No photo available yet
Agilent Technologies 708-DS Dissolution Apparatus
Agilent Technologies 708-DS Dissolution Apparatus — Dissolution testing with Pumping speed 3×10⁻⁵ m³/h, Temperature 37 °C.
The Agilent 708-DS is a 6-position (G7910A) or 8-position (G7911A) dissolution apparatus with a 1 L vessel volume and motorized drive unit lift. It operates at 37 °C with spindle speeds of 10–250 RPM and a water bath range of ambient +5 to 55 °C. It is used for USP Apparatus 1 and 2 dissolution testing with optional automated sampling and online HPLC analysis.
Agilent Technologies Dissolution Apparatus Series — Model Comparison & Selection
| Model | Temperature, °C | Coverslip type | Weight, kg | Operating altitude, m | Pumping speed, m³/h | Operating temperature, °C |
|---|---|---|---|---|---|---|
| 708-DS Dissolution Apparatus Current | 37 | 0.1 | 54.4 | 2000 | 3×10⁻⁵ | — |
| 400-DS Apparatus 7 | Delayed Start | Use the drop-down arrows | 59 | 2000 | — | 55 |
Full specifications
| Pumping speed | 0.5 mL/min |
| Temperature | 37 °C |
| Column temperature | 50 °C |
| Coverslip type | 0.1 mL |
| Filter Pore Size | 10 μm |
| Full Flow Filter Pore Size | 10 μm |
| Paddle Volume | 1 L |
| Printer | Optional internal thermal printer |
| Sample volume | 5 µL |
| Syringe Filter Pore Size | 0.45 μm |
| Vessel Volume | 1 L |
| Vial Volume | 2 mL |
| Dissolution medium mfr | 0.1 mL |
| Stirring rate mfr | 75 rpm |
| Needle wash mfr | 3 s |
| Max-Light cartridge cell (DAD 1) mfr | 60 mm |
| Max-Light cartridge cell (DAD 2) mfr | 3.7 mm |
| Basket mesh mfr | 40 mesh |
| Thermal printer paper pack size mfr | 10 rolls/pk |
| Safety standards mfr | IEC, EN, CSA, UL UL |
| Evaporation mfr | 1 conditions |
| Spindle - Speed range mfr | 10 RPM |
| Spindle - Speed Accuracy mfr | 1 RPM |
| Spindle - Speed Selection mfr | Via touch screen screen |
| Sampling mfr | Manifold option available for automated sampling |
| Drive unit lift mfr | Motorized drive drive |
| Optional features mfr | Manual drive unit lift, Dosage Delivery Module , |
| Instrument Control via PC mfr | 1.7 |
| Maintenance and safety-related features mfr | Spindle hours are tracked in FW FW |
| GLP features mfr | Errors can be tracked via print-out or in the so |
| Housing mfr | All materials are recyclable recyclable |
| Solvents mfr | A) Water B) Acetonitrile Acetonitrile |
| Paracetamol content mfr | 200 mg |
| Caffeine content mfr | 25 mg |
| Chlorphenamine content mfr | 2.5 mg |
| Complete dissolution stirring time mfr | 90 minutes |
| Syringe filter diameter mfr | 25 mm |
| Vial dimensions mfr | 12 mm |
| Cap size mfr | 12 mm |
| Condition mfr | Performance may vary depending on environmental |
| Spindle Speed mfr | 10.0 RPM |
| Test Duration mfr | 10...999 |
| Final Spin Duration mfr | 10...001 |
| Tester ID mfr | 12 characters |
| Comm ID mfr | 01...99 |
| Sample Point Alarm mfr | 05...000 |
| Number Active mfr | Sets the number of vessels used in a test. The r |
| Weight | 54.4 kg |
| Upper receptor shaft length mfr | 21 in. |
| Bent cannula gauge length mfr | 7.75 in. |
| Dimensions (height × width × depth) mfr | 680 mm |
| Cannula gauge length mfr | 7.75 in. |
| Capsule weight wire length mfr | 50 ft. |
| Cannula length mfr | 7.75 in. |
| Line voltage mfr | 115 |
| Line frequency mfr | 60 Hz |
| ISM Classification mfr | 1 A |
| Power consumption mfr | 10.0 A |
| Needle Wash mfr | 3 A |
| Local User Interface mfr | LCD display with integral touch screen screen |
| Serial Number mfr | 15 characters |
| Capsule weight wire diameter mfr | 0.032 in. |
| Spindle shaft material mfr | Stainless steel steel |
| Dissolution media volume mfr | 900 mL |
| Media Volume mfr | 100...2000 mL |
| Operating Altitude | 2000 m |
| Humidity mfr | 80 % r.h. |
| Water bath - Probe accuracy mfr | 0.1 °C |
Description
Construction and series positioning
The 708-DS is a benchtop dissolution apparatus available in two configurations: the 6-position G7910A and the 8-position G7911A. It uses 1 L vessels and supports USP Apparatus 1 (rotating basket, 40-mesh) and Apparatus 2 (rotating paddle). The drive unit lift is motorized as standard, with a manual lift option. The unit weighs 54.4 kg dry and measures 680 × 622 × 590 mm (H × W × D). Within the Agilent dissolution series, the 708-DS is the standard multi-position apparatus, while the 400-DS Apparatus 7 and BIO-DIS are reciprocating cylinder systems for extended-release and special dosage forms, and the NanoDis System is for nanoparticle dissolution.
