Shimadzu Hits X Series
Shimadzu ·Made in Japan · In Active Production

Shimadzu Hits X Series

Shimadzu Hits X Series — Testing machines.

The Shimadzu Trapezium HITS X Series is a software-centric high-speed impact testing system comprising testing and data-processing software running on a Windows PC with an NI PCI-6132 or ADM670 AD expansion board. It acquires sensor data via RS232C from an optional 4870-type controller and supports up to three puncture and three tensile sensors with selectable filter frequencies. It is used to control impact tests, capture load-stroke-time curves, and produce statistical reports.

Full specifications

Description

System architecture and positioning

Measurement behavior and sensor handling

Installation, control, and operation

Integration & Operating Notes

Electrical
PC must provide a free full-size PCI slot and RS232C port

The AD expansion board (NI PCI-6132 or ADM670) requires a full-size PCI slot, and the controller connects via RS232C. Without these, the system cannot acquire data or communicate; plan the PC configuration accordingly before installation.

Instruction Manual, Section 2.1, p.22
Control & I/O
Sensor changes force a return to System Setting before testing

The software compares sensor information at startup and before each test. If a sensor has been changed, the Testing screen is blocked and the System Setting screen is displayed, ensuring the correct sensor ID and calibration are active.

Instruction Manual, Section 3.2.1, p.37
Maintenance
Back up configuration files to external media regularly

Files HTM_System.fil, HTM.ini, and HTMTable.ini contain calibration and system settings. Backing them up to CD-R or other media allows recovery after PC failure or software re-installation, avoiding recalibration downtime.

Instruction Manual, Section 2.2.1, p.25
Maintenance
Replace sensors only after exiting software or returning Home

Hot-swapping a sensor while the software is active can cause incorrect measurement values. Always exit the software or move to the Home screen, then replace the sensor and confirm the connection state on the System Setting screen.

Instruction Manual, Section 3.1.3, p.34

Selection & Integration Q&A

When should I choose this HITS X Series model instead of a sibling variant?

Choose this model when you need support for both NI PCI-6132 and ADM670 boards and optional 4870-type controller integration. Sibling variants may lack one board type or controller compatibility; verify against your existing PC and controller.

What are the requirements for the host PC and adjacent controller?

The PC needs Windows 7/10, 1 GHz CPU, 256 MB RAM, 8 GB HDD, 1920×1200 display, a free full-size PCI slot, and an RS232C port. The controller connects via RS232C; a 4870-type controller is needed for external trigger.

What maintenance and accessories are required beyond the base delivery?

The base delivery includes software and manuals; you must provide a compliant PC, AD board, and cables. Regularly back up configuration files (HTM_System.fil, HTM.ini, HTMTable.ini) to external media. Sensor replacement requires exiting software first.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Trapezium HITS Instruction Manual
Manual ·5,4 МБ ·134 pp.
View PDF