Operating Instructions — vacuum pump (BA 892-EN, ed. 1.1 18.02.2025, EN)

Technical Reference Summary

Covered Models & Document Scope

Covers the contact-free running claw vacuum pump C-VLU 301 in standard CD version and XD version with corrosion-protective coating for moist gases/water vapour. Includes motor/pump combination ready for connection, optional intake filter (paper or polyester), and optional flushing device. Document BA 892-EN, edition 1.1, 18.02.2025.

Section-by-Section Technical Breakdown

pp. 14-16
Product Overview and Functioning

Describes the C-VLU 301 as a double-shaft rotary piston vacuum pump with contact-free rolling claws, gear-synchronised rotors, oil-lubricated gearbox and bearings, and a compression chamber separated from the gearbox by special seals. The pump has an inlet flange with integral non-return valve, exhaust silencer, mesh intake filter, insulation hood and drum-fan cooling. It is driven by a flanged three-phase standard motor via a coupling.

  • Double-shaft rotary piston (claw) principle, contact-free and dry running
  • Counter-rotating claw rotors synchronised by an oil-lubricated gear pair
  • Integral non-return valve prevents ventilation of the evacuated system after stop
  • Cooling by drum fan drawing fresh air through cooling air inlet and discharging heated air at cooling air outlet
  • XD model has corrosion-protective coating and condensate drain
  • Hot surfaces > 70 °C are marked
pp. 15
Data Plate

The data plate contains model/size, serial number, year of construction, data matrix barcode, article number, speed 50/60 Hz, motor output 50/60 Hz, operating mode, pumping capacity 50/60 Hz and final pressure (abs.) 50/60 Hz. The barcode encodes material number, production order and serial number.

  • Example data plate: C-VLU 301 CD (01), 30.00/30.00 mbar (abs), 265.0/320.0 m³/h, 7.50/9.00 kW, 2935/3530 /min, S1 100%
  • Barcode encodes material number (MA), production order (PR) and serial number (SC)
  • Minimum permissible final pressure is specified on the rating plate
pp. 16
Fields of Application

The C-VLU 301 can be operated continuously at any pressure between 700 mbar (abs.) and an inlet pressure of 30 mbar (abs.). Pumping capacity with unrestricted suction is 265 m³/h at 50 Hz. The XD design is suitable for water-damp gases. Frequent switching or high ambient/inlet temperatures may exceed motor winding and bearing temperature limits.

  • Continuous operation between 700 mbar (abs.) and 30 mbar (abs.) inlet pressure
  • Pumping capacity 265 m³/h at 50 Hz with unrestricted suction
  • XD design suitable for conveying water-damp gases (water vapour)
  • Frequent switching (approx. 10 times per hour) or high temperatures may exceed motor winding and bearing limits
  • Outdoor installation requires protection from environmental influences (e.g. protective roof)
pp. 17-21
Installation

Covers preparation, mechanical installation, pipe connection, oil check, electrical connection, pressure monitoring and flushing device connection. The machine must be installed horizontally with max. 8° inclination, secured against tipping, with sufficient space and cooling air clearance. Electrical installation must be by a qualified electrician per EN 60204, with motor protection switch and main switch provided by the user.

  • Max. inclination 8° in all directions; floor must be plane and even
  • Maintain at least 50 cm around the machine for maintenance
  • Cooling air inlets/outlets at least 30 cm from adjacent walls
  • Ambient temperature min. +5 °C, max. +40 °C
  • Maximum permissible back pressure +30 mbar
  • Only screw in pipes by hand; use flexible connections if necessary
  • Motor protection switch and main switch must be provided by the operating company
  • Pressure monitoring on inlet side is mandatory; operation without pressure monitoring is not permitted
  • Flush valve connection: G 3/8
pp. 22-24
Commissioning and Decommissioning

Start-up requires an installation check and rotation direction check. The machine may only be switched on again after it has completely stopped. Operation requires sufficient cooling air. Decommissioning, storage and recommissioning procedures are described.

  • Installation check includes leak tightness, screw/flange tightness, electrical compliance, oil level and ventilation
  • Check rotation direction clockwise using a phase sequence indicator; keep 1 m distance from inlet/outlet
  • Start motor briefly (max. two seconds) to check rotation direction
  • Machine may only be restarted after it stands still
  • Operation only with sufficient cooling air quantity
pp. 25-32
Maintenance and Repair

Covers maintenance table, cleaning, lubricating oil check/refill and oil change, air filter (mesh filter, filter silencer, optional intake filter), motor and coupling, repair/service and spare parts. Maintenance intervals and procedures are specified.

