litre high-temperature chamber furnace with MoSi₂ heating elements, rated to 1750 °C from a 1-phase supply. Its 160 × 175 × 160 mm chamber and 39 kg frame place it as the smallest air-atmosphere unit in the LHT ../17 series, distinguished from the D siblings by the absence of a vacuum/pressurised retort. It serves laboratory sintering, annealing and melting of small ceramic or metallic samples.
Nabertherm LHT Series — Model Comparison & Selection
Full specifications
| Chamber volume | 4 l |
| Electrical connection | 1-phase |
| Connected mfr | 3.40 |
| Heating time mfr | 90 min |
| Inner dimensions (W × D × H) mfr | 160 × 175 × 160 mm |
| Outer dimensions (W × D × H) mfr | 450 × 475 mm |
| Weight | 39 kg |
| Max temperature | 1750 °C |
Description
Construction and series position
The LHT 04/17 is the base 4-litre member of the LHT ../17 family, which also includes the 1-, 2-, 3- and 8-litre sizes (LHT 01/17 D, LHT 02/17, LHT 03/17 D, LHT 08/17). The 'D' suffix on the 01 and 03 marks the vacuum/pressurised variants; this model carries no D, so it is the open-air chamber version. The chamber measures 160 × 175 × 160 mm (W × D × H) inside a 450 × 475 mm outer envelope, and the whole unit weighs 39 kg. Heating is by MoSi₂ elements, which are the reason the series reaches 1750 °C rather than the ~1200–1400 °C ceiling of metallic-element furnaces.
Thermal behaviour
- Maximum working temperature: 1750 °C.
- Heating time to the top of the range: 90 min.
- Connected load: 3.40 (as printed; the unit is not stated in the source and is therefore not asserted here).
- Electrical connection: 1-phase.
No digitised curve points were supplied, so no heating-rate-versus-temperature profile can be quoted; the 90-minute figure is the only thermal-rate fact available and should be treated as a nominal full-range ramp.
Control and operation
The attached controller digest covers the Nabertherm 500-series controllers and the MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but it prints no model-specific wiring or setpoint tables. The furnace is therefore specified here only as a 1-phase, 1750 °C chamber; controller model, thermocouple type and over-temperature protection must be fixed at order from the controller series, not inferred from this card.
Integration & Operating Notes
The furnace is a 1-phase load with a connected figure of 3.40 printed without a unit in the source. The installing engineer must confirm the unit (kW or A) against the nameplate before sizing the branch circuit, breaker and cable, because the digest does not state it and a 4-litre 1750 °C chamber can draw a substantial single-phase current.
MoSi₂ elements and the chamber insulation are rated to a 1750 °C maximum. Running above this shortens element life and can damage the refractory; the controller's over-temperature limit should be set below 1750 °C so a runaway setpoint cannot drive the chamber past the element rating.
This is the non-D variant of the LHT ../17 series, so it has no vacuum or pressurised retort. Processes requiring reduced pressure, inert-gas purging or pressure-assisted sintering must use the D siblings (LHT 01/17 D, LHT 03/17 D) instead; forcing a sealed atmosphere on this chamber is outside its construction.
MoSi₂ heating elements oxidise and increase in resistance over service life; the controller must be able to compensate for rising element resistance, and elements are consumable replacements. Plan element inspection against the 90-minute nominal heating time — a lengthening ramp is the practical indicator of element ageing.
The controller digest describes the 500-series and MyNabertherm app functions, AMS2750F instrumentation types and recorder options, but none of these are part of the base furnace. The control package, thermocouple type and any data recorder must be selected and ordered explicitly; the base delivery is the chamber and elements only.
Selection & Integration Q&A
Pick the 04/17 for 4-litre air-atmosphere work up to 1750 °C where no vacuum or pressure is needed. Choose the 01/17 D or 03/17 D when a sealed retort is required, and the 08/17 when 4 litres is too small; the 04/17 sits between them in chamber size.
A 1-phase branch circuit sized to the 3.40 connected load (unit to be confirmed on the nameplate), plus a 500-series controller or equivalent with over-temperature limit set below 1750 °C. Controller, thermocouple and recorder are not in the base delivery and must be ordered separately.
MoSi₂ heating elements are consumable and age with service; a lengthening heat-up beyond the nominal 90 minutes signals replacement. Controllers, thermocouples, recorders and the MyNabertherm app link are separate order items, not included with the chamber.