Agilent Technologies 531 Thermocouple Gauge, Rough Vacuum Pressure Measurement
Agilent Technologies 531 Thermocouple Gauge, Rough Vacuum Pressure Measurement — Vacuum technologies.
The Agilent 531 is a thermocouple-type rough-vacuum gauge transducer for pressure measurement in the coarse vacuum regime. It is the thermocouple member of the Vacuum Transducers series, distinct from the Bayard-Alpert ionization tubes (571/572) and the cold-cathode 525 that cover high vacuum. It serves as the foreline/backing-line pressure sensor in a pump-down system.
Agilent Technologies Vacuum Transducers Series — Model Comparison & Selection
| Model | Measurement range | Atomic mass unit, grams | Electron charge, coulomb | Molar volume, liters | Max pressure, megapascal | Sensitivity |
|---|---|---|---|---|---|---|
| 531 Thermocouple Gauge, Rough Vacuum Pressure Measurement Current | — | 1.66 | 1602 | 22.41 | — | — |
| 571 Bayard-Alpert Gauge Tube | -3...2 | 1.66 | 1602 | 22.41 | 1.33×10⁻⁴ | 17 |
| 572 Tungsten Bayard-Alpert Gauge | -3...2 | 1.66 | 1602 | 22.41 | -3...2 | — |
| Cold Cathode Gauge Tube 525, High Vacuum (HV) Gauge | — | 1.66 | 1602 | 22.41 | — | — |
| Hot Filament Gauge MBA2-201, Ionization BA Gauge | — | 1.66 | 1602 | 22.41 | — | — |
| IMG-100 Inverted Magnetron Gauge | — | 1.66 | 1602 | 22.41 | — | — |
| IMG-300 UHV Inverted Magnetron Gauge | — | 1.66 | 1602 | 22.41 | — | — |
| UHV-24/UHV-24p | 1 | 1.66 | 1602 | 22.41 | — | 25 |
Full specifications
| Electron Charge | 1.602 coulomb |
| Molar Volume | 22.41 liters |
| Acceleration due to gravity mfr | 9.8066 |
| Angstrom unit mfr | 10 m |
| Avogadro's number mfr | 6.02214076 |
| Boltzmann's constant mfr | 1.38064852 |
| Equivalent of heat mfr | 4.185 |
| Natural log base mfr | 2.7183 |
| Velocity of light mfr | 2.9979 |
| Velocity of sound mfr | 343 |
| Magnetic flux density mfr | 1 |
| Pressure conversion mfr | 1 Torr |
| Pumping speed conversion mfr | 1 L/s |
| Throughput conversion mfr | 1 cc/sec |
| Outgassing rate mfr | 2 |
| Atomic Mass Unit | 1.6605 grams |
| Standard pressure mfr | 101325 Pa |
Description
Construction and series positioning
- The 531 is a thermocouple gauge: a heated filament whose temperature, and therefore thermocouple output, depends on gas density in the rough-vacuum range.
- Within the series it is the rough-vacuum instrument; the 571 and 572 Bayard-Alpert tubes and the 525 cold-cathode tube are high-vacuum ionization gauges and are not interchangeable with it.
- The 536 baffled thermocouple gauge is the sibling variant of the same sensing principle, adding a baffle.
Measurement behavior
- Thermocouple gauges respond to gas composition as well as pressure; readings are conventionally referenced to nitrogen/air and shift for other gases.
- The supplied reference booklet provides the conversion and gas-property tables (pressure units, throughput, pumping-speed and outgassing-rate conversions) used to interpret and cross-check such readings.
- No digitized response curve was supplied for this model, so no accuracy or response-time figures are stated here.
Installation and operation
- The attached documents are portfolio and reference brochures; they contain no 531-specific installation, connection or control instructions. Wiring, flange and controller requirements must therefore be taken from the model's own instruction manual, which was not among the supplied digests.
Integration & Operating Notes
Thermocouple sensing is intended for coarse vacuum and foreline pressures; for high-vacuum measurement the series provides the 571/572 Bayard-Alpert and 525 cold-cathode tubes. Selecting the 531 for a high-vacuum chamber will not give usable readings and the wrong gauge family must be avoided at the design stage.
Thermocouple gauge output depends on the thermal conductivity of the gas present, so a reading calibrated for nitrogen/air will differ in helium, hydrogen or other process gases. Use the gas-property and conversion tables in the Agilent formulas and tables booklet to interpret readings rather than taking the displayed value as absolute pressure.
The supplied documents are portfolio and reference brochures and contain no 531-specific supply voltage, signal output or cable specification. Do not size the controller or cabling from this card; obtain the electrical interface from the 531 instruction manual before wiring the transducer into a system.
Thermocouple gauge tubes are exposed to the foreline environment and are normally treated as serviceable/replaceable items; the portfolio brochure lists spare parts and service options but gives no 531-specific interval. Establish the replacement interval from observed drift in your process rather than assuming a fixed schedule.
Selection & Integration Q&A
Pick the 531 for rough-vacuum and foreline pressure, where thermocouple sensing is appropriate. Choose the 571 or 572 Bayard-Alpert tubes or the 525 cold-cathode tube when the measurement point is high vacuum; those ionization gauges are a different family and are not substitutes for the 531.
The supplied brochures give no 531-specific supply voltage, output signal or cable data, so the controller, cable and connector must be matched from the 531 instruction manual. Confirm the gauge's electrical interface before ordering the readout electronics; do not infer it from the series portfolio literature.
No 531-specific mounting orientation, ambient temperature or duty-cycle limits are stated in the supplied documents, which are portfolio and reference brochures only. Obtain these from the 531 manual before fixing the gauge location; the reference booklet's conversion tables do not substitute for installation limits.
The portfolio brochure lists spare parts and service options but no 531-specific interval; treat the gauge tube as a replaceable item and set replacement from observed drift. Controller, cable and readout electronics are separate items and are not part of the base gauge delivery.