Shimadzu Nexera X4
Shimadzu ·Made in Japan · In Active Production

Shimadzu Nexera X4

Shimadzu Nexera X4 — Chromatographs.

The Shimadzu Nexera X4 is a modular HPLC system controller that integrates and coordinates up to eight units—including solvent delivery, autosamplers, column ovens, and detectors—via Ethernet. It features a touch-panel LabSolutions Web monitor and a built-in reservoir tray, distinguishing it as the central control hub of the Nexera series. Its primary purpose is to orchestrate method execution, signal acquisition, and system communication in analytical chromatography workflows.

Direct drop-in replacements

71%
match
⚖️ Compare
⚖️ Compare
50%
match
⚖️ Compare

Full specifications

Core Performance & Functional Specifications
Flow rate binary gradient (LC-40B X4)
Column temperature 1 – 12 (Shim-pack NovaCore C18)
SCL-40 / CBM-40: 4 to 35 °C
Degassing online degassing (SSU-40)
Detector types photodiode array (SPD-M40 X4)
Number of degassed solvents 5 (SSU-40)
Plunger configuration mfr four independently actuated plungers (LC-40B X4)
Pressure feedback mechanism mfr yes (LC-40B X4)
Solvent switching capacity mfr up to 4 solutions per pump (SSU-40)
Flow cell mfr capillary cell (SPD-M40 X4)
Autosampler valve mfr high-pressure valve (SIL-40C X4)
Injection mode mfr low-dispersion (SIL-40C X4)
Needle rinsing mfr internal/external (SIL-40C X4)
Peak broadening reduction mfr 60% smaller (SIL-40C X4)
Column surface area mfr 200 m2/g (Shim-pack NovaCore C18)
Column carbon loading mfr 11 % (Shim-pack NovaCore C18)
Column pore size mfr 12 nm (Shim-pack NovaCore C18)
Column USP code mfr L1 (Shim-pack NovaCore C18)
Number of controllable units mfr 8 (SCL-40)
Number of controllable units mfr 8 (Using option: 12) (CBM-40)
Number of controllable units mfr 4 (excluding built-in solvent delivery unit) (CBM-40lite)
Event input/output mfr Input: 1, Output: 2 (SCL-40)
Analog signal input mfr Up to two channels (option) (SCL-40)
Analog signal input mfr One channel (option) (CBM-40)
Reservoir tray mfr Included as standard (SCL-40)
Pumping method mfr Micro-volume double plunger pump (LC-40B X4)
Allowable maximum pressure mfr 130 MPa (LC-40B X4)
Flow rate settings range (alt) mfr 0.0001 to 2.0000 mL/min (LC-40B X4)
Flow rate accuracy mfr ±1 % (at 1 mL/min, 80 MPa, with water, stable wi (LC-40B X4)
Gradient mode mfr Two-solvent high-pressure gradient (LC-40B X4)
Range of gradient mixing ratio mfr 0 to 100 % (0.1 % step) (LC-40B X4)
Number of selectable solvents mfr Up to 4 solvents per pump (maximum 2 pumps) (SSU-40)
Degassed flow line capacity mfr 400 μL/1 line (SSU-40)
Dimensions, Weight & Mechanical Design
Dimensions and weight mfr W260 × D500 × H140 mm, 6 kg (SCL-40)
Dimensions and weight mfr W260 × D500 × H72 mm, 5 kg (CBM-40)
Dimensions and weight mfr W260 × D500 × H210 mm (excluding protrusions), 2 (LC-40B X4)
Dimensions and weight mfr W260 × D500 × H72 mm, 5 kg (SSU-40)
Electrical, Power & Drive Specifications
Power supply mfr 100 to 240 V AC, 50 VA, 50/60 Hz (SCL-40 / CBM-40)
Power supply mfr 100 to 240 V AC, 50/60 Hz, 150 VA (LC-40B X4)
Interfaces, Connections & Control
Fitting sealing structure mfr end-surface sealing (Nexlock II)
Communication interface mfr Ethernet (SCL-40)
Materials, Media & Process Compatibility
Available pH range mfr 1 to 14 (LC-40B X4)

Description

Construction and Architecture

Integration & Operating Notes

Mounting
Place on stable bench or atop solvent delivery unit

The X4 is compact (260 mm × 140 mm) and includes a reservoir tray, so it is typically positioned near the solvent delivery unit. Ensure adequate clearance for the touch panel and cable connections. Avoid stacking heavy items on top.

Factory Specification Sheet
Electrical
Power can be drawn from solvent delivery unit

The X4 can be powered either directly from a 100–240 V AC supply (50 VA) or from the solvent delivery unit. Verify that the delivery unit's power output can supply the additional load; exceeding its capacity may cause shutdown or damage.

Factory Specification Sheet
Control & I/O
Event outputs can trigger external devices

With one event input and two outputs, the X4 can start external equipment or receive status signals. Configure the logic in LabSolutions to avoid conflicts, especially when integrating third-party devices that expect dry-contact closures.

Factory Specification Sheet
Process Limits
Maximum eight units, expandable to twelve

The system supports up to eight controllable units (four solvent delivery, one autosampler, four column ovens, two detectors). Exceeding this without the expansion option will prevent recognition of additional modules. Plan the configuration accordingly.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the Nexera X4 instead of a simpler controller or a different model in the Nexera series?

Choose the X4 when you need to control multiple units (up to 8, or 12 with option) including multiple solvent delivery units, ovens, and detectors. For single-unit or basic setups, a lower-tier controller may suffice, but the X4 offers expandability and integrated touch-panel monitoring.

What are the requirements for connecting the X4 to my existing HPLC modules and PC?

The X4 communicates via Ethernet to the PC and controls units through the system bus. Ensure all modules are compatible with LabSolutions and that the PC meets software requirements. Power can be supplied directly or from the solvent delivery unit; check the delivery unit's power budget.

What are the environmental and duty-cycle limitations for the X4?

The operating temperature range is specified as 35.0 °C (likely maximum). Install in a stable, indoor laboratory environment away from direct heat sources. Continuous duty is supported, but ensure adequate ventilation around the unit.

Dimensional Drawings & Technical Documentation

Dimensional drawings

performance curve

Click drawing to inspect vector dimensions

Technical documentation

PDF
c196-e102
Datasheet ·2,4 МБ ·12 pp.
View PDF
PDF
c196-e103
Datasheet ·740,0 КБ ·8 pp.
View PDF