Nabertherm N 41/H
Nabertherm ·Made in Germany · In Active Production

Nabertherm N 41/H

Nabertherm N 41/H — Prozesse Unter Luft.

The N 41/H is a 40-litre electrically heated chamber furnace with a 1280 °C maximum temperature, built for process atmospheres under air. Its 350 × 500 × 250 mm chamber and 3-phase connection place it as the mid-size high-temperature unit in the N series, between the smaller N 81 variants and the larger N 87/H.

Nabertherm Chamber Furnaces electrically heated | Nabertherm Series — Model Comparison & Selection

Model Chamber volume, LMax temperature, °CWeight, kgElectrical connection
N 41/H Current 4012802603-phase
N 81 8012009503-phase
N 81/13 8013009703-phase

Full specifications

Core Performance & Functional Specifications
Chamber volume 40 l
Chamber volume 40 l
Chamber volume 40 l
Chamber volume 40 l
Chamber volume 40 l
Chamber volume 41 l
Electrical connection 3-phase
Electrical connection 3-phase
Electrical connection 3-phase
Electrical connection 3-phase
Electrical connection 3-phase
Electrical connection 3-phase
Heating mfr 15.0
Inner dimensions (W × D × H) mfr 350 × 500 × 250 mm
Outer dimensions (W × D × H) mfr 1040 × 1250 × 1340 mm
Connected mfr 15.0
Heating time mfr 105 min
Dimensions, Weight & Mechanical Design
Weight 260 kg
Weight 260 kg
Weight 260 kg
Weight 260 kg
Weight 260 kg
Weight 260 kg
Operating Conditions, Environment & Protection
Max temperature 1280 °C
Max temperature 1280 °C
Max temperature 1280 °C
Max temperature 1280 °C
Max temperature 1280 °C
Max temperature 1280 °C

Description

Construction and series positioning

The N 41/H is a chamber furnace from Nabertherm's electrically heated N series, with a 40 l working volume and a 1280 °C ceiling. Inner chamber dimensions are 350 mm wide × 500 mm deep × 250 mm high; the outer envelope is 1040 × 1180 × 1340 mm and the unit weighs 260 kg. Within the series it sits above the N 81 and N 81/13 in chamber volume and below the N 87/H, so it is the choice when the workload exceeds the small N 81 chamber but does not require the N 87/H envelope. The 3-phase electrical connection and 15.0 heating value are the only electrical data supplied; no voltage or current rating is stated for this model.

Thermal behaviour

No digitized heating or cooling curves are available for this model, so no heat-up rate, uniformity figure or recovery time can be quoted. The only thermal limit is the 1280 °C maximum temperature; operation must be planned so that setpoints and any load-related overshoot stay below it. The category path (Prozesse Unter Luft) indicates air-atmosphere process operation; no controlled-atmosphere or vacuum capability is documented for this model.

Control and documentation

None of the attached document digests (process controller series 500/MyNabertherm, fiber-optics catalog, foundry overview, dental brochure) contains model-specific sections, wiring data or ordering codes for the N 41/H. Controller functions, recorder options and AMS2750F instrumentation types are described only generically in the controller digest and cannot be assigned to this furnace without the model-specific manual. Installation, connection and operating specifics for the N 41/H must therefore be taken from its own instruction manual, which is not among the supplied digests.

Integration & Operating Notes

Electrical
Three-phase supply required; voltage and current not specified

The only electrical fact for this model is a 3-phase connection. No voltage, frequency, current or connected load is given, so the site supply and protection devices cannot be sized from this card; obtain the nameplate or model-specific wiring diagram before ordering the feed.

Factory Specification Sheet
Process Limits
Keep all setpoints and load overshoot below 1280 °C

The 1280 °C maximum temperature is the only documented thermal limit. Because no uniformity or overshoot data are supplied for this model, the control setpoint and any exothermic or load-related excursion must be planned with margin below this ceiling to avoid exceeding the chamber rating.

Factory Specification Sheet
Control & I/O
Controller and recorder configuration must be confirmed per order

The controller digest describes series 500 functions, MyNabertherm app connectivity, process data storage and AMS2750F instrumentation types only in general terms and prints no furnace model codes. The actual controller, interface and recorder fitted to an N 41/H must be taken from the order confirmation, not from this card.

Prozesssteuerung englisch (controller digest

Selection & Integration Q&A

When should I choose the N 41/H rather than the N 81, N 81/13 or N 87/H?

Pick the N 41/H when the workload needs more than the N 81/N 81/13 chamber but the N 87/H envelope is unnecessary: it offers 40 l and 1280 °C in a 350 × 500 × 250 mm chamber. The siblings' capacities and temperatures are not stated in the supplied facts, so compare them against their own data sheets before deciding.

What supply and protection does the 3-phase connection require?

Only the 3-phase connection type is documented; voltage, frequency, current and connected load are not given for this model. Size the feed, breaker and cable from the unit's nameplate or model-specific wiring diagram, not from this card, and confirm phase rotation and earthing per that diagram.

What maintenance schedule and accessories are defined for the N 41/H?

No maintenance intervals, service actions, error codes or included accessories are documented in the supplied facts or the attached digests for this model. Controller options, recorders and interface cables described generically in the controller digest are not confirmed as part of base delivery; verify the scope of supply on the order confirmation.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF