Shimadzu Nexera UC Prep
Shimadzu ·Made in Japan · In Active Production

Shimadzu Nexera UC Prep

Shimadzu Nexera UC Prep — Chromatographs.

The Shimadzu Nexera UC Prep is a preparative supercritical fluid chromatography (SFC) system configured for purification-scale separations. It extends the analytical Nexera UC platform to milligram-to-gram throughput by integrating a preparative pump, injection valve, and fraction collector. Its primary purpose is isolating target compounds from complex matrices with CO2-based mobile phases, reducing organic solvent consumption versus conventional preparative HPLC.

Direct drop-in replacements

0%
match
⚖️ Compare
0%
match
⚖️ Compare

Full specifications

Core Performance & Functional Specifications
Maximum operating pressure (UHPLC/SFC switching system) mfr 66 MPa (UHPLC/SFC switching system)
Number of switchable columns (chiral screening system) mfr up to 12 columns (chiral screening system)
Number of switchable modifiers (chiral screening system) mfr 7 types (chiral screening system)
Fractionation scale (2.0 mm I.D. column) mfr 5 mg (2.0 mm I.D. column)
Fractionation scale (4.6 mm I.D. column) mfr 100 mg (4.6 mm I.D. column)
Fractionation scale (10 mm I.D. column) mfr 500 mg (10 mm I.D. column)
Fractionation scale (20 mm I.D. column) mfr 1 g (20 mm I.D. column)
Flow rate (4.6 mm I.D. column, Shim-pack UC-PBr 4.6 x 250 mm) mfr 3.0 mL/min (4.6 mm I.D. column, Shim-pack UC-PBr 4.6 x 250 mm)
Flow rate (20 mm I.D. column, Shim-pack UC-PBr 20 x 250 mm) mfr 56.7 mL/min (20 mm I.D. column, Shim-pack UC-PBr 20 x 250 mm)
Injection volume (4.6 mm I.D. column) mfr 20 μL (4.6 mm I.D. column)
Injection volume (20 mm I.D. column) mfr 500 μL (20 mm I.D. column)
Fraction volume (4.6 mm I.D. column) mfr 10 mg (4.6 mm I.D. column)
Fraction volume (20 mm I.D. column) mfr 250 mg (20 mm I.D. column)
Typical sample preparation time (on-line SFE-SFC) mfr 60 minutes (on-line SFE-SFC)
System (Recovery rate test) mfr Nexera UC Prep Stacked fraction system (Recovery rate test)
Flow rate (Recovery rate test) mfr 125 mL/min (Recovery rate test)
Detection wavelength (Caffeine, recovery rate test) mfr 272 nm (Caffeine, recovery rate test)
BPR pressure (Recovery rate test) mfr 10 MPa (Recovery rate test)
Sample concentration (Caffeine, recovery rate test) mfr 10 mg/mL (Caffeine, recovery rate test)
Injection volume (Recovery rate test) mfr 1 mL (Recovery rate test)
Modifier (LotusStream separator test) mfr Methanol (LotusStream separator test)
Modifier concentration (LotusStream separator test) mfr 20 % (LotusStream separator test)
Modifier flow rate (LotusStream separator test) mfr 100 mL/min (LotusStream separator test)
System (Contamination test) mfr Nexera UC Prep Multi-fraction system (Contamination test)
Makeup (Contamination test) mfr Methanol (Contamination test)
Makeup flow rate (Contamination test) mfr 15 mL/min (Contamination test)
BPR pressure (Contamination test) mfr 10 MPa (Contamination test)
Sample (Contamination test) mfr Linalool 1 % (Contamination test)
Fraction collector (Contamination test) mfr FRC-40 SF (Contamination test)
Column (Carryover test) mfr Silica column (250 mm L. × 20 mm I.D.) (Carryover test)
Makeup flow rate (Carryover test) mfr 10 mL/min (Carryover test)
Sample concentration (Hydrocortisone, carryover test) mfr 30 mg/mL (Hydrocortisone, carryover test)
Modifier (Carryover test) mfr Methanol (Carryover test)
Flow rate (Carryover test) mfr 3 mL/min (Carryover test)
Allowable maximum pressure (LC-40D) mfr 44 MPa (LC-40D)
Allowable maximum pressure (LC-40D XR) mfr 70 MPa (LC-40D XR)
Allowable maximum pressure (LC-40D XS) mfr 105 MPa (LC-40D XS)
Allowable maximum pressure (LC-40D X3) mfr 130 MPa (LC-40D X3)
Flow rate settings range (LC-40D, 1.0 to 44 MPa) mfr 0.0001 to 5.0000 mL/min (LC-40D, 1.0 to 44 MPa)
Flow rate settings range (LC-40D, 1.0 to 22 MPa) mfr 5.0001 to 10.0000 mL/min (LC-40D, 1.0 to 22 MPa)
Flow rate accuracy (under specified conditions) mfr ≤ ± 1% or ± 2 μL/min, whichever greater (under specified conditions)
Flow rate precision mfr ≤ 0.06% RSD or 0.02 minSD, whichever greater
Gradient range of set concentrations (0.1% step) mfr 0 to 100 % (0.1% step)
Gradient concentration accuracy (under specified conditions) mfr ± 0.5 % (under specified conditions)
Dimensions (LC-40D) mfr W 260 × D 500 × H 140 mm (LC-40D)
Plunger capacity (LC-20AR) mfr 47 μL (LC-20AR)
Flow rate setting range (LC-20AR, 1.0 to 50 MPa) mfr 0.001 to 5 mL/min (LC-20AR, 1.0 to 50 MPa)
Flow rate setting range (LC-20AR, 1.0 to 25 MPa) mfr 5.001 to 20 mL/min (LC-20AR, 1.0 to 25 MPa)
Flow rate accuracy (LC-20AR, 0.1 to 5.0 mL/min) mfr No more than ±1% or ±10 μL/min, whichever is gre (LC-20AR, 0.1 to 5.0 mL/min)
Flow rate precision (LC-20AR) mfr No more than 0.08% RSD or 0.02 min SD, whichever (LC-20AR)
Number of degassed solvents (DGU-403) mfr 3 (DGU-403)
Degassed flow line capacity (DGU-403) mfr 400 μL/1 line (DGU-403)
Injection volume accuracy (SIL-40C XR, 5 μL injection, n = 20) mfr ≤ ± 1 % (SIL-40C XR, 5 μL injection, n = 20)
Wavelength range (SPD-40) mfr 190 to 700 nm (SPD-40)
Dimensions, Weight & Mechanical Design
Column inner diameter mfr 4.6 mm I.D. (Nexera UC)
Column inner diameter mfr 30 mm I.D. (Nexera UC Prep)
Weight (LC-40D) mfr 10 kg (LC-40D)
Weight (LC-40D XR) mfr 12 kg (LC-40D XR)
Electrical, Power & Drive Specifications
Power supply (LC-40D series) mfr 100 to 240 V AC, 150 VA, 50/60 Hz (LC-40D series)
Materials, Media & Process Compatibility
Available pH range mfr 1 to 14

