Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies GC autosampler, GC sample injection

Agilent Technologies GC autosampler, GC sample injection — Gas chromatography.

The 7693A is a tower-mounted automatic liquid sampler for Agilent 8890/8860 GC systems, delivering 1 µl injections from a 5 µl syringe through a split/splitless inlet at 250 °C. It is the standard ALS in the 7693 series, distinguished from the 7650A by its injector tower configuration and from the 7697A/8697 headspace samplers by handling only liquid samples.

Agilent Technologies GC Sample Preparation Introduction Series — Model Comparison & Selection

Model Sample volume, milliliterAnalysis time, minBake flow, mL/minBake temperature, °CBake time, minCalibration concentration, µg/ml
GC autosampler, GC sample injection Current 0.00180———100
PAL3 autosampler, automated solid phase extraction ——————
purge and trap, volatile organic compounds analysis ——2002802—
Reliable, consistent GC introduction of liquefied gases ——————

Full specifications

Core Performance & Functional Specifications
Analysis time 80 min
Calibration Concentration 100 µg/ml
Oven Temperature Ramp 5 °C/min
Retention Time, 1-butanol 11.43 min
Retention Time, 2-butanol 7.88 min
Retention Time, Ethylacetat 4.51 min
Retention Time, Ethylbutyrat 8.09 min
Retention Time, Ethylhexanoat 13.88 min
Retention Time, Ethyllactat 16.93 min
Retention Time, Isoamylalkohol 13.25 min
Retention Time, Isobutanol 9.96 min
Retention Time, Methanol 4.75 min
Retention Time, N-propanol 8.26 min
Sample volume 1 µl
Split Flow 30 ml/min
Syringe Volume 5 µl
GC system mfr 8890 GC
Detector mfr FID FID
Autosampler mfr 7693 ALS
Split ratio mfr 20
Liner mfr Split, Ultra inert, glass wool, low pressure pre
Carrier gas mode mfr constant pressure pressure
Sample solvent mfr hexane hexane
Sample concentration mfr 50...100 ng/μl
FAME mix concentration range mfr 200...400 ng/μl
RF RSD mfr 4
Maximum component deviation mfr 4.0
Syringe size mfr 10 μl
Inlet type mfr Split/Splitless Split/Splitless
Inlet mode mfr Split Split
Gas saver time mfr Aus Aus
High vacuum pump mfr Turbo Turbo
Acquisition mode mfr Scan Scan
Scan range mfr 40 m/z
Tuning algorithm mfr Etune Etune
GC/MS flow requirement (EPC capability) mfr 2 ml/min
Dimensions, Weight & Mechanical Design
Component weight percent range mfr 3...30
Operating Conditions, Environment & Protection
Inlet Temperature 250 °C
Quadrupole Temperature 175 °C
Source Temperature 250 °C
Standards, Safety & General Data
Standard Stock Solution Concentration 1000 µg/ml
Number of compounds in standard mfr 28

Description

Construction and series positioning

Behavior under method conditions

Installation, control and operation

Integration & Operating Notes

Mounting
Tower must align with the split/splitless inlet on the GC

The 7693A injects through the S/SL inlet, so the tower position and syringe guide are set for that inlet geometry; fitting it to a different inlet type or a different GC platform requires the matching mounting hardware and re-alignment before the first injection.

Application Notes 5994-0490DE, 5994-0549DE, 5994-0486DE
Process Limits
Injection volume must stay within the installed syringe size

Documented methods use 1 µl injections from a 5 µl syringe or a 10 µl syringe; the injected volume, syringe size and inlet split ratio must be chosen together, because a volume too large for the syringe or the liner will cause carryover or inlet flooding rather than a valid result.

Application Note 5994-0490DE; Application Note 5994-0549DE
Cooling & Media
Carrier gas is run at constant pressure with gas saver off

The documented methods use constant-pressure carrier-gas mode and leave gas saver disabled, so the inlet consumes carrier gas for the entire 80-minute run; the gas supply and purity chain must be sized for continuous flow over the full sequence, not just the injection window.

Application Note 5994-0490DE
Maintenance
Syringe and liner are consumables selected per method

The 5 µl or 10 µl syringe and the split, ultra-inert, glass-wool low-pressure liner are method-specific consumables; they wear with each injection and must be replaced on the laboratory's preventive schedule, and neither is defined as part of the base sampler delivery in the digests.

Application Note 5994-0490DE; Application Note 5994-0549DE
Control & I/O
Sampler operation is driven from the GC method

Injection volume, split flow and inlet temperature are set in the GC method that also controls the 8890/8860 and the 5977 MSD; the sampler has no separate method editor described in the digests, so method validation covers the sampler and GC together.

Application Notes 5994-0490DE, 5994-0549DE, 5994-0486DE

Selection & Integration Q&A

When should I choose the 7693A instead of the 7650A or a 7697A/8697 headspace sampler?

Pick the 7693A for direct liquid injection through a split/splitless inlet, as in the distilled-spirits, FAME and forensic methods. Choose the 7697A or 8697 when analytes must be volatilized from the matrix by headspace; the 7650A is the alternative ALS variant in the same family.

What must the GC inlet and carrier-gas supply provide for this sampler?

A split/splitless inlet with a split, ultra-inert, glass-wool low-pressure liner, run at 250 °C in constant-pressure mode with gas saver off; the documented split flow is 30 ml/min at split ratio 20, so the carrier-gas supply must sustain that flow for the full 80-minute run.

Which parts of the injection path are consumables or accessories not included in the base sampler?

The syringe (5 µl in the spirits method, 10 µl in the FAME method) and the split, ultra-inert, glass-wool low-pressure liner are method-specific items; the digests do not list them as part of base delivery, so they must be ordered and replaced on the laboratory's preventive-maintenance schedule.

Dimensional Drawings & Technical Documentation

Technical documentation