Waters SQ Detector 2
Waters SQ Detector 2 — Mass spectrometers.
The Waters SQ Detector 2 is a single-quadrupole mass spectrometer detector designed for routine LC-MS analyses. As a standalone detector within the Waters SQ series, it provides nominal-mass confirmation and quantification for laboratories requiring a compact, benchtop solution. Its primary purpose is to serve as a selective detector in liquid chromatography systems, delivering mass spectral data for target compound identification.
Direct drop-in replacements
Full specifications
Description
Construction and Positioning
The SQ Detector 2 is a single-quadrupole mass spectrometer, forming part of Waters' SQ Detector series. This model is configured as a detector unit for integration with liquid chromatography systems. Integration and operating notes are therefore limited to general engineering considerations for mass spectrometer detectors.
Integration & Operating Notes
Mass spectrometers are sensitive to vibration and orientation; ensure the instrument is placed on a rigid, level bench free from excessive vibration to maintain performance and prevent internal damage.
The SQ Detector 2 requires a specific AC power supply; confirm voltage, frequency, and current draw from the instrument's rating label or manual before connection to avoid electrical damage.
Laboratory environment must be maintained within the instrument's specified operating temperature and humidity limits to ensure stable performance and prevent condensation-related faults.
Selection & Integration Q&A
The SQ Detector 2 is intended for routine LC-MS detection where nominal-mass confirmation and quantification are required. Without sibling data, selection should be based on required mass range, sensitivity, and compatibility with your LC system; consult Waters specifications for comparative performance.
The detector requires a compatible LC interface (e.g., ESI or APCI source) and connection to a control/data system via Ethernet or similar. Ensure the LC flow rate and mobile phase composition are within the detector's specified limits, and use appropriate tubing and fittings.
Regular maintenance includes cleaning the ion source, replacing the capillary or skimmer, and checking vacuum pump oil. Consumables such as source gaskets, capillaries, and filters are not included in base delivery and should be stocked. Service intervals depend on usage; refer to the manual for schedules.
Dimensional Drawings & Technical Documentation
Dimensional drawings
Click drawing to inspect vector dimensions