The 5200 Fragment Analyzer is a 12-capillary automated electrophoresis system for sizing, quantification and integrity assessment of IVT mRNA and DNA fragments. It is the 12-capillary member of the Fragment Analyzer series, distinguished by exclusive support for the 22 cm effective / 47 cm total capillary array. It serves as the QC instrument for IVT mRNA drug substances and CRISPR/NGS fragment analysis in biopharmaceutical process analytics.

Agilent Technologies Fragment Analyzer Systems Series — Model Comparison & Selection

Model Measurement rangePlate capacityAverage sizing of 2 200 nt ivt mrna, ntLower marker size of hs rna kit, ntMaximum ivt mrna sample size analyzed, ntSample volume per well, microliter
5200 Fragment Analyzer Current ——23701560002
5300 Fragment Analyzer ——2370156000—
Fragment Analyzer Capillary Arrays —12———2
RNA QC, DNA QC, Fragment Analyzer —12———2
Ultra-high-throughput fragment analysis 5400 Fragment Analyzer 0.5nine plates2370156000—

Full specifications

Core Performance & Functional Specifications
Accuracy 20 gram
Average Sizing Of 2,200 Nt Ivt Mrna 2370 nt
Gel Volume 10 mL
Intercalating Dye Volume 1.0 µL
Lower Marker Size Of Hs Rna Kit 15 nt
Maximum Ivt Mrna Sample Size Analyzed 6000 nt
Measured Concentration 431 pg/µL
Precision 15 %CV
Sample Volume Per Well 2 µL
Sizing range mfr 35 bp
Sizing precision mfr 5 %CV
Sizing accuracy mfr 10
Sample types analyzed mfr IVT mRNA drug substances and LNP-encapsulated IV
Additional sample mfr 1
Instrument mfr 5300 system
LNP disruption mfr varying amounts of surfactant surfactant
Surfactant levels tested mfr 20
Sample concentration range mfr 1 ng/μL
Extended method mfr Method BE BE
Dilution ratios tested mfr 1
Recommended sample concentration range mfr 1...100 ng/μL
Fragment Analyzer systems mfr 5200
DNA sizing range mfr 100 bp
Separation resolution mfr 10
DNA sizing precision mfr 2 % CV
DNA sizing accuracy mfr 5 better
DNA fragment concentration range mfr 0.005 DNA
Sizing precision (%CV) mfr 5 %CV
Sizing accuracy (%error) mfr 10
IVT mRNA drug product sizes analyzed mfr 2,200 nt
Surfactant concentrations tested for LNP disruption mfr 20
Sample concentration range assessed mfr 1 ng/μL
Dilution ratios assessed with extended method mfr 1
Instrument model mfr 5200
DNA sizing precision1 mfr 2 % CV
DNA sizing accuracy1 mfr 5 better
Inlet Buffer fill volume per well mfr 1.0 mL/well
Capillary Storage Solution fill volume per well mfr 1.0 mL/well
Marker plate fill volume per well mfr 30 μL/well
MDK DNA Ladder volume per well mfr 24 μL
Library dilution concentration mfr 500 pg/μl
Smear analysis region mfr 200...1,000 bp
disruption time mfr 20 minutes
sizing accuracy specification mfr 15 % error
sizing precision specification mfr 5 % CV
heat denaturation time mfr 2 minutes
plate vortex duration mfr two minutes minutes
pipette mixing volume mfr 20 μL
diluent marker volume per well mfr 22 μL
recommended sample concentration range mfr 1...100 ng/μL
Dimensions, Weight & Mechanical Design
Sample sizes (nucleotide length) mfr 2,200 nt
maximum peak height mfr 24000 RFU
Standards, Safety & General Data
RNA kit (15 nt) part number mfr -471
standard sizing upper limit mfr 6000 nt

Description

Construction and series positioning

Analytical behavior

Installation, control and operation

Integration & Operating Notes

Process Limits
Dilute DNA samples into 0.005–2 ng/µL before loading

Input DNA above 2 ng/µL saturates the specified concentration range of the CRISPR Discovery Gel Kit; dilute into range with the supplied dilution buffer (0.1x TE) so that sizing and quantification stay within the stated precision and accuracy.