Behavior under load and media
Spindle speed is selectable from 10 to 250 RPM via the touch screen, with accuracy of ±1% above 25 RPM and ±2% from 10 to 25 RPM. The water bath maintains ambient +5 to 55 °C with probe accuracy of ±0.1 °C; the dissolution medium is typically held at 37 °C. The bath temperature probe has a resistance of 2252 Ω at 25.0 °C and 1355 Ω at 37.0 °C, allowing field verification with an ohmmeter. The heater/circulator must never be turned on before the bath is filled with purified water to the correct level.
Installation, control and operation
Line voltage is 115/230 V~ ±10% at 60/50 Hz with no external voltage selector or accessible fuses; power consumption is 2.0/1.0 A without heater and 10.0/5.0 A with the Wide Input Range Heater. The instrument requires 10 cm clearance on either side, 20 cm at the rear, and 30 cm above when fully raised. It operates in ambient 5–40 °C and up to 80% RH non-condensing, indoors up to 2000 m altitude. Control is via LCD touch screen or PC software (Dissolution Workstation 1.7+, Cary WinUV Dissolution 5.3+, Dissolution Workflow Manager 1.0 SR1). Optional features include Dosage Delivery Module, automated sampling manifold, AutoTemp, resident sampling cannulas, handheld temperature probe, and internal thermal printer.
Integration & Operating Notes
The Wide Input Range Heater draws up to 10.0 A at 115 V (5.0 A at 230 V), while the base instrument draws 2.0/1.0 A. Size the branch circuit and any UPS for the heater-inclusive current, and note that protection is electronic and internal—no externally accessible fuses are provided.
The dry weight with vessels and paddles is 54.4 kg. Provide 10 cm clearance on either side, 20 cm at the rear, and at least 30 cm above the unit when fully raised for ventilation and access to liquid and electrical connections. Operating height is 680 mm; clearance height is 991 mm.
The water bath temperature range is ambient +5 to 55 °C. Setpoints below ambient +5 °C are not supported. For 37 °C dissolution testing, ensure the ambient temperature does not exceed 32 °C to stay within the bath's control range.
Retaining ties secure the drive unit during shipment. They must be removed before turning on the instrument; failure to do so can cause significant damage during the initialization self-test. Verify removal before first power-up and after any relocation.
Every six months, lubricate the linear bearing upright supports with 3-in-1 oil and inspect the spindle drive belt for wear, fraying, and tension. These tasks can be performed without opening the main cover. Maintenance intervals may vary with instrument usage.
When a sampling manifold is configured, flush the sample tubing after every test using a rinse tubing kit (17-1341) or rinse tray. Routine rinsing prevents carryover and blockage. Corrosive media require immediate rinsing with deionized water; laboratory dishwashers must not be used for shafts, baskets, or sample lines.
Selection & Integration Q&A
Choose the 708-DS for standard USP Apparatus 1 (basket) or 2 (paddle) dissolution testing with 1 L vessels, available in 6-position (G7910A) or 8-position (G7911A) configurations. The 400-DS Apparatus 7 and BIO-DIS are reciprocating cylinder systems for extended-release or special dosage forms; the NanoDis System is for nanoparticle dissolution.
The 708-DS accepts 115/230 V~ ±10% at 60/50 Hz with no external voltage selector and no externally accessible fuses. Power draw is 2.0/1.0 A without heater and 10.0/5.0 A with the Wide Input Range Heater. Provide an external branch circuit rated for the heater-inclusive current; internal protection is electronic.
Bi-annual maintenance includes lubricating linear bearing upright supports with 3-in-1 oil and inspecting the spindle drive belt. Consumables not included: rinse tubing kit (17-1341) or rinse tray for sample lines, thermal paper rolls (58 mm wide × 13.65 m max) for the optional printer, and replacement temperature probes (tolerance ±0.2 °C).