Agilent Technologies FTIR Spectroscopy Equipment
Agilent Technologies FTIR Spectroscopy Equipment — Molecular spectroscopy.
The Agilent 4200 FlexScan is a handheld FTIR spectrometer for onsite molecular analysis, covering 5100–600 cm⁻¹ with a single-reflection ATR interface. Its 2.6 µm effective pathlength and 2.5 mm ATR surface suit direct contact sampling of liquids and solids with minimal preparation. At 3.8 kg, it is positioned as the field-portable entry in the FlexScan/4300/4500/5500 series, distinguished by its handheld format rather than benchtop or compact configurations.
Agilent Technologies Molecular Spectroscopy Series — Model Comparison & Selection
| Model | Wavelength range | Sample volume, milliliter | Absorbance error, % | Atr path length, µm | Atr surface diameter, mm | Certified absorbance value of filter |
|---|---|---|---|---|---|---|
| FTIR Spectroscopy Equipment Current | 5100...600 | 0.02 | — | 2.6 | 2.5 | — |
| Fluorescence Spectroscopy Instrumentation, Spectrofluorometers | 900 | — | — | — | — | — |
| LDIR Chemical Imaging, IR & Imaging Spectroscopy | — | — | — | — | — | — |
| UV-Vis & UV-Vis-NIR Spectroscopy, Cary Instruments | — | — | 0.189 | — | — | 0.369 |
Full specifications
| Wavelength range | 5100...600 |
| Atr Surface Diameter | 2.5 mm |
| Effective Pathlength | 2.6 μm |
| Optical Aperture | 25 mm |
| Sample volume | 20 µL |
| Bench space required mfr | 20 cm |
| ATR spectral range mfr | 5100...600 |
| Spectrometer Body mfr | Glass-fiber reinforced polyamide for durability |
| Detector mfr | High-sensitivity thermoelectrically cooled deute |
| Interferometer mfr | 45 aperture |
| Bench space mfr | 20 cm |
| Spectral range (KBr optics) mfr | 7000...350 |
| Spectral range (ZnSe optics) mfr | 5100...600 |
| DialPath path lengths mfr | 30...1,000 microns |
| Atr Path Length | 2.6 μm |
| Weight | 3.8 kg |
| Weight range | 3.5 kg |
| ATR effective path length mfr | 36.5 |
| Footprint mfr | 26.4 module |
| ATR effective pH range mfr | 1...14 |
| ATR pH range mfr | 5...9 |
Description
Construction and series positioning
- The 4200 FlexScan is the handheld member of Agilent's FlexScan/4300/4500/5500 FTIR family; the 4300 is also handheld, while the 4500 and 5500 are portable/compact benchtop units. Choose the 4200 when true field portability and direct-contact ATR sampling are required; step up to the 4500/5500 when bench stability or additional sampling modules are needed.
- Sampling is via a single-reflection ATR element with a 2.5 mm surface diameter and 2.6 µm effective pathlength, giving a fixed, reproducible path without a transmission cell.
- The optical aperture is 25 mm, and the instrument weighs 3.8 kg with a 20 cm bench footprint when docked.
Spectral behavior and sample compatibility
- The spectral range is 5100–600 cm⁻¹, covering the mid-IR fingerprint and higher-wavenumber region; the ATR element is rated for pH 5–9, so strongly acidic or alkaline samples must be avoided or isolated from the crystal.
- The 20 µL sample volume indicates suitability for small liquid aliquots and contact deposits; no curve points or load-dependent behavior data are available for this model, so performance under varying contact pressure is not characterized here.
Installation and operation
- The attached document digests describe the Cary 635 benchtop FTIR and its interchangeable ATR/DialPath/TumblIR modules, not the 4200 FlexScan itself; no installation, control, or connection specifics for the handheld unit are present in the supplied facts. Integration details below are therefore limited to what the verified specifications support.
Integration & Operating Notes
The ATR element is rated for pH 5–9. Samples outside this window can attack the crystal and degrade the effective pathlength; neutralize or dilute aggressive samples before contact, and clean the crystal immediately after each measurement.
The specified 20 µL sample volume reflects the amount needed to fully cover the 2.5 mm ATR surface. Underfilling leaves part of the evanescent field sampling air, which weakens absorbance and skews library matching.
Because sampling is direct-contact ATR with a fixed 2.6 µm pathlength, residue on the 2.5 mm crystal surface directly biases subsequent spectra. Wipe with a solvent compatible with the crystal and the pH 5–9 window before the next measurement.
Selection & Integration Q&A
Pick the 4200 when true handheld field use and direct-contact ATR sampling are the priority. The 4300 is also handheld; the 4500 and 5500 are portable/compact benchtop units, better suited when bench stability or additional sampling modules are needed. The supplied facts do not give performance differences beyond format.
The 4200 uses a built-in single-reflection ATR element with a 2.5 mm surface diameter and 2.6 µm effective pathlength, so no external flow cell or transmission accessory is required. Samples must be compatible with the pH 5–9 crystal rating and provide at least 20 µL for full surface coverage.
The verified facts give weight (3.8 kg) and a 20 cm bench footprint but no operating temperature, humidity, or duty-cycle ratings. The only process limit stated is the ATR pH range of 5–9. Confirm environmental ratings with Agilent before committing to outdoor or high-humidity deployment.
Routine maintenance is cleaning the ATR crystal after each contact, keeping samples within pH 5–9. The supplied facts list no cables, calibration standards, or replacement ATR crystals as included; the attached digests cover Cary 635 benchtop accessories, not 4200 FlexScan consumables, so confirm the delivery scope with Agilent.