Waters SQ Detector 2
Waters ·Made in USA · In Active Production

Waters SQ Detector 2

Waters SQ Detector 2 — Mass spectrometers.

The Waters SQ Detector 2 is a single-quadrupole mass spectrometer detector designed for routine LC-MS analyses. As a standalone detector within the Waters SQ series, it provides nominal-mass confirmation and quantification for laboratories requiring a compact, benchtop solution. Its primary purpose is to serve as a selective detector in liquid chromatography systems, delivering mass spectral data for target compound identification.

Direct drop-in replacements

Shimadzu
Axima Assurance
0%
match
⚖️ Compare
Shimadzu
Axima Confidence
0%
match
⚖️ Compare
0%
match
⚖️ Compare
Shimadzu
GC-MS Qp2020 NX
0%
match
⚖️ Compare

Full specifications

Description

Construction and Positioning

The SQ Detector 2 is a single-quadrupole mass spectrometer, forming part of Waters' SQ Detector series. This model is configured as a detector unit for integration with liquid chromatography systems. Integration and operating notes are therefore limited to general engineering considerations for mass spectrometer detectors.

Integration & Operating Notes

Mounting
Benchtop installation requires stable, level surface

Mass spectrometers are sensitive to vibration and orientation; ensure the instrument is placed on a rigid, level bench free from excessive vibration to maintain performance and prevent internal damage.

General engineering practice for mass spectrometers
Electrical
Verify power requirements from instrument label

The SQ Detector 2 requires a specific AC power supply; confirm voltage, frequency, and current draw from the instrument's rating label or manual before connection to avoid electrical damage.

General engineering practice for laboratory instrumentation
Process Limits
Operate within specified temperature and humidity range

Laboratory environment must be maintained within the instrument's specified operating temperature and humidity limits to ensure stable performance and prevent condensation-related faults.

General engineering practice for mass spectrometers

Selection & Integration Q&A

When should I choose the SQ Detector 2 over other single-quadrupole models in the Waters SQ series?

The SQ Detector 2 is intended for routine LC-MS detection where nominal-mass confirmation and quantification are required. Without sibling data, selection should be based on required mass range, sensitivity, and compatibility with your LC system; consult Waters specifications for comparative performance.

What are the requirements for connecting the SQ Detector 2 to an LC system and a data system?

The detector requires a compatible LC interface (e.g., ESI or APCI source) and connection to a control/data system via Ethernet or similar. Ensure the LC flow rate and mobile phase composition are within the detector's specified limits, and use appropriate tubing and fittings.

What maintenance is required for the SQ Detector 2, and what consumables are needed?

Regular maintenance includes cleaning the ion source, replacing the capillary or skimmer, and checking vacuum pump oil. Consumables such as source gaskets, capillaries, and filters are not included in base delivery and should be stocked. Service intervals depend on usage; refer to the manual for schedules.

Dimensional Drawings & Technical Documentation

Dimensional drawings

performance curve

Click drawing to inspect vector dimensions

Technical documentation

PDF
Waters Driver Pack 2018 Release 1 Version 1.71 Certificate of Structural Integrity
Manual ·156,5 КБ ·1 pp.
View PDF