Operating Instructions — VSI 300 vacuum pump (BA 832-42-EN, ed. 1.0 20.7.2017, EN)

Technical Reference Summary

Covered Models & Document Scope

This document covers the S-VSI 300 screw vacuum pump series, including the Standard version (IV) and variants with corrosion-protective coating (XD), gas ballast valve, sealing gas unit, continuous flow cooling, water/air heat exchanger, water/water heat exchanger, circulation cooling, and control unit. Motor options include 5.5 kW and 7.5 kW. Additional instructions M 30, M 31, M 33 apply to specific variants.

Section-by-Section Technical Breakdown

pp. 12-17
Setup and Operation

Describes the design of the S-VSI 300, including the double-shaft screw principle, oil-lubricated gearbox, and standard flanged three-phase motor. Covers data plate information, areas of application, and cooling configurations (continuous flow, control unit, circulation cooling).

  • Double shaft screw vacuum pump with non-touching, dry-running screw rotors.
  • Gearbox and compression chamber separated by special seals; sealing gas option available.
  • Data plate includes type, serial number, year, speed, motor output, operating mode, suction capacity, ultimate vacuum.
  • Suitable for intake pressures 0.1 to 1000 mbar (abs.); max suction capacity 320 m3/h at 50 Hz.
  • 5.5 kW motor only for continuous operation S1; max volume to evacuate closed systems 80 l.
  • Cooling options: continuous flow (standard), control unit, circulation cooling.
pp. 18-22
Installation

Provides requirements for preparing the installation site, connecting pipes and cooling water, filling lubricating oil, and connecting the motor. Includes limits for counter pressure, cooling water quality, and electrical tolerances.

  • Machine must be set up horizontally; cooling air inlets/outlets at least 30 cm from walls.
  • Counter pressure limits: S-VSI 7.5 kW < +0.2 bar; S-VSI 5.5 kW < +30 mbar.
  • Cooling water: pH-neutral, clean, filtered; pressure max 6 bar; temperature 15-50 °C.
  • Oil filling up to middle of sight glasses; oil viscosity ISO VG 150 (CLP HC 150).
  • Motor electrical data per data plate; protection class IP 55, insulation class F.
  • Voltage deviation ±5%, frequency deviation ±2% permissible without derating.
pp. 23-25
Commissioning and Decommissioning

Covers checking rotation direction, post-run procedure to remove moisture, decommissioning steps, and re-commissioning checks. Emphasizes correct rotation direction and post-run with dry air.

  • Check rotation direction: motor fan must rotate clockwise when looking at fan; use phase sequence indicator.
  • Post-run at 50-100 mbar (abs.) with dry air for minimum 10 minutes before shutdown >2 hours.
  • Decommissioning: switch off, disconnect power, depressurize, drain cooling water and condensate.
  • Re-commissioning: check condition, follow installation and commissioning sections.
pp. 26-30
Maintenance and Repair

Lists maintenance intervals and procedures for oil changes, air filtering, coupling inspection, and cooling system checks. Specifies oil change every 7,500 operating hours and annual coupling check.

  • Monthly: check pipes/screws for leaks, terminal box, clean cooling ribs, check oil level, check cooling water system.
  • Oil change every 7,500 operating hours; oil type ISO VG 150 (CLP HC 150).
  • Clean intake air mesh filter and gas ballast valve filter depending on dirt.
  • Check coupling sprocket at least once a year; replace if worn or damaged.
  • Clean dirt trap in cooling circuit depending on cooling liquid quality.
pp. 35
Technical Data

Provides technical specifications for S-VSI 300 with 5.5 kW and 7.5 kW motors, including sound pressure level, weight, dimensions, connections, oil quantity, and cooling water consumption.

  • Sound pressure level at 200 mbar (abs.) and 0.1 mbar (abs.): 74 dB(A) at 50 Hz for both; 76 dB(A) at 60 Hz for 7.5 kW.
  • Weight: 330 kg (5.5 kW), 335 kg (7.5 kW).
  • Dimensions: length 1297 mm, width 454 mm, height 580 mm.
  • Vacuum connection: G 2.
  • Oil quantity: 1.9 l (formula: 1.1 × H + 0.8 × H1).
  • Cooling water consumption: 6.7 l/min at max intake temperature 50 °C; max pressure 6 bar.

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Ambient and suction temperature must be between 5 and 40 °C. p.7 ↗ Ensure installation environment and process gas temperature stay within this range; contact manufacturer for outside conditions. S-VSI 300 all variants
Counter pressure limits: S-VSI 7.5 kW < +0.2 bar; S-VSI 5.5 kW < +30 mbar. p.19 ↗ Do not exceed these outlet pressures to avoid damage or reduced performance. S-VSI 300 5.5 kW and 7.5 kW
Cooling water operating pressure must not exceed 6 bar; temperature must be between 15 and 50 °C. p.20 ↗ Install pressure regulation if necessary and ensure water temperature is within range. S-VSI 300 with water cooling
Oil viscosity must comply with ISO VG 150 as per DIN 51519; designation CLP HC 150 (GEAR-LUBE 150 or equivalent). p.27 ↗ Use only specified oil to ensure proper lubrication and warranty compliance. S-VSI 300 all variants
Oil change interval: every 7,500 operating hours with clean operations. p.27 ↗ Plan maintenance schedule accordingly; more frequent changes may be needed for dirty processes. S-VSI 300 all variants
Motor protection: voltage deviation ±5%, frequency deviation ±2% permissible without derating. p.22 ↗ Verify power supply quality; use motor protection switch with delayed switch off. S-VSI 300 all variants
Cooling air inlets and outlets must be at least 30 cm away from adjacent walls. p.18 ↗ Ensure sufficient clearance for cooling air flow to prevent overheating. S-VSI 300 all variants
Maximum suction capacity with free suction is 320 m3/h at 50 Hz. p.15 ↗ Use for sizing suction lines and system capacity; refer to data sheet for pressure-dependent curves. S-VSI 300 all variants
When evacuating closed systems, the volume to be evacuated must be max. 80 l. p.15 ↗ Do not exceed this volume for closed-system evacuation to avoid overload. S-VSI 300 with 5.5 kW motor
Post-run at 50-100 mbar (abs.) with dry air for minimum 10 minutes before shutdown >2 hours. p.24 ↗ Prevents condensate and deposits that could block rotors on restart. S-VSI 300 all variants
Cooling water consumption: 6.7 l/min at max intake temperature 50 °C. p.35 ↗ Ensure cooling water supply meets this flow rate for proper cooling. S-VSI 300 with water cooling
Oil quantity: 1.9 l (formula: 1.1 × H + 0.8 × H1). p.35 ↗ Use correct oil fill amount; check sight glasses to middle level. S-VSI 300 all variants
Sound pressure level: 74 dB(A) at 50 Hz for both 5.5 kW and 7.5 kW; 76 dB(A) at 60 Hz for 7.5 kW. p.35 ↗ Use ear protection when spending long time near running machine. S-VSI 300 5.5 kW and 7.5 kW
Vacuum connection: G 2. p.35 ↗ Ensure mating pipe connection is G 2; only screw pipes in by hand. S-VSI 300 all variants
Motor protection class IP 55, insulation class F. p.22 ↗ Suitable for dusty and humid environments; ensure proper electrical installation per EN 60204. S-VSI 300 all variants
Temperature control factory setting: Tmax = 60 °C; thermostatic water valve factory setting: Tmax = 55 °C. p.16 ↗ Verify settings for application; adjust if necessary. S-VSI 300 with control unit or thermostatic water valve
Solenoid valve control voltage: 24 V DC. p.16 ↗ Provide 24 V DC supply for cooling circuit control. S-VSI 300 with control unit
Safety valve protects from cooling water pressure > 6 bar. p.16 ↗ Safety valve is set to limit pressure; do not exceed 6 bar supply pressure. S-VSI 300 with water cooling
Coupling sprocket must be checked at least once a year; frequent starting and high ambient temperature reduce service life. p.30 ↗ Regular inspection prevents rotor shaft breakage due to worn coupling. S-VSI 300 all variants
Storage temperature: -10 °C to +60 °C; relative humidity 0% to 80%; storage not more than 6 months. p.11 ↗ Store in dry, dust-free, vibration-free environment; follow storage guidelines for longer periods. S-VSI 300 all variants

Faults & Troubleshooting

Code / Symptom Possible Cause Remedy Note
Machine is switched off by the motor protection switch p.33 ↗ Mains voltage/ Frequency does not correspond with the motor data Check by qualified electrician Section 5.5
Machine is switched off by the motor protection switch p.33 ↗ Connection to motor terminal board is not correct Check by qualified electrician Section 5.5
Machine is switched off by the motor protection switch p.33 ↗ Motor protection switch is not set correctly Check by qualified electrician Section 5.5
Motor protection switch is triggered too quickly p.33 ↗ Motor protection switch is triggered too quickly Use a motor protection switch with an overload-dependent delayed switch off that takes into consideration the short term excess current at start up (version with short circuit and overload trigger as per VDE 0660 Part 2 or IEC 947-4)
Suction capacity is insufficient p.33 ↗ The mesh filter is dirty Clean or replace the mesh filter Section 7.2.2, Section 7.4
Suction capacity is insufficient p.33 ↗ The suction pipe is too long or too narrow Check the hose or the pipe Section 5.3
Suction capacity is insufficient p.33 ↗ Machine or system leaking Check the pipework and screw connections for leaks and to ensure that they are firmly seated Section 7.2
Final pressure (max. vacuum) is not reached p.34 ↗ Machine or system leaking Check the pipework and screw connections for leaks and to ensure that they are firmly seated Section 7.2
Final pressure (max. vacuum) is not reached p.34 ↗ Too little cooling water Note cooling water consumption Section 9
Final pressure (max. vacuum) is not reached p.34 ↗ The mesh filter is dirty Clean or replace the mesh filter Section 7.2.2, Section 7.4
Machine gets too hot p.34 ↗ Ambient or intake temperature is too high Ensure it is being used properly Section 2.3
Machine gets too hot p.34 ↗ Cooling air supply is obstructed Check environmental conditions Section 5.1
Machine gets too hot p.34 ↗ Cooling air supply is obstructed Clean the cooling ribs Section 7.2
Machine gets too hot p.34 ↗ The cooling water system is obstructed Check the cooling water system and the pipes Section 7.2
Machine gets too hot p.34 ↗ Too little cooling water Note cooling water consumption Section 9
Machine gets too hot p.34 ↗ Cooling water inflow is too hot Note the max. intake temperature Section 9
The machine makes a abnormal noise p.34 ↗ Deposits on the rotors Clean the working space and the rotors Elmo Rietschle Service