Shimadzu Uwux Series
Shimadzu ·Made in Japan · In Active Production

Shimadzu Uwux Series

Shimadzu Uwux Series — Laboratory balances.

The Uwux Series is a family of Shimadzu laboratory balances covering capacities from 220 g to 1020 g with 0.001 g resolution. This 1020 g / 0.001 g configuration uses a 110 mm round pan and weighs 3.4 kg, distinguishing it as the highest-capacity variant in the series. It is intended for precise gravimetric measurement in laboratory workflows where readability of 1 mg is required.

Full specifications

Core Performance & Functional Specifications
Capacity (UW/UX, 0.001 g models) mfr 1020 g (UW/UX, 0.001 g models)
Capacity (UW/UX, 0.01 g models) mfr 6200 g (UW/UX, 0.01 g models)
Capacity (UW/UX, 0.1 g models) mfr 8200 g (UW/UX, 0.1 g models)
Repeatability (σ) (0.001 g models) mfr ≤0.001 g (0.001 g models)
Repeatability (σ) (0.01 g models) mfr ≤0.01 g (0.01 g models)
Repeatability (σ) (0.1 g models) mfr ≤0.08 g (0.1 g models)
Linearity (0.001 g models) mfr ±0.003 g (0.001 g models)
Linearity (0.01 g models) mfr ±0.02 g (0.01 g models)
Linearity (0.1 g models) mfr ±0.1 g (0.1 g models)
Capacity (TXC323L/TWC323L) mfr 320 ct (TXC323L/TWC323L)
Capacity (TXC623L/TWC623L) mfr 620 ct (TXC623L/TWC623L)
Pan size (TXC/TWC series) mfr 80 mm dia (TXC/TWC series)
Repeatability (TXC/TWC series) mfr 0.001 ct (TXC/TWC series)
Linearity (TXC/TWC series) mfr ±0.002 ct (TXC/TWC series)
Dimensions (TXC/TWC series) mfr 206(W)×291(D)×241(H) mm (TXC/TWC series)
Capacity (TX4202L) mfr 4200 g (TX4202L)
Capacity (TX3202L) mfr 3200 g (TX3202L)
Capacity (TX2202L) mfr 2200 g (TX2202L)
Capacity (TX423L/TW423L) mfr 420 g (TX423L/TW423L)
Capacity (TX323L/TW323L) mfr 220 g (TX323L/TW323L)
Pan size (TX4202L/TX3202L/TX2202L) mfr 167(W)×181(D) mm (TX4202L/TX3202L/TX2202L)
Pan size (TX423L/TW423L, TX323L/TW323L) mfr 110 mm dia (TX423L/TW423L, TX323L/TW323L)
Repeatability (TX4202L/TX3202L/TX2202L) mfr ≤0.01 g (TX4202L/TX3202L/TX2202L)
Repeatability (TX423L/TW423L, TX323L/TW323L) mfr ≤0.001 g (TX423L/TW423L, TX323L/TW323L)
Linearity (TX4202L/TX3202L/TX2202L) mfr ±0.02 g (TX4202L/TX3202L/TX2202L)
Linearity (TX423L/TW423L, TX323L/TW323L) mfr ±0.002 g (TX423L/TW423L, TX323L/TW323L)
Dimensions (TX4202L/TX3202L/TX2202L) mfr 200(W)×291(D)×80(H) mm (TX4202L/TX3202L/TX2202L)
Dimensions (TX423L/TW423L, TX323L/TW323L) mfr 206(W)×291(D)×241(H) mm (TX423L/TW423L, TX323L/TW323L)
Interfaces, Connections & Control
Minimum display (220–1020 g models) mfr 0.001 g (220–1020 g models)
Minimum display (2200–6200 g models) mfr 0.01 g (2200–6200 g models)
Minimum display (420–8200 g models) mfr 0.1 g (420–8200 g models)
Minimum display (TXC/TWC series) mfr 0.001 ct (TXC/TWC series)
Minimum display (TX4202L/TX3202L/TX2202L) mfr 0.01 g (TX4202L/TX3202L/TX2202L)
Minimum display (TX423L/TW423L, TX323L/TW323L) mfr 0.001 g (TX423L/TW423L, TX323L/TW323L)
Operating Conditions, Environment & Protection
Operating temperature 5~40 °C (TX/TW series)
Standards, Safety & General Data
Response time (standard models) mfr 1.5–2.5 s (standard models)

Description

Construction and series positioning

Integration & Operating Notes

Process Limits
Do not exceed 1020 g gross load on the pan

The rated weighing range is 1020 g; exceeding it risks overloading the sensor and invalidating results. Tare and container weight count toward this limit, so the usable sample mass is reduced accordingly.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the 1020 g variant instead of a lower-capacity Uwux model?

Pick the 1020 g model when sample plus container mass approaches or exceeds the 220–820 g ranges of the other Uwux variants while 1 mg readability is still required. If routine loads stay well below 820 g, a lower-capacity sibling gives the same 0.001 g display in the same 191 × 317 × 79 mm housing.

What environmental and duty-cycle limits apply to installation?

No temperature, humidity or duty-cycle figures are given in the supplied facts. Because the display resolves 0.001 g, place the 3.4 kg unit on a rigid bench away from drafts and vibration; confirm the rated ambient range and warm-up time from the manual before continuous use.

What maintenance and accessories are needed beyond the base unit?

The supplied facts contain no maintenance schedule, calibration interval or accessory list. The base delivery should be confirmed against the manual for items such as draft shield, leveling feet, calibration weights and interface cables, none of which are documented here.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
UW/UX Series - Electronic Balances
Datasheet ·411,1 КБ ·4 pp.
View PDF
PDF
balance
Datasheet ·1,7 МБ ·6 pp.
View PDF
PDF
321-78426
Manual ·4,1 МБ ·130 pp.
View PDF