Shimadzu Nexis GC 2060
Shimadzu ·Made in Japan · In Active Production

Shimadzu Nexis GC 2060

Shimadzu Nexis GC 2060 — Chromatographs.

The Shimadzu Nexis GC 2060 is a gas chromatograph from Shimadzu's Nexis series, designed for analytical separation and quantification of volatile and semi-volatile compounds. As a member of the Nexis GC-2060 family, it is positioned as a routine analytical instrument for laboratories requiring reliable gas chromatography performance. Its primary purpose is to serve as the core separation and detection module in a gas chromatography system, integrating with autosamplers, detectors, and data handling software.

Direct drop-in replacements

100%
match
⚖️ Compare
⚖️ Compare
71%
match
⚖️ Compare

Full specifications

Core Performance & Functional Specifications
Detector types FID, TCD
Nexis GC-2060: FID, TCD, FTD, ECD, FPD
Injection unit types mfr SPL, MMI, PTV (Nexis GC-2060)
Injection volume (MMI large volume) mfr 100 μL (MMI large volume)
Injection volume (MMI) mfr 10 μL (MMI)
Detector precision (area RSD) (FTD, test analytes) mfr 0.134–0.158 % (FTD, test analytes)
Detector precision (RT RSD) (FTD, test analytes) mfr 0.004–0.006 % (FTD, test analytes)
Detector precision (RT deviation) (FTD, test analytes) mfr 0.0001–0.0003 min (FTD, test analytes)
Injection modes (MMI) mfr 5 (MMI)
Injection unit maintenance time saved (MMI) mfr >85 % (MMI)
Detector sensitivity increase (compared to previous models) mfr 20–25 % (compared to previous models)
Detector ready time from start-up mfr 30 min
Retention time RSD (Grob test mixture, n=10) mfr 0.004–0.006 % (Grob test mixture, n=10)
Peak area RSD (Grob test mixture, n=10) mfr 0.134–0.158 % (Grob test mixture, n=10)
Retention time deviation (Grob test mixture, n=10) mfr 0.0001–0.0003 min (Grob test mixture, n=10)
Minimum Detectable Quantity (MDQ) (GC-2060, N2/He makeup gas) mfr 1.0 pg C/s (GC-2060, N2/He makeup gas)
Minimum Detectable Quantity (MDQ) (Previous Model) mfr 1.2 pg C/s (Previous Model)
Nozzle Materials mfr Metal (GC-2060)
Nozzle Materials (Previous Model) mfr Metal & Quartz (Previous Model)
Makeup Gas Types (GC-2060, cylinder-free OK) mfr He / N2 / Air / O2 (GC-2060, cylinder-free OK)
Makeup Gas Types (Previous Model) mfr He / N2 (Previous Model)
Gas supply configuration (Hy/Air Mode, cylinder-free) mfr Air Compressor (+ Air Purifier) (Hy/Air Mode, cylinder-free)
Gas supply configuration (Hy/Ox Mode, cylinder-free) mfr PEAK Intura H2/O2 Generator (Hy/Ox Mode, cylinder-free)
Gas supply configuration (Regular Mode, with gas cylinders) mfr Gas Cylinders (≥ 2 types) (Regular Mode, with gas cylinders)
Injection mode (SPL) mfr Split / Splitless (SPL)
Injection mode (PTV) mfr Programmed Temperature Vaporization (PTV)
Injection mode (LVI) mfr Large Volume Injection (LVI)
Injection mode (Direct) mfr Direct Injection (Simple OCI) (Direct)
Injection mode (Manual TD) mfr Thermal Desorption/Extraction (Manual TD)
Maximum heating rate (Manual TD) mfr 1200 °C/min (Manual TD)
Maintenance downtime for liner replacement / column cut (MMI) mfr 5 min (MMI)
Maintenance downtime for liner replacement / column cut (stand-alone SPL) mfr 40 min (stand-alone SPL)
Comparable SPL performance, C8–C44 splitless injection (MMI vs SPL) mfr 100 ppm (MMI vs SPL)
Dimensions, Weight & Mechanical Design
Height 525 mm (Nexis GC-2060)
Width 515 mm (Nexis GC-2060)
Standards, Safety & General Data
EN 14103 FAME quantitation, total ester content (MMI vs SPL) mfr 19.0–25.0 (MMI vs SPL)

Description

Construction and Series Positioning

The Nexis GC 2060 is a gas chromatograph (GC) manufactured by Shimadzu. It belongs to the Nexis GC-2060 series, which typically includes models with varying detector configurations and automation levels. Without sibling model data, precise positioning relative to other Nexis variants cannot be stated; however, the 2060 designation generally indicates a standard-capability GC in the Nexis line. ### Behavior Under Load and Media

No digitized curve points or detailed performance specifications (e.g., temperature programming rates, carrier gas flow ranges, detector sensitivity) are provided. Therefore, the operational behavior under different loads or media cannot be characterized from the given facts. Consequently, details such as power requirements, communication interfaces, and control software are not included in this card.

Integration & Operating Notes

Control & I/O
Control interfaces and software compatibility not detailed

The facts do not specify the control interfaces (e.g., Ethernet, RS-232) or the compatible software (e.g., LabSolutions). The engineer should verify the integration requirements with existing laboratory data systems and autosamplers by consulting the official Shimadzu Nexis GC 2060 manual.

Shimadzu Nexis GC 2060 product documentation (not provided
Maintenance
Maintenance schedule and consumables not specified

The facts do not include maintenance intervals, replacement parts, or consumables (e.g., septa, liners, columns). The engineer should consult the official Shimadzu Nexis GC 2060 manual for recommended maintenance procedures and a list of required consumables to ensure uninterrupted operation.

Shimadzu Nexis GC 2060 product documentation (not provided

Selection & Integration Q&A

What maintenance items and consumables are required for the Nexis GC 2060, and are they included in the base delivery?

Typically, consumables are not included in the base delivery and must be ordered separately. Consult the official Shimadzu Nexis GC 2060 manual for recommended maintenance intervals and a list of required parts.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
c184-e056
Datasheet ·8,5 МБ ·11 pp.
View PDF
PDF
c184-e058
Datasheet ·806,2 КБ ·2 pp.
View PDF
PDF
c184-e060
Datasheet ·824,3 КБ ·2 pp.
View PDF
PDF
c184-e059
Datasheet ·887,6 КБ ·2 pp.
View PDF