  • Check oil level at oil sight glass and top up if necessary
  • Oil change procedure described
  • Mesh filter and filter silencer maintenance
  • Optional intake filter with paper or polyester filter element
  • Motor and coupling maintenance
  • Spare parts available from Gardner Denver Schopfheim GmbH
pp. 33
Errors

Table of malfunctions with causes and elimination measures. Covers motor protection switch tripping, insufficient suction capacity, final pressure not reached, overheating and strange noise. Includes references to relevant chapters and Elmo Rietschle Service.

  • Never put the pump back into operation after automatic shut-off without finding and remedying the cause
  • Motor protection switch must be set correctly and have overload-dependent turn-off delay
  • Air filter pollution reduces suction capacity and final pressure
  • Leaks in machine or system prevent reaching final pressure
  • Overheating caused by high ambient/inlet temperatures or obstructed cooling air
  • Strange noise from deposits on rotary piston requires cleaning or Elmo Rietschle Service
pp. 35
Technical Data

Technical data section referenced for weight, sound pressure level and other performance data. The data plate example provides key values: final pressure 30.00/30.00 mbar (abs), pumping capacity 265.0/320.0 m³/h, motor output 7.50/9.00 kW, speed 2935/3530 /min at 50/60 Hz.

  • Final pressure (abs.) 30.00 mbar at 50 Hz and 60 Hz (example data plate)
  • Pumping capacity 265.0 m³/h at 50 Hz, 320.0 m³/h at 60 Hz
  • Motor output 7.50 kW at 50 Hz, 9.00 kW at 60 Hz
  • Speed 2935 /min at 50 Hz, 3530 /min at 60 Hz
  • Operating mode S1 100%
  • Sound pressure level per EN ISO 3744 (see chapter 10)

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Permissible ambient and inlet temperature range is 5 to 40 °C. p.8 ↗ Operation outside this range requires consultation with the manufacturer; ensure installation room ventilation and cooling air supply. C-VLU 301 all variants
Maximum permissible back pressure is +30 mbar. p.8 ↗ Exhaust air opening must not be closed or restricted; do not install blocking devices; prevent liquid accumulation in exhaust line. C-VLU 301 all variants
Continuous operation possible at any pressure between 700 mbar (abs.) and 30 mbar (abs.) inlet pressure. p.16 ↗ Select pump for applications within this pressure range; minimum permissible final pressure is on rating plate. C-VLU 301 all variants
Pumping capacity with unrestricted suction is 265 m³/h at 50 Hz. p.16 ↗ Use data sheet D 892 for pumping capacity dependency on suction pressure. C-VLU 301 CD/XD
Motor electrical data: 7.50 kW at 50 Hz, 9.00 kW at 60 Hz; speed 2935 /min at 50 Hz, 3530 /min at 60 Hz; operating mode S1 100%. p.15 ↗ Verify mains voltage and frequency match motor data plate; permissible voltage deviation ±5%, frequency deviation ±2%. C-VLU 301 example data plate
Final pressure (abs.) 30.00 mbar at 50 Hz and 60 Hz (example data plate). p.15 ↗ Pressure monitoring must be installed to prevent operation below minimum permissible final pressure; permissible tolerance ±5% pressure deviation relative to nameplate data. C-VLU 301 example data plate
Motors comply with DIN EN 60034, protection class IP 55, insulation class F. p.19 ↗ Suitable for dusty/damp environments within IP55 limits; connection diagram in terminal box. C-VLU 301 all variants
Machines with AC motors >1.7 kVA or three-phase motors >5.2 kVA, or start currents >60 A, are not designed for direct start on the network. p.19 ↗ Use star-delta starting, soft starter or frequency converter; reduce mechanical load during high starting torques. C-VLU 301 all variants
Maximum inclination during installation is 8° in all directions; machine must be set up horizontally. p.17 ↗ Ensure plane and even floor; secure against tipping and falling; bearing surface must carry machine weight. C-VLU 301 all variants
Cooling air inlets and outlets must be at least 30 cm away from adjacent walls; cooling air coming out must not be sucked in again. p.17 ↗ Prevent overheating; ensure good aeration and venting of installation room. C-VLU 301 all variants
Provide at least 50 cm space around the machine for maintenance works. p.17 ↗ Ensure oil filling point, oil sight glass and oil drain are easily accessible. C-VLU 301 all variants
Flush valve connection is G 3/8. p.20 ↗ Connect flush valve to customer's flushing agent supply; monitor motor current during rinsing. C-VLU 301 with flushing device
Recommended flushing process: operate 3 minutes with suction valve closed and snifting valve open; open flush valve 4 seconds (flush cycle); close 10 seconds (flush pause); repeat as required; operate 15 minutes after final flushing to remove residual moisture. p.21 ↗ Integrate rinsing control into customer's control system; optimize duration and frequency on site. C-VLU 301 with flushing device
Storage temperature range -20 °C to +70 °C; relative air humidity max. 80%; store dust-free, dry, vibration-free, protected from sun radiation; close openings air-tight; do not store more than 6 months. p.13 ↗ Follow storage guidelines I 100 and I 150; improper storage can damage machine. C-VLU 301 all variants
Output reduction noticeable when installed at more than 1000 m above sea level. p.18 ↗ Contact manufacturer for high-altitude installations. C-VLU 301 all variants
Use motor protection circuit breakers with delayed switch off due to possible temporary excess current when starting under cold conditions. p.19 ↗ Select overload-dependent turn-off delay considering short excess current at start-up (VDE 0660 Part 102 or IEC 60947-4-1). C-VLU 301 all variants
Pressure monitoring on inlet side is mandatory; operation without pressure monitoring is not permitted. p.20 ↗ If machine supplied without pressure monitoring, operator must install pressure monitor and switch off pump or bring to safe state if pressure falls below minimum permissible final pressure. C-VLU 301 all variants
The vacuum pump does not have its own Emergency Stop or Emergency Off. p.11 ↗ Operator must implement Emergency Stop/Off by integrating pump into their protection concept. C-VLU 301 all variants
Standard model suitable for non-explosive, non-flammable, non-aggressive, non-toxic, dry gases and gas-air mixtures; XD model additionally suitable for moist gases and water vapour. p.8 ↗ Select XD variant for water vapour or moist gas applications; standard model not suitable for water vapour. C-VLU 301 CD vs XD
Intake filter available with paper filter or polyester filter element. p.16 ↗ Install appropriate intake filter on suction side to protect machine from dust and solids in process gas. C-VLU 301 with optional intake filter

