Operating Instructions — VSI 300 vacuum pump (BA 832-42-FU, EN)

Technical Reference Summary

Covered Models & Document Scope

This document covers the screw vacuum pump S-VSI 300 (42) FU, a twin-screw dry vacuum pump with integrated frequency converter (9.0 kW variant referenced for outlet back-pressure limits). It describes the standard continuous-flow water cooling version and optional control unit, thermostatic water valve, and circulation cooling system.

Section-by-Section Technical Breakdown

pp. 12-16
Setup and Operation

Describes the machine layout, data plates, operating principle of the twin-screw dry pump, application ranges, and cooling variants. The pump is a contactless, dry-running twin-screw machine with oil-lubricated gearbox and bearings, speed-controlled by an integrated frequency converter.

  • Twin-screw vacuum pump with two parallel contactless dry screw rotors; gas is enclosed and gradually compressed to atmospheric pressure.
  • Gearbox and compression chamber are separated by special seals; an atmospherically ventilated area between them can be loaded with sealing gas (special version).
  • Suitable for evacuation of closed systems or continuous vacuum in the intake pressure range 0.1 to 1000 mbar (abs.).
  • Particularly suited for extremely damp gases; water vapour compatibility is very high.
  • Three-phase motor with integrated frequency converter enables continuous speed control.
  • Standard continuous-flow cooling: fresh water flows continuously through the cavity of the double-walled compressor housing.
  • Optional control unit evaluates monitoring signals and controls motor and solenoid valve.
  • Optional circulation cooling uses a thermostatically controlled three-way valve to bypass the heat exchanger during start-up; temperature switch controls water temperature and flow switch controls flow rate.
pp. 17-21
Installation

Covers preparation of the installation site, mounting requirements, pipe connections, cooling water connection, oil filling, and electrical connection of the drive. Key limits include horizontal setup, minimum clearances, cooling water quality and pressure limits, and power supply tolerances.

  • Machine must be set up horizontally; foundation must be plane, even, and able to carry the machine weight.
  • Cooling air inlets and outlets must be at least 30 cm from the next walls; cooling air coming out must not be sucked in again.
  • Suction pipe must be connected by hand only; too narrow or too long suction pipes reduce suction capacity.
  • Exhaust air outlet must not be closed or restricted; prevent liquids from accumulating in the exhaust line.
  • Cooling water must be pH-neutral, clean and filtered; operating pressure must not exceed 6 bar; temperature must be between 15 and 50 °C.
  • For circulating cooling systems, rinse the customer pipe network and install a filter element; mix cooling water with at least 20 % anti-freeze to prevent frost damage.
  • Fill lubricating oil at oil filling points up to the middle of the sight glasses.
  • Electrical installation must be by a qualified electrician observing EN 60204; main switch provided by operating company.
  • Frequency converter input: 3 AC 400 V -15 % to 480 V +10 %, 47 to 63 Hz, TN/TT network; use suitable cable fittings for IP55.
pp. 22-24
Commissioning and Decommissioning

Describes commissioning checks including rotation direction and overrun procedure, as well as decommissioning, storage, and re-commissioning steps. Includes warnings about hot surfaces, noise, and condensate formation.

  • Check rotation direction by briefly starting the motor (max. two seconds); when looking at the motor fan, it must rotate clockwise.
  • Use a phase sequence indicator to check the direction of rotation (anti-clockwise).
  • Before standstill of more than 2 hours, overrun the vacuum pump at least 10 minutes with dry air at 50–100 mbar (abs.) to remove moisture and contamination.
  • Drain condensate from the silencer regularly and depending on application; do not drain when machine is at operating temperature.
  • Decommissioning: switch off, close cut-off devices, disconnect power, depressurise, remove pipes, seal connections, drain cooling water and condensate.
  • Re-commissioning: check condition of machine, then follow installation and commissioning instructions.
pp. 25-31
Maintenance and Repair

Provides maintenance intervals and procedures for oil change, air filtering, coupling inspection, cooling system, and integrated frequency converter. Includes oil specification, filter cleaning, and spare parts ordering information.

  • Monthly: check pipes and screws for leaks and tight fit; check terminal box and cable inlet holes; clean cooling ribs; check oil level; check cooling water system and pipes.
  • Oil change every 7,500 operating hours; oil viscosity ISO VG 150 per DIN 51519, designation CLP HC 150; recommended GEARLUBE 150 or equivalent.
  • Oil fill quantity 1.9 l total (1.1 l at H + 0.8 l at H1).
  • Clean intake air mesh filter and gas ballast valve filter depending on dirtiness of discharged medium.
  • Check coupling sprocket for wear at least once a year; defective sprockets may lead to rotor shaft breaking.
  • Clean dirt trap in continuous-flow cooling depending on contamination of coolant.
  • For integrated frequency converter maintenance, see operating instructions 610.00260.01.000-DE chapter 3.2.5.
  • Spare parts ordered per spare parts list E 832/4 for S-VSI 300 (42); use only original or approved parts.
pp. 33
Technical Data

Lists key technical data for the S-VSI 300 (42) FU including noise levels, weight, dimensions, connections, oil fill quantity, and cooling water requirements.

  • Sound pressure level (max.) at 200 mbar (abs.) to 0.1 mbar (abs.) per EN ISO 3744: 83 dB(A) at 60 Hz, tolerance ±3 dB(A).
  • Sound power level: 89 dB(A) at 60 Hz.
  • Weight: 348 kg; length: 1297 mm; width: 455 mm; height: 663 mm.
  • Vacuum connection: G 2.
  • Oil fill quantity: 1.9 l (1.1 l at H + 0.8 l at H1).
  • Cooling water consumption: max. 6.7 l/min at max. flow temperature 50 °C; cooling water pressure max. 6 bar.

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Ambient and suction temperature must be between 5 and 40 °C. p.7 ↗ Operation outside this range requires consultation with the manufacturer; ensure installation environment meets these limits. S-VSI 300 (42) FU
Permissible back pressure on the outlet side for S-VSI (42) 9.0 kW is < +0.2 bar. p.7 ↗ Exhaust line must be sized and routed to avoid exceeding this back pressure; do not restrict or close the air vent. S-VSI (42) 9.0 kW
Intake pressure range for continuous vacuum: 0.1 to 1000 mbar (abs.). p.14 ↗ Select pump for applications within this range; outside range consult manufacturer. S-VSI 300 (42) FU
Cooling water operating pressure must not exceed 6 bar; temperature must be between 15 and 50 °C. p.19 ↗ Install pressure regulator or ensure supply pressure is within limit; use suitable water quality per info sheet I 832-EN. S-VSI 300 (42) FU
Cooling water consumption max. 6.7 l/min at max. flow temperature 50 °C. p.33 ↗ Size cooling water supply and return lines accordingly; ensure sufficient flow to prevent overheating. S-VSI 300 (42) FU
Frequency converter input voltage: 3 AC 400 V -15 % to 480 V +10 %; input frequency 47 to 63 Hz; suitable network TN/TT. p.21 ↗ Verify site power supply matches these tolerances; use appropriate cable fittings to maintain IP55 protection. S-VSI 300 (42) FU
Oil viscosity must comply with ISO VG 150 per DIN 51519; designation CLP HC 150; recommended GEARLUBE 150 or equivalent. p.26 ↗ Use only specified oil type; if changing oil type, empty oil tank completely. S-VSI 300 (42) FU
Oil change interval: every 7,500 operating hours. p.26 ↗ Plan maintenance schedule accordingly; change oil when machine is at operating temperature and in atmospherically ventilated area. S-VSI 300 (42) FU
Oil fill quantity: 1.9 l total (1.1 l at H + 0.8 l at H1). p.33 ↗ Fill each oil filling point to middle of respective sight glass; do not overfill. S-VSI 300 (42) FU
Cooling air inlets and outlets must be at least 30 cm from the next walls. p.17 ↗ Ensure installation site provides sufficient clearance for cooling air flow; do not recirculate exhaust air. S-VSI 300 (42) FU
Overrun at least 10 minutes with dry air at 50–100 mbar (abs.) before standstill of > 2 hours. p.23 ↗ Include overrun procedure in operating sequence to prevent condensate and deposits that may block restart. S-VSI 300 (42) FU
Rotation direction: when looking at the motor fan, it must rotate clockwise; check by briefly starting motor (max. two seconds). p.23 ↗ Incorrect rotation may damage machine; use phase sequence indicator to verify. S-VSI 300 (42) FU
Sound pressure level (max.) 83 dB(A) at 60 Hz, tolerance ±3 dB(A); sound power level 89 dB(A). p.33 ↗ Use ear protection when spending long time near running machine. S-VSI 300 (42) FU
Weight: 348 kg; length: 1297 mm; width: 455 mm; height: 663 mm. p.33 ↗ Foundation must be designed to carry weight; ensure sufficient space for installation and maintenance. S-VSI 300 (42) FU
Vacuum connection: G 2. p.33 ↗ Suction pipe must be connected by hand only; use suitable mating flange or fitting. S-VSI 300 (42) FU
Temperature control factory-provided adjustment: Tmax = 60 °C; thermostatic water valve (optional) factory-provided adjustment: Tmax = 55 °C. p.15 ↗ Monitor cooling water temperature; adjust if necessary per application. S-VSI 300 (42) FU with control unit
Solenoid valve control voltage: 24 V DC. p.15 ↗ Ensure control power supply provides 24 V DC for cooling system solenoid valve. S-VSI 300 (42) FU with control unit
Safety valve protects from incorrect operating pressure of cooling water > 6 bar. p.15 ↗ Safety valve is set to protect cooling circuit; do not exceed 6 bar supply pressure. S-VSI 300 (42) FU
Storage ambient conditions: relative humidity 0 % to 80 %, storage temperature -10 °C to +60 °C; do not store for more than 6 months. p.11 ↗ Store in dry, dust-free, vibration-free environment; follow storage guideline I 150-EN for longer periods. S-VSI 300 (42) FU
An output reduction is noticeable when installed at more than 1000 m above sea level. p.17 ↗ For high-altitude installations, contact manufacturer for application-specific advice. S-VSI 300 (42) FU

Faults & Troubleshooting

Code / Symptom Possible Cause Remedy Note
Machine does not start or the frequency converter displays an error message p.32 ↗ Faults in the integrated frequency converter see the enclosed operating instructions 610.00260.01.000-DE chapter 8 –
Suction capacity is insufficient p.32 ↗ The mesh filter is dirty Clean / replace the mesh filter Chapter 7.2.2 Chapter 7.4
Suction capacity is insufficient p.32 ↗ The suction pipe is too long or too narrow Check the hose and/or the pipe Chapter 5.3
Suction capacity is insufficient p.32 ↗ Machine or system leaking Check the pipework and screw connections for leaks and check for tight fit Chapter 7.2
Final pressure (max. vacuum) is not reached p.32 ↗ Machine or system leaking Check the pipework and screw connections for leaks and check for tight fit Chapter 7.2
Final pressure (max. vacuum) is not reached p.32 ↗ Not enough cooling water Observe cooling water consumption Chapter 9
Final pressure (max. vacuum) is not reached p.32 ↗ The mesh filter is dirty Clean / replace the mesh filter Chapter 7.2.2 Chapter 7.4
Machine gets too hot p.32 ↗ Ambient or intake temperatures too high Ensure proper use Chapter 2.3
Machine gets too hot p.32 ↗ Cooling air supply is obstructed Check ambient conditions Chapter 5.1
Machine gets too hot p.32 ↗ Cooling air supply is obstructed Clean the cooling ribs Chapter 7.2
Machine gets too hot p.32 ↗ The cooling water system is obstructed Check the cooling water system and the lead-in pipes Chapter 7.2
Machine gets too hot p.32 ↗ Not enough cooling water Observe cooling water consumption Chapter 9
Machine gets too hot p.32 ↗ Cooling water inflow is too hot Observe the max. intake temperature Chapter 9
The machine makes a strange noise p.32 ↗ Deposits on the rotors Clean the working space and the rotors Elmo Rietschle Service