Shimadzu MOC-120H

Shimadzu MOC-120H — Moisture meters.

The Shimadzu Moc 120H is an infrared heat drying moisture analyzer using a mid-wave quartz heater and a 120 g capacity balance with 0.001 g resolution. It determines moisture content from 0.01% to 100.00% with 0.01% display, offering automatic or timed halting and rapid, slow, or step drying modes. This model suits benchtop quality control where samples up to 120 g require precise, reproducible loss-on-drying measurements.

Full specifications

Core Performance & Functional Specifications
Resolution Large backlit LCD
Drying modes 9 combinations of drying and halting modes
Heat source Mid-wave infrared quartz heater
Model MOC-120H (321-63300-10)
Temperature settings (Sample position temperature)
Stored procedures 10
Measurement principle (Texture Analyzer EZ-SX) mfr high-precision load cell (Texture Analyzer EZ-SX)
Sample amount (Mayonnaise, Moisture Analyzer) mfr 1 g (Mayonnaise, Moisture Analyzer)
Measurement time (Mayonnaise, Moisture Analyzer) mfr 10:00 min (Mayonnaise, Moisture Analyzer)
Moisture ratio (Mayonnaise, Moisture Analyzer) mfr 20.61 % (Mayonnaise, Moisture Analyzer)
Repeatability (Mayonnaise, Moisture Analyzer) mfr 0.46 % (Mayonnaise, Moisture Analyzer)
Sample amount (Instant coffee, Moisture Analyzer) mfr 1 g (Instant coffee, Moisture Analyzer)
Measurement time (Instant coffee, Moisture Analyzer) mfr 10:00 min (Instant coffee, Moisture Analyzer)
Moisture ratio (Instant coffee, Moisture Analyzer) mfr 7.43 % (Instant coffee, Moisture Analyzer)
Repeatability (Instant coffee, Moisture Analyzer) mfr 1.18 % (Instant coffee, Moisture Analyzer)
Sample amount (Chocolate, Moisture Analyzer) mfr 3 g (Chocolate, Moisture Analyzer)
Measurement time (Chocolate, Moisture Analyzer) mfr 6:18 min (Chocolate, Moisture Analyzer)
Moisture ratio (Chocolate, Moisture Analyzer) mfr 2.36 % (Chocolate, Moisture Analyzer)
Repeatability (Chocolate, Moisture Analyzer) mfr 1.49 % (Chocolate, Moisture Analyzer)
Sample amount (Corn starch, Moisture Analyzer) mfr 5 g (Corn starch, Moisture Analyzer)
Measurement time (Corn starch, Moisture Analyzer) mfr 7:54 min (Corn starch, Moisture Analyzer)
Moisture ratio (Corn starch, Moisture Analyzer) mfr 12.94 % (Corn starch, Moisture Analyzer)
Repeatability (Corn starch, Moisture Analyzer) mfr 0.16 % (Corn starch, Moisture Analyzer)
Sample amount (White rice, Moisture Analyzer) mfr 5 g (White rice, Moisture Analyzer)
Measurement time (White rice, Moisture Analyzer) mfr 12:30 min (White rice, Moisture Analyzer)
Moisture ratio (White rice, Moisture Analyzer) mfr 15.12 % (White rice, Moisture Analyzer)
Heater operational life (mid-wave infrared quartz heater) mfr 20,000 to 30,000 hours (mid-wave infrared quartz heater)
Ending modes mfr Automatic ending mode; Timed ending mode
Alternate drying modes mfr Rapid drying mode; Slow drying mode
Weighing sensor mfr Shimadzu UniBloc cell
Electrical, Power & Drive Specifications
Power requirements mfr AC 100 to 120 / 220 to 240 V
Power consumption mfr 640 W maxi
Interfaces, Connections & Control
Data interface RS-232C (WindowsDirect)

Description

Construction and positioning

Integration & Operating Notes

Electrical
Verify supply voltage before connection

The unit accepts either 100–127 V AC or 220–240 V AC, but the specific configuration must be confirmed against the nameplate. Connecting a 100–127 V unit to a 220–240 V supply will damage the instrument. Maximum power draw is 640 W, so ensure the circuit can supply this continuously.

Factory Specification Sheet
Process Limits
Keep ambient within 5–40 °C and ≤85% RH

Operation outside this range may affect balance stability and moisture results. Condensation at high humidity can corrupt readings; allow the instrument to equilibrate if moved from a cold environment. The 85% RH maximum is a non-condensing limit.

Factory Specification Sheet
Mounting
Place on a stable, level surface away from drafts

The windbreak case is supplied to shield the sample from air currents. Install the pan stop and windbreak as per the instruction manual. Avoid vibration and direct sunlight, which can affect the 0.001 g resolution balance.

Standard accessories list

Selection & Integration Q&A

What are the power and environmental requirements for integrating the Moc 120H into a laboratory bench?

It requires 100–127 V or 220–240 V AC, 640 W max, and operates in 5–40 °C, ≤85% RH. Ensure the supply matches the unit's configuration and that the bench is stable and draft-free.

What mounting and duty-cycle limits apply to the Moc 120H?

Mount on a level, vibration-free surface away from drafts. Ambient must be 5–40 °C and ≤85% RH. No duty-cycle limit is specified, but continuous high-temperature operation may require cooling periods; refer to the manual.