Shimadzu Nexera X4
Shimadzu Nexera X4 — Chromatographs.
The Shimadzu Nexera X4 is a modular HPLC system controller that integrates and coordinates up to eight units—including solvent delivery, autosamplers, column ovens, and detectors—via Ethernet. It features a touch-panel LabSolutions Web monitor and a built-in reservoir tray, distinguishing it as the central control hub of the Nexera series. Its primary purpose is to orchestrate method execution, signal acquisition, and system communication in analytical chromatography workflows.
Direct drop-in replacements
Full specifications
| Flow rate | binary gradient (LC-40B X4) |
| Column temperature | 1 – 12 (Shim-pack NovaCore C18) SCL-40 / CBM-40: 4 to 35 °C |
| Degassing | online degassing (SSU-40) |
| Detector types | photodiode array (SPD-M40 X4) |
| Number of degassed solvents | 5 (SSU-40) |
| Plunger configuration mfr | four independently actuated plungers (LC-40B X4) |
| Pressure feedback mechanism mfr | yes (LC-40B X4) |
| Solvent switching capacity mfr | up to 4 solutions per pump (SSU-40) |
| Flow cell mfr | capillary cell (SPD-M40 X4) |
| Autosampler valve mfr | high-pressure valve (SIL-40C X4) |
| Injection mode mfr | low-dispersion (SIL-40C X4) |
| Needle rinsing mfr | internal/external (SIL-40C X4) |
| Peak broadening reduction mfr | 60% smaller (SIL-40C X4) |
| Column surface area mfr | 200 m2/g (Shim-pack NovaCore C18) |
| Column carbon loading mfr | 11 % (Shim-pack NovaCore C18) |
| Column pore size mfr | 12 nm (Shim-pack NovaCore C18) |
| Column USP code mfr | L1 (Shim-pack NovaCore C18) |
| Number of controllable units mfr | 8 (SCL-40) |
| Number of controllable units mfr | 8 (Using option: 12) (CBM-40) |
| Number of controllable units mfr | 4 (excluding built-in solvent delivery unit) (CBM-40lite) |
| Event input/output mfr | Input: 1, Output: 2 (SCL-40) |
| Analog signal input mfr | Up to two channels (option) (SCL-40) |
| Analog signal input mfr | One channel (option) (CBM-40) |
| Reservoir tray mfr | Included as standard (SCL-40) |
| Pumping method mfr | Micro-volume double plunger pump (LC-40B X4) |
| Allowable maximum pressure mfr | 130 MPa (LC-40B X4) |
| Flow rate settings range (alt) mfr | 0.0001 to 2.0000 mL/min (LC-40B X4) |
| Flow rate accuracy mfr | ±1 % (at 1 mL/min, 80 MPa, with water, stable wi (LC-40B X4) |
| Gradient mode mfr | Two-solvent high-pressure gradient (LC-40B X4) |
| Range of gradient mixing ratio mfr | 0 to 100 % (0.1 % step) (LC-40B X4) |
| Number of selectable solvents mfr | Up to 4 solvents per pump (maximum 2 pumps) (SSU-40) |
| Degassed flow line capacity mfr | 400 μL/1 line (SSU-40) |
| Dimensions and weight mfr | W260 × D500 × H140 mm, 6 kg (SCL-40) |
| Dimensions and weight mfr | W260 × D500 × H72 mm, 5 kg (CBM-40) |
| Dimensions and weight mfr | W260 × D500 × H210 mm (excluding protrusions), 2 (LC-40B X4) |
| Dimensions and weight mfr | W260 × D500 × H72 mm, 5 kg (SSU-40) |
| Power supply mfr | 100 to 240 V AC, 50 VA, 50/60 Hz (SCL-40 / CBM-40) |
| Power supply mfr | 100 to 240 V AC, 50/60 Hz, 150 VA (LC-40B X4) |
| Fitting sealing structure mfr | end-surface sealing (Nexlock II) |
| Communication interface mfr | Ethernet (SCL-40) |
| Available pH range mfr | 1 to 14 (LC-40B X4) |
Description
Construction and Architecture
- The Nexera X4 is a compact control module (260 mm W × 140 mm H) designed to sit atop or beside the solvent delivery unit, from which it can also draw power (100–240 V AC, 50 VA, 50/60 Hz). - It provides a central interface for up to eight controllable units (expandable to twelve with an option), including up to four solvent delivery units, one autosampler, four column ovens, and two detectors. - Standard features include a reservoir tray, Ethernet communication, and a touch-panel LabSolutions Web monitor for local status and control. ### Behavior and Control
- The system supports event input/output (1 input, 2 outputs) and optional analog signal input (up to two channels), enabling synchronization with external devices or legacy detectors. - Control logic is managed via LabSolutions software, which coordinates unit operations, method execution, and data acquisition. The X4 acts as the communication bridge between the PC and the modular units. ### Installation and Operation
- The X4 requires an Ethernet connection to the control PC and a power source either directly or via the solvent delivery unit. It is intended for indoor laboratory environments; the operating temperature range is specified as 35.0 °C (likely a maximum or nominal value, but only this single figure is provided). - Installation involves stacking or benchtop placement, with attention to cable routing and access to the touch panel. The reservoir tray accommodates solvent reservoirs for the delivery units. - No PDF documentation was provided, so specific installation, connection, and control details are limited to the factory specifications listed.
Integration & Operating Notes
The X4 is compact (260 mm × 140 mm) and includes a reservoir tray, so it is typically positioned near the solvent delivery unit. Ensure adequate clearance for the touch panel and cable connections. Avoid stacking heavy items on top.
The X4 can be powered either directly from a 100–240 V AC supply (50 VA) or from the solvent delivery unit. Verify that the delivery unit's power output can supply the additional load; exceeding its capacity may cause shutdown or damage.
With one event input and two outputs, the X4 can start external equipment or receive status signals. Configure the logic in LabSolutions to avoid conflicts, especially when integrating third-party devices that expect dry-contact closures.
The system supports up to eight controllable units (four solvent delivery, one autosampler, four column ovens, two detectors). Exceeding this without the expansion option will prevent recognition of additional modules. Plan the configuration accordingly.
Selection & Integration Q&A
Choose the X4 when you need to control multiple units (up to 8, or 12 with option) including multiple solvent delivery units, ovens, and detectors. For single-unit or basic setups, a lower-tier controller may suffice, but the X4 offers expandability and integrated touch-panel monitoring.
The X4 communicates via Ethernet to the PC and controls units through the system bus. Ensure all modules are compatible with LabSolutions and that the PC meets software requirements. Power can be supplied directly or from the solvent delivery unit; check the delivery unit's power budget.
The operating temperature range is specified as 35.0 °C (likely maximum). Install in a stable, indoor laboratory environment away from direct heat sources. Continuous duty is supported, but ensure adequate ventilation around the unit.