Aún no hay foto disponible
Agilent Technologies Custom Gene Expression Microarray
Agilent Technologies Custom Gene Expression Microarray — Plataforma de microarrays de expresión génica.
Los microarrays personalizados de expresión génica son un consumible, no un instrumento: un conjunto de sondas definido por el usuario sobre la plataforma de oligos de 60-mer de Agilent, procesado con el protocolo de marcaje Low Input Quick Amp. Esta modificación se define por su ventana de bajo input — 10–200 ng de ARN total o 5 ng de ARN polyA — y por el esquema de dilución Spike Mix/Spike A/B que debe coincidir con el input inicial. Se utiliza para interrogar transcritos especificados por el usuario en hibridaciones de uno o dos colores.
Agilent Technologies Custom Microarrays Series — Model Comparison & Selection
| Modelo | Total rna input, ng | Total rna input highest listed, ng | Total rna input lowest listed, ng | Cdna synthesis incubation, °C | Cdna synthesis incubation time, hours | Crna elution volume, microliter |
|---|---|---|---|---|---|---|
| Custom Gene Expression Microarray Actual | 10...200 | 200 | 10 | 40 | 2 | 30 |
| Take gene expression to the next level, Custom Exon Microarrays | 25 | 100 | 25 | 40 | 2 | 30 |
Especificaciones completas
| Volumen de reconstitución del agente bloqueante 10× | 500 µL |
| Tiempo de incubación de síntesis de cDNA | 2 hours |
| Volumen de elución de cRNA | 30 µL |
| Centrifugación de purificación de cRNA | 13000 rpm |
| Tiempo de incubación de transcripción de cRNA | 2 hours |
| Tiempo de inactivación enzimática | 15 minutes |
| Tiempo de incubación de fragmentación | 30 minutes |
| Duración de hibridación | 17 hours |
| Volumen total de mezcla de hibridación | 250 µL |
| Velocidad del rotador de hibridación | 10 rpm |
| Tiempo de hibridación | 17 hours |
| Volumen de hibridación | 490 µL |
| Volumen máximo de muestra de RNA total | 2.3 µL |
| Volumen mínimo de dispensación de pipeta | 2 µL |
| Volumen de pipeteo | 2 µL |
| Entrada de mRNA poli A | 5 ng |
| Entrada de RNA poli A, mínimo indicado | 5 ng |
| Tiempo de desnaturalización de cebador/plantilla | 10 minutes |
| Rendimiento recomendado de cRNA | 5 µg |
| Tiempo de incubación térmica de la mezcla spike | 5 minutes |
| Volumen de mezcla spike por 100 ng de RNA total | 1 µL |
| Volumen de mezcla spike por reacción de marcaje | 2 µL |
| Cantidad inicial de RNA total | 25 ng |
| Tiempo requerido del paso 1 | 0.5 hours |
| Entrada de ARN total | 10...200 ng |
| Entrada de ARN total, valor máximo indicado | 200 ng |
| Entrada de ARN total, valor mínimo indicado | 10 ng |
| Volumen total | 3 |
| Concentración final de Triton X-102 en tampones de lavado | 0.005 % |
| Spike A Mix labeling dye mfr | 3 |
| Feature Extraction Software version for SpikeIns LogRatio Statistics mfr | 10.7.3 later |
| Starting total RNA input variants mfr | four different starting sample inputs inputs |
| Amplification factor total RNA to cRNA mfr | 100 fold |
| Minimum total RNA input for high quality data mfr | 10 ng |
| Total RNA plus spike-in volume limit mfr | 3.5 μL |
| Recommended specific activity mfr | 15 cRNA |
| Cyanine 3-labeled cRNA in fragmentation mix mfr | 600 ng |
| Microarray slide format mfr | 1 slide |
| Minimum total RNA for high quality data mfr | 10 ng |
| Maximum volume of total RNA plus diluted spike-in mfr | 3.5 μL |
| First spike dilution storage mfr | 2 months |
| Step 1 time required (Prepare Spike A Mix and Spike B) mfr | 0.5 hours |
| Step 2 time required (Prepare labeling reaction) mfr | 5.5 hours |
| Step 3 time required (Purify labeled/amplified RNA) mfr | 0.5 hours |
| Cyanine 3-labeled cRNA per hybridization mfr | 300 ng |
| Agilent Microarray Scanner mfr | 4900 BA |
| Hybridization gasket slides 1 microarray/slide, 5 slides/box mfr | 2534 |
| Hybridization gasket slides 2 microarrays/slide, 5 slides/box mfr | 2534 |
| Hybridization gasket slides 4 microarrays/slide, 5 slides/box mfr | 2534 |
| Hybridization gasket slides 8 microarrays/slide, 5 slides/box mfr | 2534 |
| G4852B mfr | 3 Kit |
| G4858A-074809 mfr | 3 Microarray |
| G4852A mfr | 3 Kit |
| G4858A-028005 mfr | 3 Microarray |
| G4846A mfr | 4 Kit |
| G2519F-026655 mfr | 4 Microarray |
| RNA 6000 Nano Assay Kit (RNA Series II Kit) mfr | 5067 |
| Quick Amp Labeling Kit, One-Color mfr | 5190 |
| Stabilization and Drying Solution* mfr | 5185 |
| Ozone-Barrier Slide Cover* mfr | 2505 |
| Absolutely RNA Nanoprep Kit mfr | 400753 |
| slide box mfr | 07201629 |
| acetonitrile mfr | 271004 L |
| sulfolane mfr | 22209 |
| thermal cycler mfr | 96 tubes |
| G4851C mfr | 3 Kit |
| G4858A-072363 mfr | 3 Microarray |
| G4851B mfr | 3 Kit |
| G4858A-039494 mfr | 3 Microarray |
| G4851A mfr | 3 Kit |
| G4858A-028004 mfr | 3 Microarray |
| G4845A mfr | 4 Kit |
| G2519F-026652 mfr | 4 Microarray |
| Hybridization oven rotator for Agilent Microarray Hybridization Chambers mfr | 2530 |
| nuclease-free 1.5 mL microfuge tube mfr | 12400 equivalent |
| magnetic stir bar (×2) mfr | 401435 equivalent |
| magnetic stir plate (×2) mfr | 6795 equivalent |
| circulating water baths or heat blocks set to 37°C, 40°C, 60°C, 65°C, 70°C, and 80°C mfr | 6795 equivalent |
| microcentrifuge mfr | 5417 equivalent |
| sterile storage bottle mfr | 455 equivalent |
| spectrophotometer mfr | -1000 equivalent |
| micropipettor mfr | -10 equivalent |
| slide-staining dish, with slide rack (×3) mfr | 121 equivalent |
| RNA 6000 Nano LabChip Kit mfr | 5067 |
| RNA 6000 Pico LabChip Kit mfr | 5067 |
| Universal Human Reference RNA mfr | 740000 |
| Universal Mouse Reference RNA mfr | 740100 |
| Universal Rat Reference RNA mfr | 740200 |
| Low Input Quick Amp Labeling Kit, One-Color mfr | 5190 |
| RNA Spike-In Kit, One-Color mfr | 5188 |
| Gene Expression Hybridization Kit mfr | 5188 |
| Gene Expression Wash Buffer Kit mfr | 5188 |
| DNase/RNase-free distilled water mfr | 10977 |
| RNeasy Mini Kit mfr | 74104 |
| ethanol (95% to 100% molecular biology grade) mfr | 7023 ML |
| amplification factor mfr | 100 fold |
| first dilution storage duration mfr | 2 months |
| ozone level threshold mfr | 50 ppb |
| scan resolution mfr | 5 μm |
| Feature Extraction minimum version for eArray download mfr | 10.7 |
| Quick Amp Labeling Kit, Two-Color mfr | 5190 |
| Low Input Quick Amp Labeling Kit, Two-Color mfr | 5190 |
| RNA Spike-In Kit, Two-Color mfr | 5188 |
| amplification fold mfr | 100 fold |
| Triton X-102 addition volume mfr | 2 mL |
| acetonitrile wash time mfr | 10 seconds |
| stabilization and drying wash time mfr | 30 seconds |
| G4832A mfr | 3 Kit |
| G4857A-028679 mfr | 3 Microarray |
| G4848A mfr | 3 Kit |
| G4856A-028680 mfr | 3 Microarray |
| vacuum concentrator mfr | 120 equivalent |
| Low Input Quick Amp WT Labeling Kit, Two-Color mfr | 5190 |
| Spectrophotometer mfr | -1000 equivalent |
| Affinity Script RNase Block Mix (violet cap) mfr | 1.2 |
| minimum labeled cRNA per microarray mfr | 1.65 μg |
| ozone robustness level mfr | 5 ppb |
| thermocycler program 1 time mfr | 10 minutes |
| thermocycler program 2 time mfr | 2 hours |
| thermocycler program 2 second time mfr | 15 minutes |
| thermocycler hold time mfr | 5 minutes |
| cRNA size range lower bound mfr | 200 nucleotides |
| Hybridization Chamber, stainless mfr | 2534 A |
| Spike Mix first serial dilution mfr | 1 |
| Spike Mix second serial dilution mfr | 1 |
| Spike Mix third serial dilution mfr | 1 |
| Spike A Mix serial dilution (first) mfr | 1 |
| Spike A Mix serial dilution (second) mfr | 1 |
| Spike A Mix serial dilution (third) mfr | 1 |
| Spike A Mix serial dilution (fourth) mfr | 1 |
| Spike mix serial dilution first mfr | 1 |
| Spike mix serial dilution second mfr | 1 |
| Spike mix serial dilution third mfr | 1 |
| Spike mix serial dilution fourth mfr | 1 |
| Serial dilution first mfr | 1 |
| Serial dilution second mfr | 1 |
| Serial dilution third mfr | 1 |
| Serial dilution fourth mfr | 1 |
| Incubación de síntesis de cDNA | 40 °C |
| Temperatura de incubación de transcripción de cRNA | 40 °C |
| Temperatura de inactivación enzimática | 70 °C |
| Temperatura de precalentamiento del tampón de primera hebra | 80 °C |
| Incubación de fragmentación | 60 °C |
| Temperatura de hibridación | 65 °C |
| Temperatura de incubación térmica de la mezcla spike | 37 °C |
| Temperatura de calentamiento de la mezcla spike | 37 °C |
| Temperatura de almacenamiento del agente bloqueante 10× | -20 °C |
| Temperatura de almacenamiento de ARN total >100 ng/µl | -80 °C |
| Temperatura de desnaturalización del cebador T7 | 65 °C |
| Temperatura de precalentamiento del tampón de lavado 2 | 37 °C |
| AffinityScript inactivation incubation mfr | 70 °C |
| G4122F mfr | 4 K |
| G2519F-014868 mfr | 4 K |
| G2519F-021169 mfr | 4 K |
| G2519F-021623 mfr | 4 K |
| G2519F-023647 mfr | 4 K |
| G2519F-022520 mfr | 4 K |
| G2519F-021193 mfr | 4 K |
| G2519F-020186 mfr | 4 K |
| G2519F-026441 mfr | 4 K |
| G2519F-022523 mfr | 4 K |
| G2519F-021791 mfr | 4 K |
| G2519F-021322 mfr | 4 K |
| G2519F-015060 mfr | 4 K |
| G2519F-022524 mfr | 4 K |
| G2519F-020449 mfr | 4 K |
| G2519F-026440 mfr | 4 K |
| G2519F-026806 mfr | 4 K |
| G2519F-020908 mfr | 4 K |
| G2519F-015241 mfr | 4 K |
| G2519F-020938 mfr | 4 K |
| G4813A-019921 mfr | 8 K |
| G2519F-021113 mfr | 4 K |
| G2519F-022297 mfr | 4 K |
| G4813A-016322 mfr | 8 K |
| G2519F-026437 mfr | 4 K |
Descripción
En qué consiste esta modificación
- Un microarray diseñado a medida: el contenido de sondas es definido por el usuario, por lo que el array en sí no lleva una lista de genes fija; los arrays de exones hermanos y los arrays de expresión génica de levadura son conjuntos de contenido prediseñado, y son la elección correcta cuando un catálogo estándar cubre los objetivos.
