Induztr
Résumé technique Visionneuse de documents Modèles associés

Technical Data Sheet — L-BV5 2BV5111 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Familia de bombas de vacío de anillo líquido L-BV5, hoja de datos del modelo 2BV5 111. Abarca variantes de tensión de 50 Hz y 60 Hz, variantes de material de fundición (K) y acero inoxidable (H), y bombas de vacío de categoría 2G ATEX disponibles bajo pedido.

Technical Data

Parameter Value Condition
Suction capacity 111 m³/h p.2 ↗ 2BV5 111, 50 Hz
Ultimate pressure 33 mbar abs. p.1 ↗ 97 % vacuum
Cavitation-free operation down to 80 mbar abs. p.1 ↗
Motor power 5,5 kW p.2 ↗ 2BV5 111, 50 Hz
Motor power 7,2 kW p.2 ↗ 2BV5 111, 60 Hz
Voltage 190-210 V p.2 ↗ 50 Hz, Δ
Voltage 380-420 V p.2 ↗ 50 Hz, Y
Voltage 220-240 V p.2 ↗ 60 Hz, Δ
Voltage 440-480 V p.2 ↗ 60 Hz, Y
Current 29,9 A p.2 ↗ 50 Hz, 190-210 V Δ
Current 16,5 A p.2 ↗ 50 Hz, 380-420 V Y
Current 28,5 A p.2 ↗ 60 Hz, 220-240 V Δ
Current 14,3 A p.2 ↗ 60 Hz, 440-480 V Y
Service factor 1,36 - p.2 ↗ 50 Hz
Service factor 1,19 - p.2 ↗ 60 Hz
Efficiency class IE3 - p.2 ↗ 50 Hz
Sound pressure level 67 dB(A) p.2 ↗ 50 Hz, cast iron K
Sound pressure level 72 dB(A) p.2 ↗ 60 Hz, cast iron K
Weight 119 kg p.2 ↗ 50 Hz, cast iron K
Weight 124 kg p.2 ↗ 60 Hz, cast iron K
Protection rating IP55 - p.1 ↗
Insulation class F - p.2 ↗
Max. additional water carry-over 3,3 m³/h p.2 ↗ 50 Hz and 60 Hz
Max. back pressure 1300 mbar abs. p.2 ↗ 50 Hz and 60 Hz

Operating Limits

  • Min. inlet pressure (ultimate pressure): 33 mbar abs. p.1 ↗
  • Cavitation-free operation down to: 80 mbar abs. p.1 ↗
  • Max. additional water carry-over: 3,3 m³/h p.2 ↗
  • Max. back pressure: 1300 mbar abs. p.2 ↗
  • Protection rating: IP55 p.1 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BV5 Product family: liquid ring vacuum pump L-BV5
5-7 p.2 ↗ 111 Size designation (nominal suction capacity 111 m³/h)
field after 2BV5…- p.2 ↗ K / C / H Material variant: K = cast iron with ceramic coating, C = cast iron with CrNi steel port plate, H = CrNi steel
voltage field p.2 ↗ 1 / 6 / 7 Voltage/frequency variant: 1 = 190-210 V Δ / 380-420 V Y 50 Hz, 6 = 220-240 V Δ / 440-480 V Y 60 Hz, 7 = 440-480 V Δ 60 Hz