Induztr
Engineering Digest Document Viewer Related Models

Operating Instructions — VSI 301 vacuum pump (BA 834-EN, ed. 1.3 14.10.2021, EN)

Technical Reference Summary

Covered Models & Document Scope

Covers screw vacuum pump S-VSI 301 and S-VSI 301 with frequency converter (variants Fxxx). Variants include standard IV, corrosion-protected XD, and FU (frequency converter). Cooling variants: continuous flow cooling (standard), circulation cooling with water-air heat exchanger, and circulation cooling with water-water heat exchanger. Optional sealing gas unit and gas ballast valve (accessory IV).

Section-by-Section Technical Breakdown

pp. 15-20
Product Overview and Functioning

Describes the S-VSI 301 twin-screw vacuum pump construction, including continuous flow cooling, circulation cooling with water-air or water-water heat exchangers, and frequency converter variants. Includes component identification, data plate layout, and functional description of the dry-running screw rotors, gearbox lubrication, and sealing system.

  • Twin-screw vacuum pump with contactless dry-running rotors synchronized by an oil-lubricated gear pair.
  • Gearbox and compression chamber separated by special seals; atmospherically ventilated area can be loaded with sealing gas (special version).
  • Driven by standard flanged three-phase motor via elastomer coupling.
  • Frequency converter mounted on motor enables stepless speed control.
  • XD variation has corrosion-protective coating.
  • Data plate includes type/size, serial number, year, item number, speed, motor output, operating mode, suction capacity, final pressure.
pp. 21-23
Cooling of the Machine

Details the three cooling configurations: continuous flow cooling (standard), circulation cooling with water-air heat exchanger, and circulation cooling with water-water heat exchanger. Each system includes temperature monitoring, liquid level monitoring, and safety devices with specified setpoints and voltages.

  • Continuous flow cooling: fresh water flows through double-walled compressor housing; includes solenoid valve (24 V DC, normally closed), temperature control (Tmax = 60 °C), safety valve (>6 bar), and dirt trap.
  • Circulation cooling water-air: filled once with water-Glysantin mixture, circulated by pump (230 V AC), air-cooled by fan (230 V AC); pressure compensation container pmax = 1.2 bar.
  • Circulation cooling water-water: similar to water-air but uses water-cooled heat plate exchanger.
  • Temperature control default Tmax = 60 °C for all cooling types.
  • Liquid level monitor and manometer monitor filling level; factory filling pressure pmax = 1.2 bar for circulation systems.
pp. 24
Pump with Sealing Gas Unit

Describes the optional sealing gas unit used to prevent gearbox contamination by aggressive media. Includes safety valve, sealing gas flow meter, and sealing gas valve with specified pressure and flow limits.

  • Sealing gas connection G 1/4.
  • Safety valve protects from incorrect operating pressure > 0.3 bar.
  • Sealing gas flow meter indicates consumption; maximum sealing gas consumption 260 Nl/h.
  • Sealing gas valve controls operating pressure; maximum permissible operating pressure 0.2 bar.
  • Recommended for very short cycle times to avoid condensation and premature gear damage.
pp. 25-31
Installation

Covers preparation of installation, mechanical installation, pipe connections, cooling water connection for each cooling variant, lubricating oil check, electrical connection (motor, sensors, circulation pump, fan), and optional sealing gas connection.

  • Machine must be freely accessible from all sides; ventilation grids and holes must not be closed.
  • Sufficient space required for pipe installation/removal and maintenance.
  • No external vibration.
  • Cooling water connections differ by cooling type: continuous flow (G 1/2 inlet/outlet), water-air heat exchanger, water-water heat exchanger.
  • Electrical connection: motor without frequency converter, motor with frequency converter, sensors, circulation pump, fan.
  • Sealing gas connection optional; pump with or without sealing gas device.
pp. 32-34
Commissioning and Decommissioning

Describes start-up procedures including installation control and rotation direction check, operation including draining condensate, decommissioning, storing, and recommissioning.

  • Installation control before start-up.
  • Check rotation direction.
  • Drain condensate during operation.
  • Shutting down and storing the machine.
  • Recommissioning procedure.
pp. 35-43
Maintenance and Repair

Covers maintenance table, preliminary maintenance work, cleaning the vacuum pump, oil change and level check, air filter maintenance (intake and gas ballast valve filter), cooling system maintenance (continuous and circulation cooling, heat exchanger cleaning), motor and coupling, frequency converter, repair/service, and spare parts.

  • Maintenance table specifies intervals.
  • Oil change and oil level check procedures.
  • Intake air filter and gas ballast valve filter (Accessory IV) maintenance.
  • Cooling system maintenance: continuous cooling, circulation cooling water check/refill/replace, cleaning water-air heat exchanger, water-to-water heat exchanger.
  • Motor and coupling maintenance.
  • Frequency converter maintenance.
  • Spare parts available per spare parts list E 834.
pp. 44-45
Faults

Fault table listing malfunctions, causes, and elimination measures. Includes symptoms such as machine overheating and strange noise, with references to relevant chapters.

  • Machine gets too hot: causes include high ambient/inlet temperature, obstructed cooling air, obstructed cooling water system, insufficient cooling water, low cooling water pressure, hot cooling water inflow.
  • Machine makes a strange noise: cause deposits on rotors; remedy clean working space and rotors or contact Elmo Rietschle Service.
  • For further or unresolved faults, contact Elmo Rietschle Service.
pp. 47-50
Technical Data

Technical data for continuous flow cooling (standard), circulation cooling with water-air heat exchanger, circulation cooling with water-water heat exchanger, and cooling water consumption for water-water heat exchanger.

  • Data provided per cooling variant.
  • Includes cooling water consumption for water-water heat exchanger.

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Ambient and inlet temperature range: 5 to 40 °C. p.9 ↗ Operation outside this range requires consultation with manufacturer; may affect cooling and motor winding temperature. S-VSI 301 all variants
Maximum back pressure limits: S-VSI 7.5 kW > +200 mbar; S-VSI 5.5 kW > +30 mbar. p.9 ↗ Exceeding these back pressures is an inadmissible operating mode and may damage the pump. S-VSI 301 7.5 kW and 5.5 kW variants
Inlet pressure range for continuous vacuum: 0.08 - 1000 mbar (abs). p.20 ↗ Suitable for evacuation of closed systems or continuous vacuum within this range. S-VSI 301 all variants
Maximum suction capacity with unrestricted suction: 300 m³/h at 50 Hz. p.20 ↗ Performance depends on inlet pressure; refer to data sheets D 834 or D 834-FU for curves. S-VSI 301 all variants
S-VSI 301 with 5.5 kW motor may only be operated in continuous operation S1. p.20 ↗ Intermittent or frequent switching may exceed motor winding and bearing temperature limits. S-VSI 301 5.5 kW
Temperature control default setpoint: Tmax = 60 °C for cooling water. p.21 ↗ Cooling water temperature is monitored; exceeding 60 °C may trigger alarm or shutdown. All cooling variants
Safety valve for continuous flow cooling opens at cooling water pressure > 6 bar. p.21 ↗ Protects cooling circuit from overpressure; ensure supply pressure does not exceed 6 bar. Continuous flow cooling (standard)
Solenoid valve control voltage: 24 V DC, normally closed. p.21 ↗ Electrical supply must provide 24 V DC; valve closes on power loss, stopping cooling water flow. Continuous flow cooling (standard)
Circulation cooling system pressure: pmax = 1.2 bar (filling pressure and system pressure). p.22 ↗ Pressure compensation container controls operating pressure; do not exceed 1.2 bar. Circulation cooling water-air and water-water
Circulation pump and fan voltage: 230 V AC. p.22 ↗ Electrical supply must provide 230 V AC for these components. Circulation cooling variants
Sealing gas maximum consumption: 260 Nl/h. p.24 ↗ Size sealing gas supply accordingly; flow meter indicates actual consumption. Pump with sealing gas unit
Sealing gas maximum permissible operating pressure: 0.2 bar. p.24 ↗ Sealing gas valve controls pressure; safety valve protects at >0.3 bar. Pump with sealing gas unit
Storage temperature range: -10 °C to +60 °C; relative humidity max 80%; storage not exceeding 6 months. p.14 ↗ Store in dry, dust-free, vibration-free, sun-protected area; seal openings airtight. S-VSI 301 all variants
Maximum inclination during transport: 10° in all directions. p.13 ↗ Ensure horizontal base during transport to prevent tipping and damage. S-VSI 301 all variants
Vacuum connection: G 2; exhaust air outlet: G 2; cooling water inlet/outlet: G 1/2; condensate drain: G 1/2; sealing gas connection: G 1/4. p.15 ↗ Pipe and fitting selection must match these thread sizes. S-VSI 301 all variants
Frequent switching (approx. 10 times per hour) or high ambient/inlet temperatures may exceed motor winding and bearing temperature limits. p.20 ↗ Contact manufacturer for such operating conditions; may require derating or additional cooling. S-VSI 301 all variants
If installed in open air, unit must be protected from environmental influences (e.g., protective roof). p.20 ↗ Outdoor installation requires additional weather protection. S-VSI 301 all variants
Machine does not have its own Emergency Stop or Emergency Off; must be implemented by user. p.12 ↗ Integrate machine into user's safety plan with appropriate emergency stop devices. S-VSI 301 all variants

Faults & Troubleshooting

Code / Symptom Possible Cause Remedy Note
Machine gets too hot p.45 ↗ Ambient or inlet temperatures too high Ensure proper use Chapter 2.4
Machine gets too hot p.45 ↗ Cooling air supply is obstructed Check ambient conditions Chapter 5.1
Machine gets too hot p.45 ↗ Cooling air supply is obstructed Clean the cooling ribs Chapter 7.7
Machine gets too hot p.45 ↗ The cooling water system is obstructed Check the cooling water system and the inlet pipes Chapter 7.2
Machine gets too hot p.45 ↗ Not enough cooling water Observe cooling water consumption Chapter 10
Machine gets too hot p.45 ↗ Cooling water pressure too low Refill cooling water Chapter 7.7
Machine gets too hot p.45 ↗ Cooling water inflow is too hot Observe the max. inlet temperature Chapter 10
The machine makes a strange noise p.45 ↗ Deposits on the rotors Clean the working space and the rotors Elmo Rietschle Service