Nabertherm LHTCT 01/16
Nabertherm ·Made in Germany · In Active Production

Nabertherm LHTCT 01/16

Nabertherm LHTCT 01/16 — Dental sintering furnaces.

The LHTCT 01/16 is a 1.5-litre dental sintering furnace with a 110 × 120 × 120 mm chamber, rated to 1550 °C and a 30 kg maximum load. Its 3.5 kW single-phase connection and 30 °C/min heating rate up to 1000 °C distinguish it from the larger LHTCT 03/16 sibling. It is intended for chairside or laboratory sintering of zirconia restorations.

Nabertherm LHTCT Series — Model Comparison & Selection

Model Chamber volume, LElectrical connectionMaximum load, kgWeight, kgMax temperature, °C
LHTCT 01/16 Current 1.51-phase30201550
LHTCT 03/16 33-phase360381550

Full specifications

Core Performance & Functional Specifications
Chamber volume 1.5 l
Chamber volume 1.5 l
Electrical connection 1-phase
Electrical connection 1-phase
Maximum load 30 kg
Connectedload4 mfr 3.5
Max. heating rate up to 1000 °C mfr 30
Inner dimensions (W × D × H) mfr 110 × 120 × 120 mm
Outer dimensions (W × D × H) mfr 340 × 335 mm
Connected mfr 3.5
Heating time mfr 30 min
Dimensions, Weight & Mechanical Design
Weight 20 kg
Weight 20 kg
Operating Conditions, Environment & Protection
Max temperature 1550 °C
Max temperature 1550 °C

Description

Construction and series positioning

Thermal behaviour

Electrical and control

Integration & Operating Notes

Electrical
Verify single-phase supply capacity for 3.5 kW connected load

The furnace draws a 3.5 kW connected load on a 1-phase supply. The branch circuit, protective device and supply conductors must be sized for this load before installation; the verified facts do not state the operating voltage or current, so the nameplate and wiring diagram of the actual unit must be consulted.

Factory Specification Sheet
Process Limits
Keep total batch mass at or below 30 kg

The maximum load is 30 kg. Exceeding it risks damage to the chamber and invalid sintering results. Because the chamber is only 1.5 l, the 30 kg limit is unlikely to be reached with dental frameworks, but it must be respected if the furnace is used for denser loads.

Factory Specification Sheet
Process Limits
Respect 30 °C/min heating limit below 1000 °C

The maximum heating rate up to 1000 °C is 30 °C/min. Programmed ramps that exceed this rate in the lower temperature range will not be followed by the furnace and may cause the actual profile to deviate from the set curve, affecting sintering results.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the LHTCT 01/16 instead of the LHTCT 03/16?

Pick the 01/16 for single-batch dental sintering where bench space is limited: 1.5 l chamber, 340 × 335 mm footprint, 20 kg. The LHTCT 03/16 has a larger chamber for higher throughput; choose it when batch size, not space, is the constraint.

What supply and circuit requirements must be met before connecting the LHTCT 01/16?

The furnace is a 1-phase unit with 3.5 kW connected load. The branch circuit and protective device must be sized for this load. The verified facts do not state voltage or current, so the unit nameplate and wiring diagram must be used for conductor and breaker sizing.

What maintenance and accessories are defined for this model in the supplied documents?

The verified facts contain no maintenance schedule, service intervals, or accessory list for the LHTCT 01/16. The attached controller and dental brochures do not specify consumables or cables for this model; these must be obtained from the unit's operating manual.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF