Agilent Technologies Bond Elut Lipid Extraction
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Bond Elut Lipid Extraction

Agilent Technologies Bond Elut Lipid Extraction — Sample preparation.

Bond Elut Lipid Extraction is a 1 mL SPE cartridge with EMR—Lipid sorbent for plasma, cell culture and tissue samples. It uses 100 µL plasma and 900 µL crashing solvent (9:1 ratio, 5% MeOH recommended), then wash and elute. It removes lipids before LC-MS or GC-MS analysis of small molecules.

Agilent Technologies Bond Elut Series — Model Comparison & Selection

Model Pumping speed, m³/hSample volume, milliliterDrying gas temperature, °CAverage recovery all compounds, %Cartridge sorbent mass, mgCentrifugation speed, rpm
Bond Elut Lipid Extraction Current 3...5—30———
Bond Elut Carbon S & Carbon S/NH2 0.0240.00523099.21501900
Bond Elut HLB | SPE Sorbent 1.8×10⁻⁵0.0024073.4...118500—
Bond Elut LMS | Large Molecule Size —0.005———2800

Full specifications

Core Performance & Functional Specifications
Pumping speed 3...5 drop
Crashing Solvent Volume 900 μL
Plasma Sample Volume 100 μL
Recommended Flow Rate 3...5 drop
Reconstitution Volume 100 µL
Cartridge format mfr 1 mL
Sorbent chemistry mfr EMR—Lipid Lipid
Sample types mfr plasma, cell cultures, tissue samples samples
Washing solvent mfr 10...20 % water
Elution solvent mfr 1 % MeOH
Recommended elution solvent mfr DCM/MeOH or chloroform/MeOH v/v v/v
Vortex time mfr 30 seconds
Sonicate time on ice mfr 10 minutes
Wash volume mfr 2 mL
Plate format mfr 96 plate
Recommended crashing solvent mfr 5 % MeOH
Crashing solvent to sample ratio mfr 9
Minimum MeOH content for elution mfr 50
Collection plate volume mfr 2 mL
Sonicating time mfr 10 minutes
Wash solvent volume mfr 2 mL
Elution volume mfr 2 mL
Crashing solvent composition mfr 1...5 % MeOH
Washing solvent composition mfr 10...20 % water
Elution solvent composition mfr 1 % MeOH
Vortex duration mfr 30 seconds
Sonicate duration on ice mfr 10 minutes
Reconstitution vortex duration mfr 2 minutes
Reconstitution sonicate duration mfr 10 minutes
Crashing solvent/plasma ratio mfr 9 v/v
Minimum aqueous content in sample mixture for loading mfr 10
Agilent Bond Elut Lipid Extraction, 1 mL cartridge mfr 100 pk
Agilent Bond Elut Lipid Extraction, 96-well plate mfr 5 plates
crashing solvent MeOH content mfr 1...5
washing solvent water content mfr 10...20
minimum MeOH in elution solvent mfr 50
vortex time mfr 30 seconds
sonication time on ice mfr 10 minutes
wash volume mfr 2 mL
elution volume mfr 2 mL
reconstitution sonication time mfr 10 minutes
minimum aqueous content in sample mixture mfr 10
Electrical, Power & Drive Specifications
96-well plate variant mfr 96 w
Operating Conditions, Environment & Protection
Drying Gas Temperature 30 °C
Storage temperature 20 °C

Description

Construction and series positioning

Working range and media

Operation

Integration & Operating Notes

Process Limits
Crashing solvent must stay at 1–5% MeOH for precipitation

The method specifies 1–5% MeOH in the crashing solvent, with 5% recommended, at a 9:1 solvent-to-sample ratio (900 µL to 100 µL plasma). Deviating outside this window changes protein precipitation and lipid binding, so the solvent must be prepared and verified before loading.

Factory Specification Sheet; Method Guide 1 mL Cartridge, 5994-1627EN
Process Limits
Elution needs at least 50% MeOH in the elution solvent

Lipid elution requires a minimum MeOH content of 50%; recommended elution solvents are DCM/MeOH or chloroform/MeOH at 1 mL. A lower-MeOH eluent will not quantitatively release retained lipid, so solvent composition must be checked before use.

Factory Specification Sheet
Sample Prep
Vortex 30 s and sonicate 10 min on ice before loading

The documented protocol requires 30 s vortexing followed by 10 min sonication on ice after adding crashing solvent. Skipping or shortening these steps leaves incomplete protein precipitation and can foul the sorbent bed, so they must be scheduled into the batch workflow.

Factory Specification Sheet; Method Guide 1 mL Cartridge, 5994-1627EN
Mounting
1 mL cartridge and 96-well plate are separate formats

This model is the 1 mL cartridge; the 96-well plate variant (5610-2042) uses a 2 mL collection plate and its own method guide (5994-1690EN). Vacuum manifolds and collection racks must match the chosen format; the two are not interchangeable on the same hardware.

Method Guide 96-Well Plate, 5994-1690EN

Selection & Integration Q&A

When should I choose the 1 mL cartridge instead of the 96-well plate variant?

Pick the 1 mL cartridge for low-to-medium sample counts and method development, where individual cartridges are processed on a vacuum manifold. Choose the 96-well plate (5610-2042) for higher-throughput batches; it uses a 2 mL collection plate and the separate 5994-1690EN method.

What adjacent hardware and solvents must be in place before running this cartridge?

A vacuum SPE manifold accepting 1 mL cartridges, a 2 mL collection tube or plate position, and prepared solvents: crashing solvent at 1–5% MeOH (5% recommended), 10–20% water wash, and DCM/MeOH or chloroform/MeOH eluent with at least 50% MeOH. Vortex and ice-bath sonicator are also required.

What sample and solvent volumes does the protocol fix, and what happens if I scale them?

The method fixes 100 µL plasma to 900 µL crashing solvent (9:1), a 2 mL wash and 1 mL elution. Scaling changes the ratio and the minimum 50% MeOH elution condition; revalidate recovery and lipid removal before altering volumes.

What is not included in the base delivery and what consumables must be ordered separately?

The cartridge is supplied as the SPE device only; collection tubes or the 2 mL collection plate, vacuum manifold, vortexer, sonicator and all solvents (MeOH, water, DCM, chloroform) are not part of the delivery and must be sourced separately.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Agilent Bond Elut Lipid Extraction Protocol
Manual ·825,1 КБ ·2 pp.
View PDF