- La química de procesamiento es el protocolo de marcaje Low Input Quick Amp (one-color v6.9, two-color v6.9.1, exon two-color v2.0), que fija la ventana de entrada y el esquema de spike-in.
Ventana de entrada y comportamiento del spike-in
- La entrada de ARN total abarca desde 10 ng (el valor más bajo listado) hasta 200 ng (el valor más alto listado); la entrada de ARN poliA desciende hasta 5 ng.
- El Spike Mix se prepara como una serie de dilución seriada de cuatro pasos y se añade a 2 µL por reacción de marcaje; el Spike Mix se incuba en calor a 37 °C durante 5 minutos antes de su uso.
- El protocolo de dos colores utiliza dos mezclas de spike separadas: Spike A lleva el colorante 3 y Spike B lleva el colorante 5, cada una con su propia serie de dilución de cuatro pasos.
- El protocolo de exones de dos colores define esquemas de dilución de spike para entradas de ARN total de 25, 50 y 100 ng; la cantidad inicial de ARN total se indica como 100 ng en los datos de fábrica, y se listan cuatro entradas de muestra iniciales diferentes como variantes — el esquema de dilución debe seleccionarse para coincidir con la entrada real, no asumirse.
Manipulación y flujo de trabajo
- El volumen mínimo de dispensación con pipeta es 2 µL, lo que fija el límite práctico para todas las transferencias de reactivos en los pasos de spike y marcaje.
- El paso 1 (preparación de la mezcla de spike) requiere 0.5 horas.
- En el procedimiento se especifica una temperatura de equilibrado del baño de agua de 80 °C.
- La extracción de datos se realiza con el software Agilent Feature Extraction; las estadísticas SpikeIns LogRatio requieren la versión 10.7.3 o posterior.
Integration & Operating Notes
Selection & Integration Q&A
Elija esta matriz cuando los objetivos sean transcritos definidos por el usuario y la entrada esté en la ventana de 10–200 ng de ARN total o 5 ng de poliA bajo el marcaje Low Input Quick Amp. Elija la matriz de exones personalizada cuando se requiera resolución a nivel de exón, y la matriz de levadura cuando el organismo sea S. cerevisiae y un conjunto de contenido prediseñado sea suficiente.
El flujo de trabajo debe ejecutar el protocolo de marcaje Low Input Quick Amp con una mezcla de spike ajustada a la entrada (Spike Mix para un color; colorante Spike A 3 y colorante Spike B 5 para dos colores), dispensada a 2 µL por reacción con pipetas verificadas a 2 µL. La extracción de datos debe usar Feature Extraction Software 10.7.3 o posterior para obtener las estadísticas SpikeIns LogRatio.
La entrada de ARN total debe mantenerse entre 10 y 200 ng (ARN poliA hasta 5 ng); el esquema de dilución de spike se elige para la entrada real (los esquemas de 25, 50 o 100 ng están definidos en el protocolo de dos colores para exones). Spike Mix se incuba en calor a 37 °C durante 5 minutos, el Paso 1 toma 0.5 horas y se especifica una equilibración en baño de agua a 80 °C.
La matriz es un consumible: los reactivos de marcaje, las mezclas de spike y el Feature Extraction Software son elementos separados, y no aplican cables ni accesorios. Programe 0.5 horas para la preparación de spike del Paso 1, verifique las pipetas al volumen mínimo de dispensación de 2 µL y confirme que el software de extracción esté en 10.7.3 o posterior antes de la ejecución.