Waters SFC Prep 150 MGM System for Scalable Sample Purification
Waters SFC Prep 150 MGM System for Scalable Sample Purification — Chromatographs with Flow rate 150 milliliter/minute, Max pressure 30 megapascal.
The Waters SFC Prep 150 MGM System is a preparative supercritical fluid chromatography (SFC) instrument configured with a Mass-Guided (MGM) fraction collection system, enabling scalable sample purification. It delivers flow rates from 0.50 to 150.00 mL/min (combined CO2 and co-solvent) at pressures up to 6000 psi (roll-off to 5000 psi at 150 mL/min), with a maximum pressure rating of 10,000 psi. This modification is distinguished by its MGM detection and automated fraction collection, making it suitable for high-recovery purification of compounds from complex mixtures.
Full specifications
| Flow rate | 150 mL/min |
| Max pressure | 300 bar |
| Injection volume | 9500 µL |
| Operating flow rate range mfr | 20 to 150 mL/min, combined CO2 and co-solvent |
| Recovery mfr | >90% (within total flow rate range) |
| Pressure rating mfr | 10,000 psi |
| Max operating pressure mfr | 8700 psi |
| Flow range mfr | 20 to 200 g/min |
| Wetted materials mfr | 316 stainless-steel, 440C, 17–4PH stainless-stee |
| Number of solvents mfr | Four solvents on the Solvent Select Valve (SSV) |
| Solvent conditioning mfr | Sparging one channel per solvent |
| Operating flow rate range mfr | 0.50 to 150.00 mL/min, in 0.01 mL/min increments |
| Maximum operating pressure mfr | 6000 psi up to 100 mL/min, roll off to 5000 psi |
| Plunger seal wash mfr | Integral, active, programmable |
| Delay volume mfr | <6.5 mL |
| Compressibility compensation mfr | Automatic and continuous |
| Priming mfr | Self prime from solvent container on floor with |
| Compositional accuracy mfr | +/-3% absolute (full scale) from 5% to 95%; and |
| Compositional precision mfr | Retention time variation <0.15 min SD (uracil/ca |
| Default syringe mfr | 5 mL |
| Default loop size mfr | 2 mL (Optional; 5 mL, and 10 mL) |
| Height | 12.3 inch |
| Weight | 84.0 lbs |
| Width | 14.3 inch |
| Ambient operating temperature mfr | 15 to 40 °C |
| Ambient operating humidity mfr | 20 to 80% RH at 40 °C (104 °F) |
Description
Construction and Positioning
- The SFC Prep 150 MGM is a preparative-scale SFC system built around a 150 mL/min binary pump (CO2 + co-solvent) with a four-solvent selection valve and integrated active plunger seal wash. - It is the mass-guided fraction collection variant of the SFC Prep 150 series; unlike non-MGM siblings, it includes a mass spectrometer for peak-based fraction triggering, enabling automated purification. - Wetted materials include 316 stainless steel, 440C, 17–4PH stainless steel, sapphire, GFPM, PTFE, and aluminum, ensuring compatibility with common organic solvents and CO2. - The system footprint is compact: 312.42 mm height, 363.22 mm width, 38.1 kg weight. ### Behavior Under Load and in Different Media
- The pump operates from 0.50 to 150.00 mL/min in 0.01 mL/min increments, with compositional accuracy of ±3% absolute (full scale) from 5% to 95% and from 1 to 150 mL/min. - Compositional precision is high: retention time variation <0.15 min SD (uracil/caffeine; tested at 1, 5, 20, 50, 150 mL/min; 70:30 water/methanol dial-a-mix). - Maximum operating pressure is 6000 psi up to 100 mL/min, rolling off to 5000 psi at 150 mL/min; the pressure rating is 10,000 psi, providing a safety margin. - Recovery is >90% within the total flow rate range, and the system supports flow rates from 20 to 200 g/min (mass-based). - The delay volume is <6.5 mL, and compressibility compensation is automatic and continuous, ensuring stable gradient performance. ### Installation, Connection, and Operation
- The system requires a 5 mL default syringe and a 2 mL default loop (optional 5 mL and 10 mL loops) for sample injection; injection volume up to 9500 µL is achievable with larger loops. - Priming is self-priming from solvent containers on the floor with dry lines, simplifying setup. - Ambient operating conditions: 15–40 °C, 20–80% RH at 40 °C (non-condensing). - The integral, active, programmable plunger seal wash extends seal life and reduces maintenance.
Integration & Operating Notes
The maximum operating pressure is 6000 psi up to 100 mL/min, but rolls off to 5000 psi at 150 mL/min. Exceeding these limits can cause overpressure, potentially damaging seals or the column. Always verify backpressure at the target flow rate, especially when using small-particle columns or high-viscosity modifiers.
The system achieves >90% recovery only when the total flow rate (combined CO2 and co-solvent) is within the specified range of 20 to 150 mL/min. Operating outside this range may reduce recovery and compromise purification yield. Ensure method flow rates are set accordingly.
The integral, active, programmable plunger seal wash must be configured and maintained to prevent seal wear and leaks. Regularly check wash solvent levels and program wash cycles according to the instruction manual. Neglecting this can lead to premature seal failure and downtime.
Selection & Integration Q&A
Choose the MGM variant when mass-guided fraction collection is needed for automated purification of unknown or complex samples. For simpler, UV-based purification, a non-MGM sibling may suffice. The MGM adds a mass spectrometer for peak-triggered collection, enhancing recovery and purity.
The system includes an integrated mass spectrometer for MGM operation. Ensure the MS is compatible with SFC flow rates (up to 150 mL/min) and pressures. The fraction collector must handle the outlet flow and be triggered by the MS signal. Refer to the manual for specific interface connections.
The base system includes a 5 mL syringe and 2 mL loop; optional 5 mL and 10 mL loops are available separately. Consumables such as columns, solvents, and replacement seals are not included. Regular maintenance includes seal wash solvent replacement and pump seal inspection per the manual.
Dimensional Drawings & Technical Documentation
Dimensional drawings
Click drawing to inspect vector dimensions