Faults & Troubleshooting

Code / Symptom Possible Cause Remedy Note
Machine is switched off by the motor protection switch p.33 ↗ Mains voltage/ Frequency does not correspond with the motor data Check by qualified electrician Chapter 5.5
Machine is switched off by the motor protection switch p.33 ↗ Connection to motor terminal board is not correct Check by qualified electrician Chapter 5.5
Machine is switched off by the motor protection switch p.33 ↗ Motor protection switch is not set correctly Check by qualified electrician Chapter 5.5
Motor protection switch is triggered too quickly p.33 ↗ Motor protection switch is triggered too quickly Use a motor protection switch with an overload-dependent turn-off delay that considers the short excess current at start up (version with short circuit and overload trigger as per VDE 0660 Part 102 or IEC 60947-4-1)
Suction capacity is insufficient p.33 ↗ Air filter is polluted Clean/replace air filter Chapter 7.6, Chapter 7.9
Suction capacity is insufficient p.33 ↗ The inlet pipe is too long or too narrow Check the hose and/or the pipe Chapter 5.3
Suction capacity is insufficient p.33 ↗ Machine or system leaking Check the pipework and screw connections for leaks and check for tight fit Chapter 5.3
Final pressure (max. vacuum) is not reached p.33 ↗ Machine or system leaking Check the pipework and screw connections for leaks and check for tight fit Chapter 5.3
Final pressure (max. vacuum) is not reached p.33 ↗ Air filter is polluted Clean/replace air filter Chapter 7.6, Chapter 7.9
Machine gets too hot p.33 ↗ Ambient or inlet temperatures too high Ensure proper use Chapter 2.4
Machine gets too hot p.33 ↗ Cooling air supply is obstructed Check ambient conditions Chapter 5.1
Machine gets too hot p.33 ↗ Cooling air supply is obstructed Clean ventilation slots Chapter 7.4
The machine makes a strange noise p.33 ↗ Deposits on the rotary piston Clean the working space and the rotary piston Elmo Rietschle Service