Nabertherm NR(A) 40/..
Nabertherm NR(A) 40/.. — Hot Wall Retort Furnaces.
The NR(A) 40/.. is a hot-wall retort furnace with a 40-litre useful volume and a work space of 325 × 400 × 325 mm, positioned as the smallest chamber in the NR(A) series alongside the 100-, 160- and 1000-litre siblings. Its hot-wall retort construction is intended for processes requiring a defined, indirectly heated retort atmosphere up to the series limit of 1100 °C. The model code denotes chamber volume, not an electrical rating.
Nabertherm NR(A) Series — Model Comparison & Selection
| Model |
|---|
| NR(A) 40/.. Current |
| NR(A) 160/.. |
Full specifications
| Work space dimensions in mm mfr | 325 |
| Useful volume mfr | 40 |
| Connected1 mfr | 34 |
| Outer dimensions (W × D × H) mfr | 12002 × 1600 × 1900 mm |
Description
Construction and series positioning
- Hot-wall retort furnace: the retort is heated from the outside by the wall-mounted heating system, giving a defined process chamber without direct heater exposure.
- Useful volume 40 litres; work space 325 × 400 × 325 mm (W × D × H).
- Smallest member of the NR(A) series listed here; the NR(A) 100/.., NR(A) 160/.. and NR(A) 1000/.. offer larger chambers for higher batch masses.
- Outer dimensions are stated in the factory data as 12002 × 1600 × 1900 mm; this value is internally inconsistent with a 40-litre chamber and is therefore not used for layout planning.
Thermal behaviour and media
- Series maximum temperature is 1100 °C; no model-specific heating curve or uniformity data is available for this size.
- No digitized curve points, matched performance specs or process-media specifications were supplied for this model, so heat-up rate, atmosphere compatibility and retort pressure ratings cannot be stated.
- The hot-wall principle separates the heating elements from the retort interior; the process atmosphere is confined by the retort, but the permissible gas or vacuum conditions must be confirmed against the series documentation before use.
Control, installation and operation
- The attached controller documentation covers the Nabertherm 500-series controllers and the MyNabertherm app, including process-data storage and AMS2750F instrumentation types; it does not define a model-specific control configuration for the NR(A) 40/..
- No electrical connection data (voltage, power, phase) is available for this model; the 'Connected1' value of 34 in the factory data carries no unit and is not used.
- Installation clearances, floor loading and exhaust requirements are not documented in the supplied digests and must be taken from the model-specific operating manual.
Integration & Operating Notes
The 1100 °C figure is the series maximum; operating the retort above it risks heater, insulation and retort damage. Because no model-specific over-temperature limit is published for the 40-litre chamber, the controller's limit function should be set from the model operating manual, not from the series headline value alone.
The controller digest describes 500-series controllers and the MyNabertherm app, including process-data recording and AMS2750F instrumentation types, but prints no furnace model codes. The actual controller fitted to an NR(A) 40/.. and its interface set must be confirmed on the order configuration.
No voltage, phase or connected-load value for the NR(A) 40/.. appears in the verified facts; the factory 'Connected1' entry of 34 has no unit and cannot be interpreted. Size the supply and protection from the nameplate of the delivered unit.
The stated outer dimensions of 12002 × 1600 × 1900 mm are inconsistent with a 40-litre work space and are treated as a data error. Obtain the general arrangement drawing for the NR(A) 40/.. before fixing floor space, door swing and service access.
Selection & Integration Q&A
Pick the 40/.. when the batch fits the 325 × 400 × 325 mm work space and 40-litre useful volume, keeping the heated volume and connected load as small as possible. Move to the 100/.. or 160/.. when larger parts or higher throughput per cycle are required; all share the 1100 °C series ceiling.
Confirm the fitted controller from the 500-series/MyNabertherm options and whether AMS2750F instrumentation is required, since the controller document defines no model-specific fit. Electrical supply data is absent from the verified facts, so the nameplate of the delivered unit governs cable and protection sizing.
The supplied documents give no clearance, floor-loading or duty-cycle figures for the NR(A) 40/.., and the listed outer dimensions are inconsistent with the 40-litre chamber. Installation clearances and permissible continuous operation must be taken from the model operating manual and arrangement drawing.
No maintenance schedule, spare-parts list or scope-of-delivery breakdown for the NR(A) 40/.. is included in the verified facts. Retort, thermocouples, controller options, recording software and exhaust accessories should be clarified against the order documents rather than assumed as standard.