Nabertherm N 81/13
Nabertherm ·Made in Germany · In Active Production

Nabertherm N 81/13

Nabertherm N 81/13 — Prozesse Unter Luft.

The N 81/13 is a 3-phase electrically heated chamber furnace with an 80 l working volume (500 × 750 × 250 mm) and a maximum temperature of 1300 °C. Within the N-series it is the 80-litre, 1300 °C modification, distinguished from the N 81 and the higher-temperature N 41/H and N 87/H siblings. It serves as a batch heat-treatment unit for processes under air.

Nabertherm Chamber Furnaces electrically heated | Nabertherm Series — Model Comparison & Selection

Model Chamber volume, LMax temperature, °CWeight, kgElectrical connection
N 81/13 Current 8013009703-phase
N 41/H 4012802603-phase
N 81 8012009503-phase

Full specifications

Core Performance & Functional Specifications
Chamber volume 80 l
Chamber volume 80 l
Chamber volume 80 l
Chamber volume 80 l
Electrical connection 3-phase
Electrical connection 3-phase
Electrical connection 3-phase
Electrical connection 3-phase
Heating mfr 22.0
Inner dimensions (W × D × H) mfr 500 × 750 × 250 mm
Outer dimensions (W × D × H) mfr 1300 × 2000 × 2000 mm
Dimensions, Weight & Mechanical Design
Weight 970 kg
Weight 970 kg
Weight 970 kg
Weight 970 kg
Operating Conditions, Environment & Protection
Max temperature 1300 °C
Max temperature 1300 °C
Max temperature 1300 °C
Max temperature 1300 °C

Description

Construction and series positioning

Thermal behaviour

Control and documentation

Integration & Operating Notes

Control & I/O
Controller and recorder fitment is not fixed by the model code

The controller documentation describes 500-series controllers, MyNabertherm app connectivity, process-data storage and AMS2750F instrumentation types, but does not tie any of these to the N 81/13. Confirm the actual controller, interface and recorder configuration against the order before designing data acquisition around it.

Prozesssteuerung englisch

Selection & Integration Q&A

When should I choose the N 81/13 rather than the N 81 or the N 41/H and N 87/H siblings?

Pick the N 81/13 when you need the 80 l chamber at up to 1300 °C. The N 81 is the same 80-litre size without the /13 temperature class; the N 41/H and N 87/H are the other series variants. Compare their chamber volumes and temperature classes against your charge size and process temperature before deciding.

What supply and connection requirements must the site meet for this furnace?

The furnace is a 3-phase unit, but the verified data give no voltage, current or connected load. Size the supply, breaker and cable from the nameplate and order-specific connection diagram, and provide a 3-phase circuit rather than adapting a single-phase feed.

What installation environment and duty limits apply to the N 81/13?

Allow for a 970 kg floor load on a 1300 × 2000 mm footprint and 2000 mm height, on a level load-bearing floor with clearance for loading and control access. Keep setpoints at or below 1300 °C and arrange loads within the 500 × 750 × 250 mm chamber; no other duty-cycle limits are documented.

What is supplied with the furnace and what must be ordered or planned separately?

The verified facts list only the furnace itself: no controller model, recorder, thermocouples, cables or data interface are confirmed as included. The controller documentation covers 500-series units and the MyNabertherm app as options, so specify controller, instrumentation and any recorder explicitly on the order.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF