The N 61/H is a 3-phase chamber furnace with a 61-litre chamber (350 × 750 × 250 mm W×D×H) rated to 1280 °C, positioned between the smaller N 41/H and N 7/H in the series. Its 20 kW connected load and 105-minute heating time suit annealing, hardening and brazing processes requiring uniform temperature in a long, shallow workspace.

Nabertherm Chamber Furnaces for Annealing, Hardening and Brazing up to 1280 °C | Nabertherm Series — Model Comparison & Selection

Model Chamber volume, LElectrical connectionWeight, kgMax temperature, °C
N 61/H Current 613-phase4001280
N 7/H 91-phase601280

Full specifications

Core Performance & Functional Specifications
Chamber volume 61 l
Electrical connection 3-phase
Connected mfr 20.0
Heating time mfr 105 min
Inner dimensions (W × D × H) mfr 350 × 750 × 250 mm
Outer dimensions (W × D × H) mfr 1040 × 1430 × 1340 mm
Dimensions, Weight & Mechanical Design
Weight 400 kg
Operating Conditions, Environment & Protection
Max temperature 1280 °C

Description

Construction and series positioning

Thermal behaviour

Control and documentation

Integration & Operating Notes

Electrical
Confirm 3-phase supply capacity for 20 kW connected load

The furnace draws a 20 kW connected load on a 3-phase supply; the site distribution, cable cross-section and protective device must be sized for this load before installation, and the actual voltage/frequency must be confirmed against the nameplate because the verified facts do not state them.

Factory Specification Sheet
Process Limits
Do not exceed 1280 °C chamber temperature

The 1280 °C maximum is the upper process limit for annealing, hardening and brazing; operating above it risks heater and insulation damage, and the actual charge temperature should be verified by the controller rather than inferred from the setpoint.

Factory Specification Sheet
Control & I/O
Controller and recorder options are not fixed by the model code

The controller digest describes 500-series controllers, MyNabertherm app connectivity, process-data storage and AMS2750F instrumentation types, but does not assign a specific controller to the N 61/H; the controller, thermocouple type and any recorder must therefore be specified separately at order.

Prozesssteuerung englisch

Selection & Integration Q&A

When should I choose the N 61/H rather than the N 41/H or N 7/H?

Pick the N 61/H when the 61-litre, 350 × 750 × 250 mm chamber fits long or tray-loaded batches at up to 1280 °C. The N 41/H and N 7/H are smaller siblings; choose them only if their smaller chambers suit the workload, since the N 61/H's 20 kW 3-phase load is the trade-off for capacity.

What supply and protective equipment does the 3-phase 20 kW connection require?

The furnace is a 3-phase unit with 20 kW connected load; the site must provide a 3-phase feed sized for that load with matching cable cross-section and protective device. The verified facts do not state voltage or frequency, so confirm the nameplate rating before ordering switchgear.

What is supplied with the base furnace and what must be ordered separately?

The verified facts list only the furnace itself; no controller, thermocouple, recorder or process-data software is confirmed as included. The controller digest covers 500-series controllers and MyNabertherm app options, so specify controller, instrumentation type and any recorder explicitly at order.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF