Operating Instructions — vacuum pump (BA 893-EN, ed. 1.0 08.04.2024, EN)

Technical Reference Summary

Covered Models & Document Scope

Covers the contact-free running claw vacuum pumps C-VLU 401, 501 and 651 in standard version (CD) and XD version with corrosion-protective coating. XD adds a condensate drain and permits moist gases/water vapour. Document BA 893-EN, edition 1.0, 08.04.2024.

Section-by-Section Technical Breakdown

pp. 14-15
Product Overview and Functioning

Describes the double-shaft rotary piston (claw) principle with contact-free, dry-running rotors synchronised by an oil-lubricated gear pair. Lists component callouts including vacuum connection, exhaust silencer, condensate drain (XD only), inlet flange with non-return valve, cooling air paths, oil filling point, sight glass, oil drain with magnet, data plates and hot-surface warning. Explains the insulation hood and drum-fan cooling and the flanged three-phase standard motor drive.

  • Double-shaft rotary piston vacuum pump; claws roll against each other contact-free and dry.
  • Counter-rotating claw rotors synchronised by a gear pair in the oil-filled gearbox.
  • Gearbox and compression chamber separated by special seals; gearbox sealed with piston sealing rings and O-rings.
  • Integral non-return valve prevents the evacuated system from being ventilated after pump stop.
  • Cooling air is drawn through between compressor and insulation hood by a drum fan and discharged at the cooling air outlet.
  • XD model has a condensate drain (B2) on the silencer.
  • Hot surfaces > 70 °C are marked (Q).
pp. 15
Data Plate

Defines the data plate fields: model/size, serial number, year of construction, data matrix barcode, article number, speed 50/60 Hz, motor output 50/60 Hz, operating mode, pumping capacity 50/60 Hz and final pressure (abs.) 50/60 Hz. The barcode encodes material number (MA), production order (PR) and serial number (SC).

  • Data plate includes model/size, serial number, year of construction, article number.
  • Speed, motor output, operating mode, pumping capacity and final pressure are given for 50 Hz and 60 Hz.
  • Barcode encodes material number (MA), production order (PR) and serial number (SC).
  • Example plate shows C-VLU 501 CD, 60.00 mbar (abs), 515.0 m³/h, 11.00 kW, 2950/min, S1 100%.
pp. 16
Fields of Application

States continuous operation is possible at any pressure between 700 mbar (abs.) and an inlet pressure of 60 mbar (abs.). Gives free-suction pumping speeds at 50 Hz: 380 m³/h (401), 495 m³/h (501), 600 m³/h (651). Notes XD suitability for water-damp gases and restrictions for frequent switching or high ambient/inlet temperatures.

  • Continuous operation between 700 mbar (abs.) and 60 mbar (abs.) inlet pressure.
  • Pumping speed with free suction at 50 Hz: 380 m³/h (VLU 401), 495 m³/h (VLU 501), 600 m³/h (VLU 651).
  • XD design with corrosion-protective coating suitable for conveying water-damp gases (water vapour).
  • Frequent switching (approx. 10 times per hour) or high ambient/inlet temperatures may exceed motor winding and bearing temperature limits; contact manufacturer.
  • Outdoor installation requires protection from environmental influences (e.g. protective roof).
  • Minimum permissible end pressure is specified on the rating plate.
pp. 16
Accessories – Intake Filter

The intake filter is an option protecting the machine from dust and solids in the process gas. It is available with a paper filter or a polyester filter.

  • Intake filter available as option from Gardner Denver.
  • Paper filter or polyester filter versions.
  • Protects machine from dust and other solids in the process gas.
pp. 17-18
Installation – Preparation and Installation

Specifies installation conditions: free access from all sides, unobstructed ventilation, no external vibrations, no intake of hot exhaust air from other machines, accessible oil filling point/sight glass/drain, and at least 50 cm space around the machine for maintenance. Requires horizontal setup with max. 8° inclination in all directions, secure against tipping, level floor, and adequate load-bearing capacity. Cooling air inlets/outlets must be at least 30 cm from adjacent walls.

  • Provide at least 50 cm space around the machine for maintenance.
  • Machine may only be operated when set up horizontally; max. inclination 8° in all directions.
  • Secure machine against tipping over and falling; floor must be plane and even.
  • Bearing surface must carry the machine weight (see Technical Data).
  • Ambient temperature min. +5 °C, max. +40 °C.
  • Cooling air inlets and outlets at least 30 cm from adjacent walls; cooling air must not be recirculated.
  • Do not close ventilation grids and holes; ensure good aeration and venting of the installation room.
  • If a non-return valve is integrated in the pump, it may not be removed.
  • Installation on a firm base without anchoring is possible; flexible buffers recommended on a substructure.
  • Output reduction noticeable when installed at more than 1000 m above sea level; contact manufacturer.
pp. 18
Connection of Pipes

Covers removal of blind plugs/adhesive film from vacuum and exhaust connections, connection of pipes, and routing of exhaust air. Emphasizes that the exhaust air opening must not be closed or restricted, maximum permissible back pressure is +30 mbar, liquids must not accumulate in the exhaust line, and pipes must only be screwed in by hand with flexible connections if necessary.

  • Remove blind plug/adhesive film on vacuum connection (Fig. 2/A) and exhaust air outlet (Fig. 2/B) before connecting.
  • Exhaust air opening must not be closed or restricted; do not install blocking devices.
  • Maximum permissible back pressure: +30 mbar.
  • Prevent liquids from accumulating in the exhaust line.
  • Only screw in pipes by hand; use flexible connections if necessary.
  • Compensators recommended to avoid distorting the piping system.
  • Suction capacity is reduced if the inlet pipe is too narrow and/or too long.
  • Regularly check connected exhaust lines for pollution.
pp. 18
Check Lubricating Oil

Requires checking the lubricating oil level at the oil sight glass and topping up if necessary before commissioning. Refers to chapter 7.5 for oil details.

  • Check oil level at oil sight glass (Fig. 2/I).
  • Top up oil if necessary; see chapter 7.5.
pp. 19
Connect to the Energy Supply Network / Motor Connection

Electrical installation must be carried out by a qualified electrician observing EN 60204. The user must provide a main switch and a motor protection switch. Motors comply with DIN EN 60034, protection class IP 55 and insulation class F. Permissible tolerances are ±5 % voltage and ±2 % frequency. Motors above certain apparent power or start current limits are not designed for direct-on-line starting.

  • Electrical installation only by qualified electrician observing EN 60204.
  • Main switch and motor protection switch must be provided by the operating company.
  • Motor data must match mains network: current type, voltage, frequency, permitted current.
  • Motors comply with DIN EN 60034, IP 55, insulation class F.
  • Permissible voltage deviation ±5 % of nominal value; frequency deviation ±2 %.
  • AC motors >1.7 kVA, three-phase motors >5.2 kVA, or motors with start currents >60 A are not designed for direct start on the network.
  • Use star-delta starting, smooth starter or frequency converter where high starting torques must be reduced.
  • Direction of rotation must correspond to arrow on motor flange; check with phase sequence indicator.
  • Motor protection circuit breakers with delayed switch off recommended due to temporary excess current at cold start.
pp. 20
Connect Pressure Monitoring

Operation without pressure monitoring is not permitted. No pressure monitoring is fitted at the factory; the customer must install a system that switches off the pump or brings it to a safe state if pressure falls below the minimum permissible final pressure on the rating plate. Permissible tolerance is ±5 % pressure deviation relative to nameplate data.

  • Operation without pressure monitoring is not permitted.
  • No pressure monitoring fitted at factory; must be installed by customer.
  • If pressure falls below permissible final pressure, pump must be switched off or brought to safe operating state.
  • Minimum permissible final pressure is noted on the rating plate.
  • Permissible pressure deviation tolerance: ±5 % relative to nameplate data.
pp. 21-22
Start-up and Installation Check

Lists checks before start-up: no transport/assembly damage, safe horizontal standing, correct and leak-tight pipe connections, tight screw and flange connections, electrical installation per connection diagram, adequate ventilation, oil filled and level checked, pump and pipelines cleaned, optional accessories functional. Rotation direction check: brief start (max. 2 s), motor blower must rotate counter-clockwise when viewed from the motor blower.

  • Check for transport or assembly damage.
  • Verify vacuum pump stands safely and horizontally on the substrate.
  • Check correct connection and leak tightness of inlet and outlet pipelines.
  • Check tight fit of screw and flange connections.
  • Verify electrical installation complies with connection diagram.
  • Ensure installation room has adequate ventilation.
  • Check oil fill and oil level.
  • Clean vacuum pump and pipelines.
  • Check function of optional accessories if present.
  • Rotation direction check: start motor briefly (max. two seconds); when looking at the motor blower, it must rotate counter-clockwise.
  • Keep a distance of 1 m from outlet and inlet connections during rotation check.
pp. 22-23
Operation – Discharge Condensate

For XD models, condensate must be discharged regularly from the silencer through the condensate drain depending on application. Before decommissioning or shutdown longer than 2 hours, remove moisture and pollution by running the pump at 500 mbar (abs.) for at least 15–30 minutes with dry air. Do not discharge condensate manually while hot.

  • XD model: regularly discharge condensate from silencer through condensate drain depending on application.
  • Do not discharge condensate manually; allow machine to cool before draining.
  • Before shutdown >2 hours or decommissioning, run pump at 500 mbar (abs.) for at least 15–30 minutes with dry air to remove moisture and pollution.
  • Purging gas after-run recommended depending on use case; contact manufacturer.
pp. 23
Decommissioning, Storage and Recommissioning

Decommissioning requires disconnecting from power supply via main switch or plug and securing against unexpected restart. Electrical work must be carried out by an electrician. Storage conditions and recommissioning procedures are referenced.

  • Disconnect machine from power supply by main switch or plug and secure against unexpected restart.
  • Works on electrical installation must be carried out by an electrician.
  • See chapter 3.2 for storage conditions.
  • Recommissioning per chapter 6.4.
pp. 23-30
Maintenance and Repair

Covers ensuring operational safety, maintenance table, preparation for maintenance, cleaning the vacuum pump, lubricating oil (check/refill and oil change), air filter (mesh filter, filter silencer, intake filter accessory), motor and coupling, repair/service and spare parts. Specific procedures and intervals are detailed in subsections 7.1–7.9.

  • Maintenance table in chapter 7.2.
  • Clean vacuum pump per chapter 7.4.
  • Check/refill oil level per chapter 7.5.1; oil change per chapter 7.5.2.
  • Air filter maintenance: mesh filter (7.6.1), filter silencer (7.6.2), intake filter accessory (7.6.3).
  • Motor and coupling maintenance per chapter 7.7.
  • Repair/service per chapter 7.8; spare parts per chapter 7.9.
pp. 31-32
Errors – Table of Malfunctions

Provides a table of malfunctions, causes and remedies covering motor protection switch trips, insufficient suction capacity, failure to reach final pressure, overheating, and strange noise. Includes references to relevant chapters and notes that other malfunctions should be directed to Elmo Rietschle Service.

  • Never put the pump back into operation after automatic shut-off without finding and remedying the cause.
  • Table covers: machine switched off by motor protection switch; suction capacity insufficient; final pressure not reached; machine gets too hot; machine makes strange noise.
  • Remedies include checking mains voltage/frequency, motor terminal connection, motor protection switch setting, cleaning/replacing air filter, checking pipes for leaks, ensuring proper use, cleaning ventilation slots, cleaning working space and rotary piston.
  • Contact Elmo Rietschle Service for other malfunctions or those that cannot be eliminated.
pp. 33
Technical Data

Chapter 10 contains technical data; specific values are referenced throughout the manual (e.g., weight for bearing surface design, sound pressure level). The data sheet D 893 provides technical data and characteristic curves.

  • Technical data in chapter 10.
  • Data sheet D 893 contains technical data and characteristic curves.
  • Sound pressure level per EN ISO 3744 is given in chapter 10.

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Continuous operation is possible at any pressure between 700 mbar (abs.) and an inlet pressure of 60 mbar (abs.). p.16 ↗ Select pump for applications within this inlet pressure range; operation outside requires consultation with manufacturer. C-VLU 401, 501, 651
Pumping speed with free suction at 50 Hz: 380 m³/h (VLU 401), 495 m³/h (VLU 501), 600 m³/h (VLU 651). p.16 ↗ Use these values for sizing; actual pumping speed depends on intake pressure per data sheet D 893. C-VLU 401, 501, 651
Maximum permissible back pressure: +30 mbar. p.8 ↗ Exhaust line and any downstream equipment must not create more than +30 mbar back pressure; higher back pressure requires consultation. C-VLU 401, 501, 651
Ambient and inlet temperature must be between 5 °C and 40 °C. p.8 ↗ Install in locations where ambient and inlet temperatures remain within this range; outside range contact manufacturer. C-VLU 401, 501, 651
Machine may only be operated when set up horizontally with max. inclination 8° in all directions. p.17 ↗ Mount on a level, even floor; secure against tipping and falling. C-VLU 401, 501, 651
Cooling air inlets and outlets must be at least 30 cm away from adjacent walls. p.17 ↗ Maintain clearance to ensure sufficient cooling air flow and prevent recirculation of heated air. C-VLU 401, 501, 651
Provide at least 50 cm space around the machine for maintenance works. p.17 ↗ Layout installation to allow access to oil filling point, sight glass, oil drain and filters. C-VLU 401, 501, 651
Permissible voltage deviation ±5 % of nominal value; frequency deviation ±2 %. p.19 ↗ Verify mains supply quality before connection; deviations beyond these limits may cause loss of power or damage. C-VLU 401, 501, 651
AC motors with apparent output >1.7 kVA, three-phase motors >5.2 kVA, or motors with start currents >60 A are not designed for direct start on the network. p.19 ↗ Use star-delta starting, smooth starter or frequency converter for such motors to reduce mechanical load at start. C-VLU 401, 501, 651
Motors comply with DIN EN 60034, protection class IP 55 and insulation class F. p.19 ↗ Suitable for dusty and humid industrial environments within IP 55 rating; verify environmental conditions. C-VLU 401, 501, 651
Operation without pressure monitoring is not permitted; no pressure monitoring fitted at factory. p.20 ↗ Customer must install a pressure monitoring system that switches off the pump or brings it to a safe state if pressure falls below the minimum permissible final pressure on the rating plate. C-VLU 401, 501, 651
Permissible pressure deviation tolerance: ±5 % relative to nameplate data. p.20 ↗ Set pressure monitoring switch with consideration of this tolerance. C-VLU 401, 501, 651
Before shutdown longer than 2 hours or decommissioning, run the vacuum pump at 500 mbar (abs.) for at least 15–30 minutes with dry air. p.22 ↗ Prevents condensate and impurities from adhering to rotors and casing, which could prevent restart. C-VLU 401, 501, 651
Storage temperature: -20 °C to +70 °C; relative air humidity max. 80 %; store dust-free, dry, vibration-free, protected from sun radiation; do not store for more than 6 months. p.13 ↗ Follow storage conditions to avoid material damage; close openings air-tight. C-VLU 401, 501, 651
Output reduction is noticeable when installed at more than 1000 m above sea level. p.18 ↗ Contact manufacturer for high-altitude installations to account for reduced cooling and performance. C-VLU 401, 501, 651
XD model is suitable for conveying water-damp gases (water vapour) and has a condensate drain on the silencer. p.16 ↗ Select XD variant for moist gas applications; regularly discharge condensate. C-VLU 401 XD, 501 XD, 651 XD
Intake filter available with paper filter or polyester filter. p.16 ↗ Select filter type based on process gas and dust loading; protects machine from solids. C-VLU 401, 501, 651 (accessory)
Rotation direction check: start motor briefly (max. two seconds); when looking at the motor blower, it must rotate counter-clockwise. p.22 ↗ Verify correct rotation before continuous operation to avoid damage and injury. C-VLU 401, 501, 651
The vacuum pump does not have its own Emergency Stop or Emergency Off; this must be implemented by the operator. p.11 ↗ Integrate pump into the operator's protection concept with appropriate emergency stop devices. C-VLU 401, 501, 651
Surface temperatures on components may rise above 70 °C during operation. p.21 ↗ Do not touch hot surfaces; wear protective gloves if necessary; ensure hot parts are guarded. C-VLU 401, 501, 651

Faults & Troubleshooting

Code / Symptom Possible Cause Remedy Note
Machine is switched off by the motor protection switch p.32 ↗ Mains voltage/ Frequency does not correspond with the motor data Check by qualified electrician Chapter 5.5
Machine is switched off by the motor protection switch p.32 ↗ Connection to motor terminal board is not correct Check by qualified electrician Chapter 5.5
Machine is switched off by the motor protection switch p.32 ↗ Motor protection switch is not set correctly Check by qualified electrician Chapter 5.5
Motor protection switch is triggered too quickly p.32 ↗ Short excess current at start up Use a motor protection switch with an overload-dependent turn-off delay that considers the short excess current at start up (version with short circuit and overload trigger as per VDE 0660 Part 102 or IEC 60947-4-1)
Suction capacity is insufficient p.32 ↗ Air filter is polluted Clean/replace air filter Chapter 7.6, Chapter 7.9
Suction capacity is insufficient p.32 ↗ The inlet pipe is too long or too narrow Check the hose and/or the pipe Chapter 5.3
Suction capacity is insufficient p.32 ↗ Machine or system leaking Check the pipework and screw connections for leaks and check for tight fit Chapter 5.3
Final pressure (max. vacuum) is not reached p.32 ↗ Machine or system leaking Check the pipework and screw connections for leaks and check for tight fit Chapter 5.3
Final pressure (max. vacuum) is not reached p.32 ↗ Air filter is polluted Clean/replace air filter Chapter 7.6, Chapter 7.9
Machine gets too hot p.32 ↗ Ambient or inlet temperatures too high Ensure proper use Chapter 2.4
Machine gets too hot p.32 ↗ Cooling air supply is obstructed Check ambient conditions Chapter 5.1
Machine gets too hot p.32 ↗ Cooling air supply is obstructed Clean ventilation slots Chapter 7.4
The machine makes a strange noise p.32 ↗ Deposits on the rotary piston Clean the working space and the rotary piston Elmo Rietschle Service