CRISPR Discovery Gel Kit Quick Guide, Kit Specifications, page 1
Control & I/O
Method code must match the installed array variant

In the Fragment Analyzer software, select the CRP-910-(22, 33 or 55) CRISPR Discovery method corresponding to the physically installed array; a mismatched method invalidates resolution and sizing results. For 12-capillary runs, select Tray and Row before entering Sample ID and Tray ID.

CRISPR Discovery Gel Kit Quick Guide, Fragment Analyzer Software Operating Procedure, page 4
Process Limits
Prepare standards in 1x TE to hold ±5% sizing accuracy

The stated 2 %CV sizing precision and ±5% or better sizing accuracy apply only when DNA ladder or DNA fragment standards are initially prepared in 1x TE Buffer; other diluents shift migration and void the accuracy claim.

CRISPR Discovery Gel Kit Quick Guide, Kit Specifications, page 1
Maintenance
Ladder occupies well 12 of every analyzed row

Place 24 µL of ready-to-use MDK DNA Ladder undiluted into well 12 of each row of samples; plan plate layout so that well 12 is reserved, and fill marker plate row A at 30 µL/well with a mineral oil overlay.

CRISPR Discovery Gel Kit Quick Guide, Instrument and Sample Preparation, page 3

Selection & Integration Q&A

When should I choose the 5200 over the 5300 or 5400 Fragment Analyzer?

Pick the 5200 for 12-capillary workloads needing the 22 cm effective / 47 cm array, which is exclusive to the 12-capillary system and gives 10 bp resolution at 500 bp. Choose the 5300 for higher sensitivity (5 pg/µL) or LNP-encapsulated IVT mRNA CQA, and the 5400 for ultra-high throughput.

What capillary array and kit combination must be ordered with the 5200 for CRISPR fragment analysis?

Order a 12-capillary array in the 22, 33 or 55 variant plus the CRISPR Discovery Gel Kit (DNF-810 gel, DNF-600-U030 dye, DNF-355 inlet buffer, DNF-475 conditioning solution, markers, MDK ladder, dilution buffer, mineral oil). Capillary Storage Solution (GP-440-0100) is sold separately.

What are the daily and periodic maintenance steps required before a 5200 run?

Fill row A of the 1x 930 dsDNA Inlet Buffer tray at 1.0 mL/well and replace daily; place Capillary Storage Solution in row H at 1.0 mL/well and replace every 2–4 weeks. Fill marker plate row A at 30 µL/well with mineral oil overlay and load 24 µL undiluted MDK ladder in well 12 of each row.

Which consumables are not included in the base 5200 delivery and must be sourced separately?

The Capillary Storage Solution (GP-440-0100) is sold separately from the CRISPR Discovery Gel Kit. Gel, intercalating dye, inlet buffer, capillary conditioning solution, markers, MDK DNA Ladder, dilution buffer and mineral oil are kit components; capillary arrays and RNA/DNA QC kits are ordered per application.

Dimensional Drawings & Technical Documentation

Dimensional drawings

performance curve performance curve performance curve performance curve

Click drawing to inspect vector dimensions

Technical documentation

PDF
Not for use in diagnostic procedures
Manual ·4 pp.
View PDF
PDF
Quality Assessment of NGS
Brochure ·404,9 КБ ·5 pp.
View PDF
PDF
CQA Assessment of LNP-mRNA Drug Products
Brochure ·381,9 КБ ·7 pp.
View PDF
PDF
Best Practices for Analysis of IVT mRNA by Fragment Analyzer
Brochure ·946,9 КБ ·12 pp.
View PDF