Agilent Technologies Analytical HPLC and UHPLC Systems
Agilent Technologies Analytical HPLC and UHPLC Systems — Liquid chromatography.
The Agilent InfinityLab analytical HPLC/UHPLC system is a modular liquid chromatography platform built around a 4.6 mm internal-diameter column format and a typical flow rate of 1 mL/min. It is the standard analytical-scale configuration of the InfinityLab series, distinguished from the 2D-LC, bio-inert, GPC/SEC and application-specific siblings by its conventional analytical column dimension. It serves as the primary separation and quantitation front end for routine small-molecule analysis in a chromatography workflow.
Agilent Technologies HPLC Systems Series — Model Comparison & Selection
| Model | Max pressure, megapascal | Carryover, % | Column inner diameter, mm | Maximum pressure, bar | Sample capacity | Typical flow rate, mL/min |
|---|---|---|---|---|---|---|
| Analytical HPLC and UHPLC Systems Current | — | 9×10⁻⁴ | 4.6 | 1300 | 6144 | 1 |
| 2D-LC System | 130 | 9×10⁻⁴ | 4.6 | 1300 | 6144 | 1 |
| GPC/SEC Systems, Macromolecular Analysis and Solution | — | 9×10⁻⁴ | 4.6 | 1300 | 6144 | 1 |
| Preparative HPLC Systems, InfinityLab LC Purification Solutions | — | 9×10⁻⁴ | 4.6 | 1300 | 6144 | 1 |
Full specifications
| Carryover | 9 ppm |
| Maximum pressure | 1300 bar |
| Sample Capacity | 6144 samples |
| Typical Flow Rate | 1 mL/min |
| Productivity range mfr | Micrograms Micrograms |
| Column Inner Diameter | 4.6 mm |
Description
Construction and series positioning
- Modular analytical-scale LC platform using 4.6 mm internal-diameter columns, the conventional analytical format; the 2D-LC, Bio HPLC/Bio-Inert, GPC/SEC and application-specific siblings are separate configurations for multidimensional, biological, macromolecular or dedicated assays.
- Sample capacity of 6144 samples and carryover of 9 ppm define the autosampler duty envelope for this analytical modification.
- The product line spans analytical, bio and preparative configurations; this card covers only the analytical HPLC/UHPLC modification.
Behavior and performance envelope
- Typical operating flow rate is 1 mL/min at the 4.6 mm column diameter, the standard analytical-scale condition.
- Carryover of 9 ppm sets the residual-sample level to account for when low-concentration analytes follow high-concentration injections.
- Productivity range is stated in micrograms; no further quantitative performance data (pressure limits, gradient performance, detector specifications) are available in the verified facts.
Installation, control and operation
- The attached brochures cover the InfinityLab LC portfolio (2D-LC, Bio LC, purification) and do not contain model-specific installation, connection or control facts for this analytical configuration; no electrical, interface or environmental specifications are verified for this model.
- No digitized curve points or certificates are available; performance claims beyond the listed specifications cannot be supported.
Integration & Operating Notes
Residual carryover of 9 ppm means a high-concentration injection can leave a detectable residue in the following run. Sequence high-concentration samples after low-level ones, or insert blank/wash injections, when quantitating near that level.
The verified facts contain no voltage, current, communication-interface or controller specifications for this analytical configuration. Electrical and I/O requirements must be taken from the instrument's own site-preparation and installation documentation before integration.
Selection & Integration Q&A
Choose this analytical modification for conventional small-molecule separations on 4.6 mm ID columns at about 1 mL/min. Select the 2D-LC sibling for multidimensional separations, the Bio/Bio-Inert sibling for biological samples, and the GPC/SEC sibling for macromolecular molecular-weight work.
Columns must be 4.6 mm internal diameter to match the analytical flow regime of about 1 mL/min. No verified data exist for pump pressure rating, detector, autosampler interface or controller, so those must be confirmed from the instrument's own site-preparation documentation.
The verified facts contain no ambient temperature, humidity, altitude or bench-loading specifications for this analytical configuration. Installation environment and duty-cycle limits must be taken from the instrument's site-preparation guide; the attached portfolio brochures do not state them.
No service intervals, spare parts or consumable lists are verified for this model. Plan column and wear-part replacement from the instrument's maintenance manual; the attached brochures cover the 2D-LC, Bio LC and purification portfolios and do not define analytical-system consumables.