Description

Construction and Series Positioning

The Nexera UC Prep is the preparative-scale member of Shimadzu's Nexera UC supercritical fluid chromatography family. While analytical Nexera UC systems prioritize resolution and detection sensitivity at microliter flow rates, the UC Prep modification substitutes a higher-capacity pumping module, a larger-volume injection loop, and a fraction collection stage to handle elevated mass loads. The architecture retains the CO2 delivery and back-pressure regulation scheme common to the series but scales column dimensions and flow-path components accordingly. ### Behavior Under Load and Across Media

Supercritical CO2 serves as the primary mobile phase, with an organic co-solvent (typically methanol or ethanol) added via a secondary pump to modulate polarity. Because the mobile phase is compressible, system pressure must be actively regulated at the back-pressure regulator to maintain a stable supercritical state throughout the column and into the detector. At preparative scale, the ratio of co-solvent to CO2 and the total flow rate determine both retention and the recovery window for fraction collection; these parameters are method-specific and must be established empirically for each target-compound/matrix pair. ### Installation, Connection, and Control

Installation requires a CO2 supply with adequate pressure and purity, an exhaust/vent path for depressurized gas, and a solvent reservoir for the co-solvent pump. The system is controlled through Shimadzu's chromatography data system, which coordinates injection, gradient delivery, back-pressure regulation, and fraction-valve switching. Fraction collection timing is triggered by time-based or signal-threshold events programmed in the method; the collector must be configured with the appropriate tube or plate format before a run.

Integration & Operating Notes

Maintenance
Back-pressure regulator and seals require periodic inspection

The back-pressure regulator and pump seals are wear items exposed to pressurized CO2 and co-solvent. The manual specifies periodic inspection and replacement intervals; neglecting these can lead to pressure drift, seal leakage, and inconsistent retention times. Keep spare seal kits and regulator components on hand, and log pressure stability as an early indicator of wear.

Nexera UC Prep Instruction Manual, Maintenance Schedule
Mounting
Bench space and ventilation must accommodate CO2 venting

The system requires a stable laboratory bench with sufficient clearance for the preparative pump, column oven, detector, and fraction collector, plus a vent path for depressurized CO2. Because CO2 is heavier than air, the installation area should be ventilated at low level to prevent accumulation; confirm room ventilation meets the manual's requirements before commissioning.

Nexera UC Prep Instruction Manual, Site Preparation

Selection & Integration Q&A

When should I choose the Nexera UC Prep over an analytical Nexera UC system?

Choose the UC Prep when the goal is isolating milligram-to-gram quantities of target compounds and fraction collection is required. Analytical Nexera UC systems are optimized for resolution and detection at microliter flow rates and lack preparative-scale pumping and collection hardware.

What CO2 supply and co-solvent delivery requirements must be met for the UC Prep?

The system needs instrument-grade, moisture-free CO2 at sufficient inlet pressure to stay above the critical point, plus a co-solvent pump fed from a compatible solvent reservoir. Verify supply pressure and purity against the manual's installation requirements before commissioning.

What maintenance items and accessories are not included in the base delivery?

Base delivery typically excludes consumable pump seals, back-pressure regulator rebuild kits, fraction collection tubes or plates, and the CO2 supply regulator and plumbing. These must be ordered separately; consult the manual's maintenance schedule for replacement intervals.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
LC-40P SF Instruction Manual - Solvent Delivery Module
Manual ·5,2 МБ ·98 pp.
View PDF
PDF
c190-e288
Datasheet ·10,0 МБ ·20 pp.
View PDF
PDF
Evaluating the Performance of the LotusStream Gas-Liquid Separator for Preparative Supercritical Fluid Chromatography
Datasheet ·1,2 МБ ·4 pp.
View PDF
PDF
SFC-40P Instruction Manual - Back Pressure Regulator
Manual ·3,5 МБ ·68 pp.
View PDF
PDF
c190-e291
Datasheet ·596,5 КБ ·8 pp.
View PDF